Infrared sensor:
Detecting human body’s infrared spectrum. Don’t
touch the surface by hand and keep it clean.
Tamper switch:
Once the case is opened in working state, the
tamper switch will be triggered and then generates an alarm signal.
LED Indication
The LED indicator can be turned on or off by setting jumpers. See
“PCB Layout” above.
Flash continuously:
Under self-testing state
Flash once:
Intruder is detected
Flash twice:
Test mode is finished, enters into the power-saving
mode.
Flash once every 3 seconds:
Undervoltage indication, please
change the batteries immediately.
Usage
Remove the insulating strip to activate batteries. It will enter into the
working state after one-minute’s self-testing.
Working Mode
Testing mode:
Press test button, the sensor enters into the testing
mode and detects once every 10 seconds. After 3 minutes, the LED
flashes twice, and the sensor enters into the power-saving mode.
Power-Saving Mode:
In working state, if the sensor is triggered twice
within 3 minutes, it will enter sleeping mode to save power. After
no movement within next 3 minutes, the sensor goes back to the
working state.
Installation & Notice
Wall-mounting:
Fix the bracket longitudinally on the wall, and put the detector on
the bracket. Choose to mount it at the entry and exit where the
intruder possibly breaks into. It is suggested to mount it at the
height of 2 m from the ground.
Ceiling-mounting:
Fix the bracket laterally on the ceiling upper the door or window,
and put the detector on the bracket.
Detecting distance:
Mount on wall
Mount at ceiling
Max. Height 3.6 m
Max. Length 5 m
Max. Width 1.3 m
Max. Height 3.6 m
Max. Length 5 m
Max. Width 1.3 m