background image

CARRIER STUD PLACEMENT 

I if using 

in-wall carrier, set bearing rods as 

shown above.

SET DRAIN LINE HEIGHT 

 17” from  

finished floor (standard 24” rim) or 10” for 

ADA installation. Threaded nipple should 

extend ½ to ¾” from wall.

A. Clean face 

of existing drain nipple. 

B. Install the clear inspection disc

 with 

compression nut. 

C. Slowly pour water

 into the drain.

D. Use a flashlight to check the pitch/

slope

. No water should be present in 

the inspection disc or nipple. 

E. Remove disc

 and nut after inspection.

"

DRILL HOLES 

 masonry 

bit for the lower anchor screws 

and mounting plate and insert 

plastic anchors where indicated.

TIGHTEN COMPRESSION 

NUT AND HOSE CLAMP.

DETERMINE THE DRAIN NIPPLE DEPTH

 

by measuring the distance between the 

back of the sanitary tee (or elbow) to 

the front edge of the nipple.

MEASURE & MARK THE ROUGH-IN 

if

masonry bit to drill hole, then install 

the hanger bracket with one plastic 

anchor and screw.

"

ADJUST DRAIN TO ACHIEVE PITCH 

only if standing water is present 

(code requires ¼” drop per foot of 

drain line for proper pitch). Seal wall 

according to code.

A.

 

Hang the bowl on the bracket 

and check tail 

pipe alignment, then remove the bowl and 

adjust the bracket as needed. 

 

Re-hang and re-check bowl  

alignment with 

the drain line.  Tail pipe should align with center 

of drain line. 

B.

 

Mark anchor holes 

then 

remove bowl without 

moving hanger bracket.

INCORRECT

Not centered

CORRECT

Centered

A

B

½"  

to

 ¾"

10" 

for ADA 

installation

standard 24" rim

finished floor 

17"

1 ⁄

1 "

13 ⁄ "

Drain

Cut away wall

Lift drain line & brace 

with mending plate

Install two 

additional screws

A.

 

Find the drain nipple depth

 on 

the Tube Cutting Chart (left).

 

Measure and mark the specified 

trim length 

on the insert tube at 

the nearest ¼” groove.

B.

 

Cut the tube

 at the groove using a sharp 

utility knife to ensure a square, flat cut. 

C.

 

Clean burrs 

from the cut end by using 

emery paper.

D.

 

Apply lubricant

 to the outside of the 

rubber bushing and ribbed inside area. 

E.

 

Insert the tube 

and bushing with arrow 

tab at the top. Apply lubricant to tailpipe 

of housing. 

IMPORTANT:

 Be sure arrow tab 

is at 12:00 position.

1

2

3

4

Arrow 
tab UP

1

2

3

4

A

C

B

D

E

POUR 5 

GALLONS 

OF WATER

 

as rapidly 

as possible 

into housing 

to ensure 

good flow 

and no leaks or 

standing water.

CAULK THE BOWL 

TO THE WALL 

if 

there is good flow 

and no leaks or 

standing water.

INSTALL 

CARTRIDGE

 

per the cartridge 

instruction sheet.

CARTRIDGE 

INSTRUCTIONS

HANG THE BOWL,

 inserting tailpipe 

into bushing, then install anchor 

screws with washers.

 PLACE THE HOSE CLAMP 

and compression nut onto the 

housing tailpipe.

13 ⁄ "

 

Install plastic anchor 

and screw here

14

15

4

13

3

12

8

6

2

10

11

7

5

1

C

D

9

WES-7000 WATERFREE URINAL

NEW CONSTRUCTION

INSTALLATION INSTRUCTIONS

BEFORE STARTING INSTALLATION:

  

 

IMPORTANT 

 Do not install on copper DWV

   due to copper’s susceptibility to corrosion.

     Check rough-in height to achieve 24” rim height

     (17” rim height for ADA).

     Check slope.  Downhill slope, per code, is essential 

     because waterfree urinals depend on gravity flow.

     Check DWV material.  Suitable materials include 

     cast iron, PVC, ABS and galvanized steel.

TUBE CUTTING CHART

     Measure drain nipple depth (inches) to find trim

     length (inches)

     13 7/8” or more DO NOT CUT

     3 3/4” or less DO NOT USE TUBE

• 

• 

• 

• 

OR LESS

TRIM

13 ¾"

¼"

13 ½

½

13 ¼

¾

13

1

12 ¾

12 ½

12 ¼

12

2

11 ¾

11 ½

11 ¼

11

3

10 ¾

3 ¼

10 ½

3 ½

OR LESS

TRIM

10 ¼"

3 ¾"

10

4

9 ¾

4 ¼

9 ½

4 ½

9 ¼

4 ¾

9

5

8 ¾

5 ¼

8 ½

5 ½

8 ¼

5 ¾

8

6

7 ¾

6 ¼

7 ½

6 ½

7 ¼

6 ¾

7

7

OR LESS

TRIM   

6 ¾"

7 ¼"

6 ½

7 ½

6 ¼

7 ¾

6

8

5 ¾

8 ¼

5 ½

8 ½

5 ¼

8 ¾

5

9

4 ¾

9 ¼

4 ½

9 ½

4 ¼

9 ¾

4

10

CUSTOMER SERVICE

1-888-SLOAN-14 (1-888-756-2814)

[email protected]

www.sloanvalve.com

The information in this document is subject to change without notice.

© 2015 Sloan Valve Company All rights reserved.                

  (08-15)Rev1

CAUTION

 After removing any urinal from the 

drain line, it’s normal for certain naturally occurring, 

but potentially hazardous sewer gases  to escape 

through the opening until the waterless cartridge 

is installed properly into the waterless urinal. If you 

need to leave an open drain line unattended after 

removing the urinal from the wall, temporarily wedge paper towels or a 

rag into the drain hole to reduce any outflow of sewer gases, and remove 

the paper towels or rag prior to completing the urinal or cartridge 

installation. 

Never smoke, have an open flame, or place your nose or 

mouth near open drain lines or waterless urinal housings into which 

a cartridge is not yet properly installed.

 You also can wear a breathing 

mask when removing or installing any waterless urinal or cartridge to 

reduce potential exposure to any such gases.

LUBRICANT

in-wall carrier is not used. Use a  

11

10

12

Reviews: