14 Procedure for Receiving a Replacement Device
SMA Solar Technology AG
Operating manual
SHP-US-20-BE-en-10
86
14 Procedure for Receiving a Replacement Device
Under fault conditions, the product may need to be replaced. If this is the case, you will receive a
replacement device from SMA Solar Technology AG. If you received a replacement device,
replace the defective product with the replacement device as described below.
1. To simplify the configuration of the replacement device, save the configuration data of the
defective product to a file (see Section 9.10, page 55).
2. Decommission the defective product (see Section 13, page 82).
3. Remove the transport cover, which is located in the
housing opening of the replacement unit instead of
the connecting plate, and use it for the defective
product.
4. Secure the pre-configured DC connection cables in
the defective product for transport. To do so, screw
the supplied cable tie into the hole below the DC
surge protection devices and place and tighten the
cable tie around the DC connection cables.
1
2
5. Mount the replacement device and make the electrical connections as described in this
document. Use the connection plate and the DC protection elements against contact of the
defective product.
6. If the enclosure lid of the replacement device is a transport lid (see information on the
enclosure lid), replace the transport lid of the replacement device with the enclosure lid of the
defective inverter: