background image

Finished Wall

4.

 

Use the Water Level to make sure the Valve is level. F

inish the wall. Use

       

 marks on mudguard to make sure finished wall is in

 between 2” (51 mm) 

        and 3” (76 mm) from centerline of the inlet pipe.

5.

Only Remove the mudguard when installing Wall Plate

.

 For more information

Refer Wall Plate Installation Manual (08160044).

Note: Removing the Mudguard beforehand might result in 

damge to the solenoid 

      from debris.

2. CONNECT FLUSHOMETER (HARDWIRE CONNECTION)

TRANSFORMER  NOT  PROVIDED.  IT  IS  VERY  IMPORTANT  THAT  THE 

OUTPUT VOLTAGE OF THE TRANSFORMER MUST BE 6VAC FOR THE UNIT 

TO  FUNCTION  PROPERLY.  SLOAN  EL-386  OR  EL-451  IS  RECOMMENDED 

(120 VAC/6VAC) OR ELG-220 (220VAC/6VAC). 

1.

Remove

 one of the knockout caps and route the transformer wire trough it inside

wall box.
NOTE: Use a conduit pipe to protect the transformer wire from damage during

 installation.

2

.

Finish the wall

 as instructed above.

!!! IMPORTANT !!!

3

Summary of Contents for TRUFLUSH TRF 8036

Page 1: ...e there is easily accessed plumbing for the fixture and the valve This valve is designed for minimum six inch 152 mm wall space depth Distance from center of the valve inlet or outlet pipe to the finished surface of the wall can vary from 2 3 51 76 mm Wall plate opening must be of 5 6 x 5 6 142 x 142 mm Mud plate is provided and must accompany valve for proper installation Mud plate is removed aft...

Page 2: ...E VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED CONSULT FIXTURE MANUFACTURER FOR MINIMUM PRESSURE REQUIREMENTS MOST HIGH EFFICIENCY WATER CLOSETS REQUIRE A MINIMUM FLOWING PRESSURE OF 25 PSI 172 KPA MANY BUILDING CODES AND THE ASME A112 19 2 FIXTURE STANDARD LIST MAXIMUM STATIC WATER PRESSURE AS 80 PSI 552 KPA CLOSET 40 1016 mm 2 Connect the inlet pipe to top IN and fixture flush connection ...

Page 3: ...uard beforehand might result in damge to the solenoid from debris 2 CONNECT FLUSHOMETER HARDWIRE CONNECTION TRANSFORMER NOT PROVIDED IT IS VERY IMPORTANT THAT THE OUTPUT VOLTAGE OF THE TRANSFORMER MUST BE 6VAC FOR THE UNIT TO FUNCTION PROPERLY SLOAN EL 386 OR EL 451 IS RECOMMENDED 120 VAC 6VAC OR ELG 220 220VAC 6VAC 1 Remove one of the knockout caps and route the transformer wire trough it inside ...

Page 4: ...NSTALL WALL PLATE ASSEMBLY Refer Wall Plate Installation Manual 08160044 2021 SLOAN Code No 08160054 Rev 1 11 21 Manufactured by Sloan India Pvt Ltd patents pending SLOAN INDIA PRIVATE LIMITED 344 PHASE II UDYOG VIHAR GURGAON 122015 Phone 91 124 6013300 33 Toll Free 1800 123 3080 customercare sloan in sloan in copyright 2021 Sloan All rights reserved Wall Plate Assembly Installation Manual 0816004...

Reviews: