background image

 
 
 
 
 
 
 
 
 
 
1.    Use as directed: 

This product serves exclusively lighting purposes and may: 

ƒ

  only be used with a voltage of 

230V ~50Hz

ƒ

  only be used in dry condition, 

ƒ

  not in damp or dirt-endangered rooms. 

ƒ

  not in areas of high air humidity. 

ƒ

  not be exposed to strong mechanical loads or to strong 

contamination. 

ƒ

  only be installed and operated after a condition inspection if the 

product is dirty or has been moistened through storage. 

ƒ

  not be modified or converted. 

 If these points named above are not adhered to, a short circuit or 

electrical shock may occur! 
 

2.    Technical Data: 

 

 154602 

154612 

Operating voltage: 

230V ~50Hz 

Safety class: 

1x 2x 

Bulb:  

QPAR111, GU10, max. 75W 

Dimensions (L/W/H): 

20,5/20,5/15 cm 

39/21/15 cm 

Recess dim. (L/W/H): 

17/17/15 cm 

35,5/18/15 cm 

Rotary-/ Swivel range: 

cardanic 

Weight: 

1,25 kg 

2,25 kg 

Importer: SLV 

Elektronik 

GmbH 

 

3.    Installation 

 

The electric connection may be executed only by an electric 

expert who is familiar with the valid directives!

 

 Attention: Switch off the power of the mains supply line or 

respectively of the connection lead before doing any works!  

Use only parts, which belong to the product! Otherwise the product or the 
installation might not be sufficiently safe.  

 
Installation place: 

The product is intended for installation in 

suspended ceilings

Make sure that the product is mounted on a 

stable, even and tilt-fixed 

background

. Note the minimum distances in the ceiling. Minimum distance 

to each side: 5 cm. 

Do not cover the product

, especially not with 

insulating materials. The 

light exit

 should be placed at least so far from the 

illuminated surface, as indicated as 

minimum distance

 on the type plate of 

the luminaire: 

Pay special caution

 to easily inflammable 

objects (e.g. curtains). 

 
Separate Installation Steps 

ƒ

  Mark and cut the opening (see Technical Data). Do not damage the 

mains lead. 

ƒ

  Remove  the cover on top of the connection clamp. 

ƒ

  Loosen the strain relief. Direct the mains lead through the strain relief. 

ƒ

 Electrical 

Connection 

ƒ

  The product must be able to be separated by an all pole separation 

from the current supply. 

ƒ

  For electric connection attach the black or brown wire (live conductor) 

of the mains lead with the 

clamp L

 and the blue wire (neutral 

conductor) of the mains lead with the 

clamp N

. The green-yellow wire 

(protective conductor) of the mains lead has to be tightly screwed into 

the 

earth clamp

 

 of the product. 

ƒ

  Put the cover back on the clamp. 

ƒ

 

Secure the mains lead with the strain relief. 

ƒ

  I: Direct the downlight into the opening, with the retaining springs 

pointing upwards. 

ƒ

  II: Insert the mounting clips into the guidings and pull them down. 

ƒ

  Pay attention that the product cannot fall down after installation! 

ƒ

  Inserting the bulb: Insert the bulb with a quarter-turn to the right. 

ƒ

 

The product is now ready for operation.

 

 

4. Operation

Information for the user: 

Operate the product only if it is working correctly. Switch off the product 
with a malfunction immediately and operate it again only after examination 
by an electrical specialist. This is the case, when: 

ƒ

  visible damages appear. 

ƒ

  the product does not work. 

ƒ

  smoke, steam or crackling sounds appear. 

ƒ

  an overheating is recognisable. 

Repairs of  the product or work on mains voltage-prominent sections may 
only be carried out by qualified electricians. 

 

Attention:

 Here exists mortal danger from an electric shock! 

 

How to avoid failure and fire risk: 

ƒ

  Do not cover the product - provide free air circulation! 

ƒ

  Do not hang or fasten anything on the product, especially no decoration. 

 Never let children play unsupervised with electric products! Children 

can not always estimate dangers in dealing with electric energy correctly. 

 

What is to do if a bulb is defect or does not work? 

ƒ

 

Disconnect the product from power

, before you exchange the bulbs. 

ƒ

 

 

Caution:

 Let the 

bulb cool down

 first before replacement – 

otherwise considerable risk of injury exists because of the hot surface. 

ƒ

  Replace the bulbs only with bulbs of the same data like socket, power 

and capacity. Every other sort of bulb can lead to damages of the light. 

ƒ

 

Replacing the bulb

: see Installation. 

 

 5.    What else has to be considered? 

Disconnect the product from power

, before you… 

ƒ

  clean or maintain the product. 

ƒ

  do any works on the product or its components (electric expert). 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Art.-Nr. 154602/12        12/2007   

©

 by SLV Elektronik GmbH  

Technical Details are subject to change.  

Duplication prohibited ! 

ENGLISH  

Instruction Manual 
for recessed fitting 

AIXLIGHT

® 

MOD FLAT I/II ES111 

Please read carefully and keep for further reference ! 

 

10-24mm

5-24mm

 

Reviews: