5
Sunny Island
5.1
SI4.4M-12
Characterization of the PV storage system
PV2AC
PV2BAT
AC2BAT
BAT
BAT2AC
BAT2PV
Energy paths
✓
‒
✓
✓
✓
‒
AC Connection
Nominal charging power
3300 W
Nominal discharge power*
3300 W
* Rated output power BAT2AC
Battery Connection
Battery voltage*
41 V / 48 V / 63 V
Nominal charging power**
2500 W
Nominal discharge power
2500 W
* Nominal voltage or minimum/nominal/maximum voltage
** Rated output power AC2BAT
Battery
Mercedes-Benz Energy Storage Home 5.0
Battery voltage*
39.7 V / - / 54 V
Battery capacity**
3.75 kWh / 3.74 kWh / 3.69 kWh
Battery efficiency
94.3% / 95.5% / 95.2%
Power consumption of the battery management
system (no-load operation/standby)
6 W / 4 W
* Rated output power AC2BAT
** At 100% and, if applicable, 50% and 25% of the nominal charging/discharge power
Standby losses of the power conversion system
Power consumption during no-load operation
(AC/DC)
3 W / 16.1 W
Power consumption in standby (AC/DC)
0 W / 7.7 W
Control characteristics of the power conversion system
Average stationary deviation of the charging
power
-10 W
5 Sunny Island
SMA Solar Technology AG
Technical information
9
BattWr-Efficiency-TI-en-11
Summary of Contents for SUNNY BOY STORAGE