PAGE 2 OF 3
Symphony
Bollard
10Y
P+
EM
DIM
Sensors
Sensitivity
Hold time
Threshold
Standby
dim level
Standby time
20%
10 seconds
Disabled
0%
1 minute
50%
1 minute
10 Lux
10%
5 minutes
75%
5 minutes
30 Lux
30%
15 minutes
100%
15 minutes
50 Lux
50%
60 minutes
30 minutes
∞
Photocontrol available (installed in column).
Sensor Type & Detection
Mounting
¶
0.375”
(10 mm)
11”
(279 mm)
2”
(51 mm)
ROD
DIA
Versatile
mounting
holes
Phillips head
screws (3)
Phillips head
screws (3)
0.375”
(10 mm)
11”
(279 mm)
2”
(51 mm)
ROD
DIA
Includes three (3)
0.375" (10 mm) x 11"
(279 mm) x 2" (51 mm)
anchor bolt, hex nut,
and washers
¥ Emergency lumens for 30 W = 240 L,
40 W = 320 L, 50 W = 400 L, 72 W = 576 L
Emergency Battery Backup
•
90-minute run time
•
CSA C22.2 No. 141, UL924
•
Internal battery with test button
•
8 W
¥
•
Ambient operating temperature:
32° F to 104° F (0° C to 40° C)
•
Title 20 Certified
Optional 8 W EM battery backup
with metal test button
Dimensions
Dimensions & Weight
Model
Dimensions
(Dia.
x
H)
Weight
BD6
5.74" (146 mm) Dia.
x 42" (1067 mm)
15.2 lbs.
(6.9 kgs)
BT6
13" (330 mm) Dia.
x 41.8" (1062 mm)
18 lbs.
(8.2 kgs)
SYM-BD Post Top
41
.8
" (
10
62 m
m
)
13"
(330 mm)
SYM-BD Dome Top
5.74"
(145.8 mm)
42
" (
10
67 m
m
)