Switches & Buttons

Function switch

This switch selects the functions HEAT, OFF and 5 C.

HEAT 

Select this position to control the heating system, In AUTO 
mode the thermostat refers to the user programmed data to 
control the temperature. In Manual Mode the current set 
temperature will be maintained indefinitely.

OFF

This Position switches off the heating system.

5 C

 

This function ensures the home temperature does not fall 
below 5C. This prevents the home from freezing.

Filter button

The thermostat keeps a record of the number of hours your 
heating system has been running. This value is then displayed 
so that you may clean the filter if installed.
The 

Microstat

 will display the total number of hours the system 

has been ON and after 250 hours of system operation, the 
FILTER indicator will begin flashing to remind you to change or 
clean the filter. 

The filter counter will count up to a maximum of 999 hours and 
stays there until reset. 

To  reset the counter, press and hold the FILTER 

key until the display shows 000.

Programming

NOTE: The 

Microstat 

will automatically resume normal 

operation after 10 seconds of the last key press during 
programming. It is therefor important that during programming 
mode you do not wait for longer than 10 seconds between 
steps or the 

Microstat

 will exit programming mode requiring you 

to start the programming process from the beginning.

NOTE: Pressing the RETURN key will exit programming mode 
immediately.

Time and Day adjustment

In the normal mode, press DAY HOUR and MIN keys to set the 
day and time of day. Each press of the respective button will 
advance the value by 1hour, 1 minute or 1 day.

Default programs

 

The 

Microstat

 has four (4) pre-programmed heating programs 

for weekdays and two (2) for weekends. You can modify these 
programmes to suit your requirements.

Programming Method

 

Place the function switch to the HEAT position.
 
Press the PROG key. The display shows the program’s starting 
time and temperature set point. The Monday to Friday indicator 
will turn on indicating that this program is associated to the 
days of the week. 

The program number 1 will flash indicating the selected 
program. Adjust the program time by pressing the HOUR and 
MIN buttons, and the required temperature for that time by 
pressing the Temperature UP or Temperature Down button.

Pressing the PROG key again will allow you to scroll through 
the weekday programs 1 ~ 4 and weekend programs 1 ~ 2.

To Modify and Existing Program

Select the program to be modified by using the PROG key to step 
through to the required program (SA SU 1 for example).
Press the HOUR and MIN keys to modify the program’s starting time 
and the temperature up or temperature down buttons to set the 
desired temperature required at that time.
Press the RETURN key or wait 10 seconds for the automatic resume 
function.

Hint:

 To program the system to be off, while at work for example, 

programme the heating temperature to 5 deg C. 

Temperature span adjustment

The factory set temperature span is 1C. For example, if the 
temperature set point is 20C, the heating system will turn on at 19.5C 
and turn off at 20.5C.
This span value is adjustable. You can choose between 0.5, 1.0, 1.5 
and 2.0C.

To review or to change the temperature span

1. Press PROG key while the RETURN key is pressed.
2. Release both keys.
3. Press the up or down buttons to select the new temperature span.
4. Press the RETURN key or wait 10 seconds for the automatic return.

Note : Choosing a small temperature span such as 0.5C will be more 
comfortable (less temperature variation in the home) however the 
heating system will turn on and off more often.

Default Program

Program Number

Time 

Temp

Program Number

Time 

Temp

Monday to Friday 1
Monday to Friday 2
Monday to Friday 3
Monday to Friday 4
Saturday & Sunday 1
Saturday & Sunday 2

6:00 am
8:30 am
4:00 pm
11:00 pm
6:00 am
11:00 pm

21C
21C
21C
17C
21C
17C

Program Number

Time 

Temp

Program Number

Time 

Temp

Monday to Friday 1
Monday to Friday 2
Monday to Friday 3
Monday to Friday 4
Saturday & Sunday 1
Saturday & Sunday 2

Record your desired program here

Smart Temp Australia Pty Ltd 

 

19 Indra Road Blackburn South 3130

Phone:(03) 9899 6455 Fax (03) 9899 6454

www.thermostat.com.au

 Smart Temp

Thermostats

TM

Thermostat

Heater

R

W

Com

NO

NC

Typical Connections

!

Relay output, suitable for millivolt systems.

!

Contact rating up to 240VAC @ 8 Amps

!

7 Day vacation Timer.

!

Filter Monitor.

!

Adjustable Span (Dead Band) settings

!

Low battery indicator.

!

Powered by 2AA 

Alkaline

 batteries. (1 Year)

!