4.2.12 Security Engine (SEC) 3.1
The integrated security engine of the P2020 is designed to off load intensive security
functions like key generation and exchange, authentication and bulk encryption from the
processor core. It includes eight different execution units where data flows in and out of an
EU.
NOTE: The standard versions of the MVME2502 do not use the encryption enabled
versions of the P2020 processor.
10
A25
Not connected
09
A24
Not connected
08
F22
Not connected
07
R25
Not connected
06
R29
Connected to pin T6 of the CPLD (unused input)
05
R24
Connected to pin R6 of the CPLD (unused input)
04
U29
Connected to INTA of the QUART. Programmed as a discrete input or
to generate IRQ11.
Also connected to pin P16 of the CPLD. (unused input)
03
N24
Connected to pin P15of the CPLD
02
P29
Connected to Pin R16 of the CPLD. Programmed to generate a IRQ09
interrupt to the CPU based on contents of the CPLD GPIO2 interrupt
register. For more information see
PLD GPIO2 Interrupt Register on
01
R26
Connected to INTA_N of the DS1337 Real Time Clock (RTC).
Programmed as a discrete input or to generate IRQ08
00
R28
Connected to LED_P21[2] of the BCM5482S. Programmed as a
discrete input or to generate IRQ07.
Table 4-1
P2020 GPIO Functions (continued)
GPIO bit CPU Pin #
Function
Summary of Contents for MVME2502
Page 1: ...Penguin Edge MVME2502 Installation and Use P N 6806800R96L July 2022 ...
Page 8: ...8 MVME2502 Installation and Use 6806800R96L Table of Contents ...
Page 10: ...List of Figures 10 MVME2502 Installation and Use 6806800R96L ...
Page 18: ...18 MVME2502 Installation and Use 6806800R96L About this Manual About this Manual ...
Page 32: ...32 MVME2502 Installation and Use 6806800R96L Introduction Introduction ...
Page 96: ...96 MVME2502 Installation and Use 6806800R96L Functional Description Functional Description ...
Page 128: ...128 MVME2502 Installation and Use 6806800R96L Boot System Boot System ...
Page 140: ...140 MVME2502 Installation and Use 6806800R96L Programming Model Programming Model ...
Page 144: ...144 MVME2502 Installation and Use 6806800R96L Replacing the Battery Replacing the Battery ...
Page 148: ...148 MVME2502 Installation and Use 6806800R96L Related Documentation Related Documentation ...
Page 149: ...1 ...