SM ProAudio OC8E Operating Manual Download Page 7

7

Installation - Front Panel Controls

Analog outputs

8 x ¼” TS analog output connectors are provided for each of the eight (8) compressor channels.
Individual output levels can be controlled via the associated channels rotary output gain control
encoder on the front panel.

4. FRONT PANEL CONTROLS & INDICATORS

4.1 Independent (8x) comp on/off bypass switches

The COMP switch toggles the channel bypass functions for each compressor module on or off.

* This is very handy for comparing compressed audio with your original non-compressed audio pro-
gram material.

4.2 Independent (8x) peak led indicators

Each channel features a peak light LED indicator. This momentarily indicates when the input sig-
nal strength has reached optimum input level.

* A continuously illuminated peak LED indicates you have surpassed optimum input level and dis-
tortion of the respective channels audio signal will occur. It’s time to adjust your input gain structure!

4.3 Independent (8x) rotary compression threshold encoders & tri-state led indicator

Each compressor modules COMPRESS encoder acts as a threshold adjustment. When input level
is below the threshold the signal is unaffected. When input level exceeds the threshold attenuation
of the output signal occurs.

A tri-state LED is available which indicates the following:

Green – Compressor module active,
Yellow/Orange – mild compression, input signal has exceeded the threshold level
Red – heavy compression, signal level has exceeded the threshold setting considerably

4.4 Independent (8x) rotary attack encoders

The rotary attack controls allow for adjustment in milliseconds the time it takes each compressor
module to respond to the corresponding input signals before gain reduction occurs. Short attack
times quickly bring down the level of the loud, fast transients in the audio signal; long attack times
let more sound through before the compressor engages, resulting in a punchier sound.

4.5 Independent (8x) rotary release encoders

The release controls set the time in seconds it takes for each compressor modules gain to return to the
point of no gain reduction in the absence of audio program material. Short release times create a more
exaggerated effect ("breathing"), whereas long release times have a more gradual, natural sound.

4.6 Independent (8x) rotary output encoders

The rotary output controls set the output level of each compressor module. Often after reducing the sig-
nals dynamic range with processing such as compression, you require a process to ‘make-up’ the lost

OC8E front panel

Summary of Contents for OC8E

Page 1: ......

Page 2: ...nding and Polarization Never defeat the products power grounding means Power Cord Protection Power supply cords should be connected or placed in a fashion that could allow possible exposure to damage Take care to avoid wear and tear rubbing squashing etc Cleaning The product should be cleaned only with a soft cloth Do not use any corrosive products on the unit Inactivity The power cord of the prod...

Page 3: ...C8E Main Features The OC8E is a professional multi channel optical compressor featuring 8 x fast electro optical compressor modules 8 x VU Meters output meter Adjustable attack release and compression threshold Low noise wide bandwidth and superior transient response Class A transformerless high voltage signal path Bypass on switch per channel Peak LED indicator per channel input peak 1 4 line lev...

Page 4: ...endent 8x comp on off bypass switches 7 4 2 Independent 8x peak led indicators 7 4 3 Independent 8x rotary compression threshold encoders led indicator 7 4 4 Independent 8x rotary attack encoders 7 4 5 Independent 8x rotary release encoders 7 4 6 Independent 8x rotary output encoders 7 4 7 Independent 8x VU Meters 8 5 APPLICATION 8 5 1 General use of the OC8E 8 5 2 PR8IIA Optional ADAT output modu...

Page 5: ...ard is perfect for users wanting to interface or add eight 8 additional channels of quality pre amplification to a vari ety of digital devices such as digital mixers audio recording interfaces etc 2 THE DESIGN 2 1 High quality components and design The philosophy behind SM Pro Audio products guarantees a no compromise circuit design and fault tolerant component selection All SM Pro Audio products ...

Page 6: ... To connect the OC8E to your mains power source simply connect the included standard IEC mains power cable to the OC8E s three 3 pin power connector socket Power on off switch LED power indicator The OC8E s power switch can be found on the right hand side of the front panel To enable power to the OC8E or turn on simply place the power on off switch into the down position The LED power indicator wi...

Page 7: ...en input level exceeds the threshold attenuation of the output signal occurs A tri state LED is available which indicates the following Green Compressor module active Yellow Orange mild compression input signal has exceeded the threshold level Red heavy compression signal level has exceeded the threshold setting considerably 4 4 Independent 8x rotary attack encoders The rotary attack controls allo...

Page 8: ...n your signal path Set your input gain control The incoming signal strength cannot be adjusted on the OC8E It must me set prior to arriving at the units inputs View the LED meter to analyze the incoming signal strength in dB This allows you a good visual indicator so you can adjust your signal from the source ie mixer gain preamplifier gain control Apply the desired compression settings for each c...

Page 9: ...lock I O connections and a sample rate selector switch 44 1 48kHz Note Both analog outputs from the OC8E and the PR8IIA s ADAT digital output function simul taneously 6 SPECIFICATIONS LINE INPUTS Connector TS jack Type unbalanced LINE OUTPUTS Connector TS jack Type unbalanced FREQUENCY RESPONSE Line in 6Hz to 20Hz within 1dB COMPRESSOR Photoresistive servo operated Ratio minimum 1 5 to 1 Ratio max...

Page 10: ...nty period This warranty does not apply if the product has been damaged by negligence non authorized mod ifications accident abuse misuse misapplication or as a result of unauthorized service other than performed by that of SM Pro Audio s service department All freight charges incurred for transport of justified warranty claims are at the buyer s expense All other warranty claims other than those ...

Page 11: ... This warranty does not cover defects of parts caused by normal operational wear These parts are typically switches knobs and other similar components Product damage caused by the following conditions are not covered by this warranty Operation of the unit in a way that does not comply with the safety regulations applicable in the country where the product is used Damages or defects caused by condi...

Page 12: ...hange without notice ALL RIGHTS RESERVED 2007 SM Pro Audio SM Pro Audio Service Department Warehouse 25 Roberna Business Park 26 28 Roberna St Moorabbin 3189 Melbourne Victoria Australia PH 61 3 9555 8081 FAX 61 3 9555 8083 www smproaudio com 12 Legal Notice ...

Reviews: