5 Assembly
5.1.2 Mounting the Combiner Box
Danger of crushing if the Combiner Box is dropped
•
When mounting the Combiner Box, take the weight of up to 35 kg into account.
•
Two people are needed to mount the Combiner Box.
•
Installer should use personal protective equipment.
Damage to cable glands and plug connections due to improper transport and installation
The cable glands and plug connections protrude from the enclosure.
•
When transporting and mounting the Combiner Box, ensure that the cable glands and plug connections are not
damaged.
Additionally required mounting material (not included in the scope of delivery):
•
Four M8 screws. Take wall properties into account when choosing the screw type.
•
Four washers
•
If necessary, four screw anchors. Take wall properties into account when choosing the screw anchor type.
650
700
270
Figure 6a: Dimensions of the Combiner Box 16/24