1. Use as directed:
This product serves exclusively lighting purposes and may:
only be used with a voltage of
230V ~50Hz
.
only be used in dry condition,
not in damp or dirt-endangered rooms.
not in areas of high air humidity.
not be exposed to strong mechanical loads or to strong
contamination.
only be installed and operated after a condition inspection if the
product is dirty or has been moistened through storage.
not be modified or converted.
If these points named above are not adhered to, a short circuit or
electrical shock may occur!
2. Technical Data:
154602
154612
Operating voltage:
230V ~50Hz
Safety class:
I
1x 2x
Bulb:
QPAR111, GU10, max. 75W
Dimensions (L/W/H):
20,5/20,5/15 cm
39/21/15 cm
Recess dim. (L/W/H):
17/17/15 cm
35,5/18/15 cm
Rotary-/ Swivel range:
cardanic
Weight:
1,25 kg
2,25 kg
Importer: SLV
Elektronik
GmbH
3. Installation
The electric connection may be executed only by an electric
expert who is familiar with the valid directives!
Attention: Switch off the power of the mains supply line or
respectively of the connection lead before doing any works!
Use only parts, which belong to the product! Otherwise the product or the
installation might not be sufficiently safe.
Installation place:
The product is intended for installation in
suspended ceilings
.
Make sure that the product is mounted on a
stable, even and tilt-fixed
background
. Note the minimum distances in the ceiling. Minimum distance
to each side: 5 cm.
Do not cover the product
, especially not with
insulating materials. The
light exit
should be placed at least so far from the
illuminated surface, as indicated as
minimum distance
on the type plate of
the luminaire:
.
Pay special caution
to easily inflammable
objects (e.g. curtains).
Separate Installation Steps
Mark and cut the opening (see Technical Data). Do not damage the
mains lead.
Remove the cover on top of the connection clamp.
Loosen the strain relief. Direct the mains lead through the strain relief.
Electrical
Connection
The product must be able to be separated by an all pole separation
from the current supply.
For electric connection attach the black or brown wire (live conductor)
of the mains lead with the
clamp L
and the blue wire (neutral
conductor) of the mains lead with the
clamp N
. The green-yellow wire
(protective conductor) of the mains lead has to be tightly screwed into
the
earth clamp
of the product.
Put the cover back on the clamp.
Secure the mains lead with the strain relief.
I: Direct the downlight into the opening, with the retaining springs
pointing upwards.
II: Insert the mounting clips into the guidings and pull them down.
Pay attention that the product cannot fall down after installation!
Inserting the bulb: Insert the bulb with a quarter-turn to the right.
The product is now ready for operation.
4. Operation
:
Information for the user:
Operate the product only if it is working correctly. Switch off the product
with a malfunction immediately and operate it again only after examination
by an electrical specialist. This is the case, when:
visible damages appear.
the product does not work.
smoke, steam or crackling sounds appear.
an overheating is recognisable.
Repairs of the product or work on mains voltage-prominent sections may
only be carried out by qualified electricians.
Attention:
Here exists mortal danger from an electric shock!
How to avoid failure and fire risk:
Do not cover the product - provide free air circulation!
Do not hang or fasten anything on the product, especially no decoration.
Never let children play unsupervised with electric products! Children
can not always estimate dangers in dealing with electric energy correctly.
What is to do if a bulb is defect or does not work?
Disconnect the product from power
, before you exchange the bulbs.
Caution:
Let the
bulb cool down
first before replacement –
otherwise considerable risk of injury exists because of the hot surface.
Replace the bulbs only with bulbs of the same data like socket, power
and capacity. Every other sort of bulb can lead to damages of the light.
Replacing the bulb
: see Installation.
5. What else has to be considered?
Disconnect the product from power
, before you…
clean or maintain the product.
do any works on the product or its components (electric expert).
Art.-Nr. 154602/12 12/2007
©
by SLV Elektronik GmbH
Technical Details are subject to change.
Duplication prohibited !
ENGLISH
Instruction Manual
for recessed fitting
AIXLIGHT
®
MOD FLAT I/II ES111
Please read carefully and keep for further reference !
10-24mm
5-24mm