SMA Solar Technology AG
Parameter lists
Technical Description
SI5048-TEN093630
177
19.3.2 Battery Diagnosis (320#)
Number Name
Description
displayed
value
Description
Default
value
01
Soh
State of Health (SOH)
Ratio of current capacity to
its nominal value
100 %
02
StatTm
Statistics metering run time
in days
03
ChrgFact
Charging factor
1.00
04
BatEgyCntIn
Energy meter for battery
charge in kWh
05
BatEgyCntOut Energy meter for battery
discharge in kWh
06
AhCntIn
Meter for battery charging
ampere hours
07
AhCntOut
Meter for battery
discharging ampere hours
08
BatTmpPkMin Minimum battery
temperature in C°
09
BatTmpPkMax Maximal batter temperature
in C°
10
EquChrgCnt
Equalization charge meter
11
FulChrgCnt
Full charge meter
12
BatCurOfsErr
Offset error of battery
current in A
13
OcvPointCnt
Meter for open-circuit
voltage points
15
AhCntFul
Meter for battery
discharging ampere hours
since the last full charge
(in Ah/100 Ah)
16
AhCntEqu
Meter for battery
discharging ampere hours
since the last equalization
charge (in Ah/100 Ah)
17
BatVtgPk
Maximal battery voltage to
have ppeared in V
18
BatCurPkIn
Maximal battery current in
the charging direction to
have appeared (in A)
Summary of Contents for SI 5048
Page 2: ......
Page 10: ...Table of Contents SMA Solar Technology AG 10 SI5048 TEN093630 Technical Description...
Page 43: ...SMA Solar Technology AG Electrical Connection Technical Description SI5048 TEN093630 43...
Page 209: ......
Page 210: ......
Page 212: ...4 4PMBS 5FDIOPMPHZ XXX 4 EF...