Smach EFE 4000 Service Manual Download Page 14

14

 

 

Status

General troubleshooting

Checking point

Remedy

• Is  a na l og frequency i nput s i gna l  wi ri ng

correct?

• Is  vol ta ge of frequency i nput correct?

Is  opera ti on mode s etti ng correct?

• Opera te ope ra ti ons  through the di gi ta l

pa ne l .

Motor runs  

i nvers el y

Are wi ri ng for output termi na l s  T1, T2, a nd T3

corre ct?

• Wi ri ng mus t ma tch U, V, a nd W  termi na l s  of the  

motor.

Are wi ri ng for forwa rd a nd revers e s i gna l s

correct?

• Check wi ri ng a re correct i f neces s a ry.

Motor ca n      not 

run 

Is  power a ppl i ed to L1(L), L2, a nd L3(N)

termi na l s  (i s  the cha rgi ng i ndi ca tor l i t)?

• Is  the power a ppl i ed?

• Turn the power OFF a nd then ON

a ga i n.

• Ma ke  s ure the power vol ta ge i s  correct.

• Ma ke s ure s crews  a re  s ecured fi rml y.

Are there vol ta ge a cros s  the  output termi na l

T1, T2, a nd T3?

• Turn the power OFF a nd then ON a ga i n.

Is  ove rl oa d ca us i ng the motor bl ocke d?

• Reduce the l oa d to l et the motor

runni ng.

Are there a ny a bnorma l i ti es  i n the i nve rter?

• See  error des cri pti ons  to check wi ri ng

a nd corre ct i f ne ces s a ry.

Is  forwa rd or revers e runni ng comma nd i s s ued?

Motor s peed

va ri es

unus ua l l y

Is  the l oa d too hea vy?

• Reduce the l oa d.

Does  the  l oa d va ry l a rgel y?

• Mi ni mi ze the va ri a ti on of the l oa d.

• Increa s e ca pa ci ti es  of the i nve rter a nd

the motor.

Is  the i nput power l a ck of pha s e?

• Add a n AC rea ctor a t the  power i nput

s i de i f us i ng s i ngl e-pha s e powe r.

• Check wi ri ng i f us i ng three-pha s e

power.

Motor

runni ng

s pee d too

hi gh or too

l ow

Are s peci fi ca ti ons  of the motor (pol es ,

vol ta ge…) correct?

• Confi rm the motor’s  s peci fi ca ti ons .

Is  the ge a r ra ti o correct?

• Confi rm the gea r ra ti o.

Is  the s etti ng of the hi ghes t output frequency

correct?

• Confi rm the hi ghes t output fre quency.

The  motor

s pee d ca n

not be

regul a te d.

Are wi ri ng for a na l og frequency i nputs  correct?

• Check wi ri ng a re correct i f neces s a ry.

Is  the s etti ng of opera ti on mode correct?

• Che ck the ope ra ti on mode of the

opera tor.

Is  the l oa d too hea vy?

• Reduce the l oa d.

Ha s  a na l og frequency s i gna l  been i nput?

*General Troubleshooting of Inverter 

 

 

 

 

 

Summary of Contents for EFE 4000

Page 1: ...SOFT SERVE AND FROZEN YOGHURT FREEZER SERVICE MANUAL MODEL EFE 4000 Manual Number V 001 17 05 2012...

Page 2: ...pansion Valve Adjustment 2 Refrigeration System Schematic 3 Control Functions 4 Air Adjustment 5 Electrical System 6 Troubleshooting General Inverter 7 Inverter Control by a Laptop 8 Bacteria Troubles...

Page 3: ...ressure higher or lower by turning the expansion valve adjustment screw Clockwise turns will raise the pressure and counterclockwise will lower the pressure Bear in mind that In this model 360 turning...

Page 4: ...t cools down the mix in the cylinder around 6C when beater turns Machine checks the current in the beater motor by an inverter when the current is around 2 6Amp for soft mode 2 8 Amp for hard mode it...

Page 5: ...unt of aeration is desired The setting can be changed during operations by simply turning the INNER aeration tube to the desired size hole The SMALL HOLE will increase air percentage in the Soft Serve...

Page 6: ...6 5 ELECTRICAL SYSTEM...

Page 7: ...7...

Page 8: ...out dispensing ice cream Take out ice cream untill fresh mix is filled in cylinder Ice cream dispensed is too fast Do not exceed the production shown in the capacity 6 Mix or ice cream comes out from...

Page 9: ...vel 8V L level 2V PNP only LEVEL SENSOR Common contact for S1 S5 S6 S7 in PNP Source input Short circuit pin 2 and pin 3 refer to SYNPLUS wiring diagram of SW1 when used PNP input Rotary switch optica...

Page 10: ...celeration time setting too short or large load inertia 2 Power voltage varies widely 1 Set a longer deceleration time 2 Add a brake resistor or brake module 3 Add a reactor at the power input side 4...

Page 11: ...th the load 2 Increase inverter capacity 3 Improve ventilation conditions Inverter overload Heavy Load Increase the inverter capacity Over torque 1 Heavy Load 2 Insufficient settings of 9 14 9 15 1 In...

Page 12: ...a Stop command then a Run command to the inverter for it to be restarted 3 Stop key cannot perform emergency stop when 1 03 0001 External emergency stop The inverter will ramp stop and then flash E S...

Page 13: ...ent detection circuit is abnormal If Reset inverter is not available please send the inverter back for repair Parameter setting error 1 3 01in the range of 3 13 3 16 or 3 14 3 16or 3 15 3 16 2 3 00 3...

Page 14: ...y abnormalities in the inverter See error descriptions to check wiring and correct if necessary Is forward or reverse running command issued Motor speed varies unusually Is the load too heavy Reduce t...

Page 15: ...15 Quick Troubleshooting of Inverter...

Page 16: ...16 InverterFault...

Page 17: ...17...

Page 18: ...18 Inverterfault...

Page 19: ...7 INVERTER CONTROL BY A LAPTOP Inverter settings can be changed by the program named SYNPLUSand to connect to inverter over a laptop RS232 cable is needed Then follow the instructions to change settin...

Page 20: ...20...

Page 21: ...21...

Page 22: ...22...

Page 23: ...23...

Page 24: ...terms of human health Lack of them results in high bacteria counts when a sampling is taken by a sanitarian Bacteria counts should not exceed the following figures Therefore in a daily basis all machi...

Page 25: ...25...

Page 26: ...e temperature of the mix poured into the hopper is around room temperature It must take the temperature around 4C To control the hopper temperature panel and check the thermostat as seen in the photo...

Page 27: ...27 9 EXPLODED VIEWS...

Page 28: ...28...

Page 29: ...29...

Page 30: ...30...

Page 31: ...31...

Reviews: