14

 

Repeat these steps to add all other devices.

-  Show record

Move to “List Rec. [nn]”.

 

 

Where, “nn” is the number of record that stored within the system.

And select it with C-Key, it shows below.

 
 

Where : “*”, valid record, if no character at this position, it means no record at that position.

 

 

“nn”, record-number, its range is from “01” to “30”.

 

 

“RR”, room-number, its range is from “00” to “25”.

 

 

“B”, bed-number, its range is from “0” to “9”

 

 

“XXXX”, serial-number (ID) of the recorded TM-04.

Use A-Key to show next record.  When it show “:> <QUIT>”,  applying 

Caregiver key

 can then quit the  

list function. 

Or when it is showing a empty position (No record position), applying 

Caregiver key

, it shows,

 

Uses A-Key then to conirm to quit, or use 

Caregiver key

 again to cancel it.

 -  Delete record

There are two ways to delete records.

 

Delete a record:

 

To delete a record, go to the list rec. function irst, and then use 

Caregiver key

 when displaying a  

 

valid record, 

## Room Bed S/N

* nn RR B XXXX

<Quit>

Cordless PAD

:> Add Rec. [nn]

Summary of Contents for TL-2015R2

Page 1: ...nd Nurse Call Paging System InstallationandUseInstructions 433 PGD Caegiver Pocket Pager with LCD Display 433 NC Wireless Nurse Call Button Optional Accessories SMART CAREGIVER C O RPO RAT I O N Tel 8...

Page 2: ...2 Large Facility Central Monitor TL 2015R2 Connection Diagrams for Large Facility Central Monitor TL 2015R2...

Page 3: ...SETTING UP AND INSTALLING THE CARE STATION 3 0 OPTIONAL INTERFACE EXPANSION UNIT 4 0 APPROVALS 5 0 SUMMARY OF FEATURES AND FUNCTIONS 6 0 TECHNICAL SPECIFICATIONS 7 0 USER INSTRUCTIONS 8 0 LIST OF COMP...

Page 4: ...om ield equipment by providing different sound and display indications In addition a stand alone wireless transponder repeater unit WBUM 02 is available that can substantially increase the distance at...

Page 5: ...ot work properly The hand held tester unit may help locate the source in this case c Testing the wireless transmission on the site Up to 80 metre 250ft wireless range between devices is normal for Sma...

Page 6: ...op bit and no parity bit And the output looks like this Toilet Alert ID 010123 2011 01 26 16 27 06 2 1 6 Data In Out This is a spare port for future development 2 1 7 Relay O P May be used for Normall...

Page 7: ...res The length of such cable extension can be up to 250 metres Each ield receiver can detect data signals from an area having a radius up to 50 metres 150ft subject to survey and system range testing...

Page 8: ...terface interconnection cables If the interface unit CMJ 01 is to be employed and only it s incorporated ield data receiver is to be utilised a standard pre prepared cable connects between the Interfa...

Page 9: ...ifferent or its transmission may be interference by other transmitters This is also applied to the extension s receivers through CMJ 01 Please refer to the bottom of TL 2015R2 for the frequency conigu...

Page 10: ...ximum rating for relay output contacts 1 amp e g for door lock 6 Display Simultaneous alphanumeric text for several detected patient transmitter units These alerts rotate in the display window 7 User...

Page 11: ...central monitor OORC system auto checking function if enabled Used to detect if a ield unit becomes faulty or wireless interference is sensed This is reported and indicated at the TL 2015R2 7 3 1 Wire...

Page 12: ...cordless PAD you must irst is to register its ID in to TL 2015R2 So it needs the following functions to operate the registration Enter into setup mode You must use the caregiver key for this Press the...

Page 13: ...S N number ID of TM 04 and 00 is the irst number room assigned for this ID Use A Key to increate the room number its range is from 00 to 25 Once conirm the number use C Key to enter to next display Sa...

Page 14: ...its range is from 0 to 9 XXXX serial number ID of the recorded TM 04 Use A Key to show next record When it show QUIT applying Caregiver key can then quit the list function Or when it is showing a emp...

Page 15: ...n added to the working list memory The TL 2015R2 is now checking this pad continuously looking for the handshake signal every 30 seconds If it does not see this signal for 10 minutes it will show the...

Page 16: ...l Time Clock setup Real time clock setup function is under the SETUP menu use section 7 4 to go into setup mode And then select Clock Time 7 5 1 Change Date Use Caregiver key entering into the clock s...

Page 17: ...using for TL 2015R2 it shows 203 only that TL 2015R2 interprets the room number as 20 and the bed number is 3 So in order to make it display correctly in TL 2015R2 for BTX 02 programming that at the R...

Page 18: ...let button 007 Toilet button at position 007 LCD Display Toilet Alarm Area No 007 4 Wristband transmitter s Calls can be reset at the central monitor Note Due to the mobility of these units there is n...

Page 19: ...number LCD Display Door Fault 02 Other faults that are indicated a Power loss on units with batteries Bed mon AC loss 203 power is lost on this unit Only sent once since can be used battery only LCD...

Page 20: ...3004SYS TL 3005SYS Door monitor with LCD display and external strip receiver b TL 3004SYS TL 3005SYS Easy installed door strip monitor with no display display available on Central Monitor c TL 2012SR...

Page 21: ...21 Inter connections to TL 2015R2 TL 2015R2 TL 2015R2...

Page 22: ...22 TL 2015R2 TL 2015R2 Back View...

Page 23: ...23 TL 2015R2 TL 2015R2 Interface Unit...

Page 24: ...24 TL 2015R2 TL 3005 TL 2012SREV...

Page 25: ...25 TL 2015R2 TL 2015R2 Back View TL 3005 TL 2012SREV TL 3005...

Page 26: ...26 TL 2015R2 TL 3005 TL 2012SREV...

Page 27: ...27 TL 2015R2 1 TL 2015R2 2 TL 2015R2 3 Multi TL 2015R2 Application...

Page 28: ...28 TL 2015R2 TL 2015R2...

Page 29: ...29 TL 2015R2 3 Multi TL 2015R2 Application TL 2015R2 1 TL 2015R2 2...

Reviews: