background image

SMA Solar Technology AG

Legal Restrictions

User Manual

SB33_38-BA-BEN114230

23

The information contained in this document is the property of SMA Solar Technology AG. Publishing its content, either partially or 

in full, requires the written permission of SMA Solar Technology AG. Any internal company copying of the document for the 

purposes of evaluating the product or its correct implementation is allowed and does not require permission.

Exclusion of liability

The general terms and conditions of delivery of SMA Solar Technology AG shall apply.
The content of these documents is continually checked and amended, where necessary. However, discrepancies cannot be 

excluded. No guarantee is made for the completeness of these documents. The latest version is available online at www.SMA.de 

or from the usual sales channels.
Guarantee or liability claims for damages of any kind are excluded if they are caused by one or more of the following: 
• Damages during transportation
• Improper or inappropriate use of the product
• Operating the product in an unintended environment
• Operating the product whilst ignoring relevant, statutory safety regulations in the deployment location
• Ignoring safety warnings and instructions contained in all documents relevant to the product
• Operating the product under incorrect safety or protection conditions
• Altering the product or supplied software without authority
• The product malfunctions due to operating attached or neighboring devices beyond statutory limit values
• In case of unforeseen calamity or force majeure
The use of supplied software produced by SMA Solar Technology AG is subject to the following conditions:
• SMA Solar Technology AG rejects any liability for direct or indirect damages arising from the use of software developed by 

SMA Solar Technology AG. This also applies to the provision or non-provision of support activities.

• Supplied software not developed by SMA Solar Technology AG is subject to the respective licensing and liability agreements 

of the manufacturer.

SMA Factory Warranty

The current guarantee conditions come enclosed with your device. These are also available online at www.SMA.de and can be 

downloaded or are available on paper from the usual sales channels if required.

Trademarks

All trademarks are recognized even if these are not marked separately. Missing designations do not mean that a product or brand 

is not a registered trademark.
The 

Bluetooth

®

 word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by 

SMA Solar Technology AG is under license.

SMA Solar Technology AG

Sonnenallee 1
34266 Niestetal
Germany
Tel. +49 561 9522-0
Fax +49 561 9522-100
www.SMA.de
E-Mail: [email protected]
© 2004 to 2011 SMA Solar Technology AG. All rights reserved

Summary of Contents for SUNNY BOY 3300

Page 1: ...SB33_38 BA BEN114230 TBEN SB33 38 11 Version 3 0 EN PV Inverter SUNNY BOY 3300 3800 User Manual...

Page 2: ......

Page 3: ...Safety Precautions 8 2 3 Explanation of Symbols 9 2 3 1 Symbols on the Inverter 9 2 3 2 Symbols on the Type Label 10 3 Product Overview 11 4 Display 12 4 1 Operation 12 4 2 Display Messages during Op...

Page 4: ......

Page 5: ...devices SB 3300 11 SB 3800 11 1 2 Target Group This manual is intended for the operator 1 3 Additional Information You will find additional information on the device specific technical data in the ins...

Page 6: ...ided will directly result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a hazardous...

Page 7: ...erating range of all components at all times The free design program Sunny Design www SMA de en SunnyDesign will assist you The manufacturer of the PV modules must have approved the PV modules for use...

Page 8: ...only be carried out by an electrically qualified person Electrical installation Repairs Modifications CAUTION Risk of burns through contact with the enclosure during operation Only touch the enclosure...

Page 9: ...tive Inform your installer An error has occurred Inform your installer immediately You can operate the display by tapping the enclosure lid Single tap The backlight switches on or the display scrolls...

Page 10: ...tion that accompanies the inverter The inverter must not be disposed of together with the household waste Further information on disposal can be found in the enclosed installation manual CE marking Th...

Page 11: ...Position Designation A Enclosure lid B Display C LEDs Green LED Operation Red LED Ground fault or varistor defective Yellow LED Fault D Fan guard E Type label for the identification of the inverter vi...

Page 12: ...during Operation After commissioning the inverter successively displays the device type the firmware version and the configured country setting If you want to view the display messages of the startup...

Page 13: ...e current values of the reactive power Qac and of the displacement power factor cos PF are displayed Total amount of energy fed in Total number of operating hours in feed in operation Display message...

Page 14: ...r feed in All LEDs are flashing The inverter is in the startup phase Green LED is on The inverter is feeding in to the power distribution grid Green LED is flashing This flashing can have the followin...

Page 15: ...lly monitored varistors on the DC input side is defective Inform your installer Yellow LED is on The inverter is in the operating state Permanent shutdown This can have several causes Inform your inst...

Page 16: ...our installer if you find any damage Do not perform any repair work yourself Maintenance and Cleaning Ask your installer to check for correct inverter operation at regular intervals If the inverter is...

Page 17: ...or safety reasons and ensures that the inverter does not connect to the power distribution grid Inform your installer Error An error has been detected Inform your installer Grid monitoring Grid monito...

Page 18: ...of the present disturbance error h on Total operating hours h total Total number of operating hours in feed in operation Iac Grid current Ipv Direct current Is Apparent current Power On Total number...

Page 19: ...ion unit The Electronic Solar Switch must be securely inserted into the bottom of the inverter and may only be removed by an electrically qualified person MPP Maximum Power Point Operating point of th...

Page 20: ...h the necessary assistance Inverter device type Inverter serial number Type and number of the PV modules connected Blink code or display message of the inverter Optional equipment e g communication pr...

Page 21: ......

Page 22: ......

Page 23: ...roduct under incorrect safety or protection conditions Altering the product or supplied software without authority The product malfunctions due to operating attached or neighboring devices beyond stat...

Page 24: ...USBMJB 1UZ UE XXX 4 VTUSBMJB DPN BV 4 FOFMVY 413 XXX 4 FOFMVY DPN 4 FJKJOH PNNFSDJBM P UE XXX 4 IJOB DPN 4 FDI 3FQVCMJD T S P XXX 4 FDI DPN 4 SBODF 4 4 XXX 4 SBODF DPN 4 FMMBT XXX 4 FMMBT DPN 4 C SJDB...

Reviews: