8
SLS™ CS6600 Line Array Module and CS6600RF Rigging Frame User’s Guide
Installing the SLS CS6600
2.2.4
Attaching CS6600RF Safety Cable to Building Structure
After
the
frame
is
rigged
to
the
building
structure,
you
must
rig
a
secondary
safety
attachment
point
to
an
independent
point
on
the
building
structure.
You
must
use
only
rigging
points
on
the
center
spar
of
the
CS6600RF
for
attaching
this
safety
rigging
hardware.
All
installer
‐
supplied
rigging
hardware
must
have
a
minimum
5:1
safety
factor,
or
greater
if
a
higher
requirement
is
mandated
per
local
laws.
Figure
2
‐
4
Figure 2-4
Example of Safety Cable Attached from CS6600RF to Building Structure
2.2.5
Attaching CS6600 to CS6600RF
You
attach
the
first
CS6600
line
array
module
in
the
array
to
the
rigging
frame
using
the
three
provided
positive
lock
pins
that
are
provided
with
the
CS6600.
The
correct
points
for
attachment
are
shown
in
the
following
figure.
To
insert
the
pin:
1.
Push
the
positive
‐
lock
release
button,
which
is
located
at
the
center
of
the
pin
back
head.
2.
Insert
the
pin
into
the
hardware
and
release
the
button.
Warning:
INSTALLER
‐
SUPPLIED
RIGGING
HARDWARE
MUST
HAVE
A
MINIMUM
SAFETY
FACTOR
BASED
ON
THE
WEIGHT
OF
THE
APPARATUS,
INCLUDING
THE
CABLE
AND
ANY
ATTACHMENT
HARDWARE.
YOU
MUST
SECURELY
TIGHTEN
THE
HARDWARE
AND
PREVENT
ACCIDENTAL
UNSCREWING
OR
UNCOUPLING
OF
THE
HARDWARE.
REMOVE
ALL
SLACK
FROM
THE
CABLE
TO
PREVENT
ANY
SHOCK
LOADING
THAT
COULD
CAUSE
THE
CABLE
TO
FAIL.
REPLACE
SAFETY
CABLE
AND
HARDWARE
IF
IT
HAS
BEEN
STRESSED
BY
A
PRIMARY
RIGGING
FAILURE.
USE
ONLY
THE
CENTER
SPAR
IN
THE
FRAME
FOR
THE
LOCATION
OF
THE
SAFETY
ATTACHMENT.
Safety cable
Primary rigging cable