Configuration
3.3
Idx
Parameter
Data
Type
Valid
Range
Initial/
Default Value
Units
Store
Description
22 SENSOR_CAL_LOC VisibleString
NULL
None
S
The location of last sensor calibration
This describes the physical location a
which the calibration was performed.
23
SENSOR_CAL_DATE
Time of Day
0
None
S
The date of the last sensor calibration
24 SENSOR_CAL_WHO VisibleString
NULL
None
S
The name of person who is in charge
of last calibration.
25
SECONDARY_VALUE
DS-65
INF
0
SUV
D
The secondary value related to the
temperature sensor.
26
SECONDARY_VALUE_UNIT
Unsigned16
See Table
1001 (
C)
E
S
The engineering units to be used
with the secondary value related to
the sensor.
27
DIGITAL_HALL
Float
0-65536
0
Na
D
Digital Hall Value.
28 DIAGNOSTIC_STATUS Unsigned16
Good
S
Show the device status (failures and
warnings)
29 READ_HALL_CAL_POINT_HI
Float
43786.0
S
Digital Hall value for the highest
calibration point.
30 READ_HALL_CAL_POINT_LOO
Float
24111.0
S
Digital Hall value for the lowest
calibration point.
31 SENSOR_TEMPERATURE
DS-65
0
C
D
The sensor temperature value
32 DIGITAL_TEMPERATURE
DS-65
INF
0
None
D
The digital temperature value.
33 CAL_TEMPERATURE
Float -40 a 85
C
25
C
S
The temperature value used to
calibrate the temperature.
34 ACTION_TYPE Unsigned8
Direct/Reverse
Direct
None
S
Defines if the action is direct or
indirect.
35 BACKUP_RESTORE Unsigned8
See
Table
0 Na
S
This parameter is used to backup or
to restore configuration data.
35 CAL_POINT_HI_BAKUP
Float
+INF
100
CU S
Indicates the backup for high
calibration point.
37 CAL_POINT_LO_BAKUP
Float
-INF
0
CU S
Indicates the backup for low
calibration point.
38 CAL_POINT_HI_FACTORY
Float
+INF
100
CU S
Indicates the high factory calibration
point.
39 CAL_POINT_LO_FACTORY
Float
-INF
0
CU S
Indicates the low factory calibration
point.
40 ORDERING_CODE VisibleString
Null Na
S
Indicates information about factory
production.
Table 3.1 – Parameters Table
Legend:
E - Enumerated parameter
Na - Adimensional parameter
RO - Read only
D - Dynamic
N - Non-volatile
S - Static
CU - CAL_UNIT
PVR - PRIMARY_VALUE_RANGE
Sec: Seconds
SR: SENSOR_RANGE
SVU: SECONDARY_VALUE_RANGE
Gray Background Line: Default Parameters of Syscon
Calibration
There is a specific method to make the calibration operation. It is necessary to match the source of
reference applied to or connected to the device with the wished value. At least four parameters
should be used to configure this process: CAL_POINT_HI, CAL_POINT_LO, CAL_MIN_SPAN, and
CAL_UNIT. Those parameters define the highest and lowest calibrated value for this device, the
minimum allowed span value for calibration (if necessary) and the engineering unit selected for
calibration purpose.
NOTE
TP302
has damping function implemented.
Summary of Contents for TP302
Page 15: ...Installation 1 9 Figure 1 9 Bus Topology Figure 1 10 Tree Topology ...
Page 34: ...TP302 Operation Maintenance and Instructions Manual 3 14 ...
Page 42: ...TP302 Operation Maintenance and Instructions Manual 4 8 ...
Page 51: ...Egtvkhkecvkqpu Kphqtocvkqp C09 Eqpvtqn Ftcykpi Canadian Standards Association CSA ...
Page 52: ...VR524 Qrgtcvkqp cpf Ockpvgpcpeg Kpuvtwevkqp Ocpwcn C0 ...