10 Technical Data
SMA Solar Technology AG
Installation Manual
SBxx-1SP-US-40-IA-xx-15
68
SB6.0-1SP-US-40
SB7.0-1SP-US-40
SB7.7-1SP-US-40
Maximum apparent
AC power at 208 V
5200 VA
6650 VA
6650 VA
Maximum apparent
AC power at 240 V
6000 VA
7000 VA
7680 VA
Rated grid voltage
208 V / 240 V
208 V / 240 V
208 V / 240 V
AC voltage range at
208 V
183 V to 229 V
183 V to 229 V
183 V to 229 V
AC voltage range at
240 V
211 V to 264 V
211 V to 264 V
211 V to 264 V
Nominal AC current at
208 V
25 A
32 A
32 A
Nominal AC current at
240 V
25 A
29.2 A
32 A
Maximum output cur-
rent at 208 V
25 A
32 A
32 A
Maximum output cur-
rent at 240 V
25 A
29.2 A
32 A
Total harmonic factor
of output current
<4 %
<4 %
<4 %
Maximum residual out-
put current
30.4 A
30.4 A
30.4 A
Duration of the maxi-
mum residual output
current
250 ms
250 ms
250 ms
Line synchronization
characteristics/inrush
current
Method 2/2.4 A
Method 2/2.4 A
Method 2/2.4 A
Rated power frequency
60 Hz
60 Hz
60 Hz
Operating range at AC
power frequency
60 Hz
59.3 Hz to 60.5 Hz
59.3 Hz to 60.5 Hz
59.3 Hz to 60.5 Hz
Output power at
+60°C (+140°F)
> 3300 W
> 6700 W
> 6700 W
Power factor at rated
power
1
1
1