background image

4

3. INSTALL BATTERY BOX AND SENSOR ASSEMBLY

B.

C.

Di.

Dii.

E.

Connect Solenoid cable 

to sensor assembly

The TruFlush Sensor assembly is designed to work with two options: 
- Hardwire and Battery as a back-up OR 
- Only with Battery power connection. 

A.

 Install the supplied batteries into the battery box. See section 10 to install the batteries into battery box.

B.

 Insert the Battery Box on the right side of the flushometer as shown

 

C.

 Connect Battery Box D-shape connector to Sensor Assembly connector as shown. 

        

NOTE.RED LED WILL START BLINKING WHEN POWER IS CONNECTED TO THE SENSOR ASSEMBLY

D. 

Connect solenoid D-shape connector to sensor assembly. 

E. 

Mount the Sensor Assembly into the wall-bracket. 

        i.Align the 4 slots on the Sensor Assembly with the mounting pegs on the Wall Bracket.

        ii. Slide the Sensor Assembly all the way down.

For Hardwire connection use. 
i. 

Using a wire stripper strip the two wire transformer connection from the conduit.

ii. 

Insert the wire to the Blue Terminal Block provided with the Sensor Assembly 

iii. 

Tighten the terminal block screws using a flathead screwdriver 0.118” (3 mm) or smaller.

 

iv. 

Connect the Blue terminal block to the two pins in the back of the Sensor Assembly.

 
    

  IMPORTANT: SURGE PROTECTOR BEFORE THE TRANSFORMER IS RECOMMENDED

ii.

iv.

WIRING DIAGRAM

One EL-386 Transformer (sold separately) serves one (1) TruFlush 
Closet/Urinal flushometer.
One EL-451 Transformer (sold separately)   serves up to (10) TruFlush 
with 18 gauge wire within 50 feet

One ELG-220 (220 VAC/6 VAC) Transformer (sold separately) serves 
up to (8) TruFlush in parallel

Slide Down

Summary of Contents for TRF 8156-1.28

Page 1: ...8156 1 6 TRF 8156 1 28 TRF 8156 1 1 TRF 8196 0 5 TRF 8196 0 25 TRF 8196 0 125 PRIOR TO INSTALLATION TOOLS REQUIRED FOR INSTALLATION Smooth jawed wrench at least 2 Phillips screwdriver 5 64 hex wrench...

Page 2: ...jaw wrench D Connect outlet pipe not porvided to flushometer Tighten securely with fixed jaw wrench NOTE DO NOT EXERT FORCE ON WALL BOX TO TIGHTEN THE FLUSHOMETER USE FIXED JAW WRENCH TO HOLD THE VALV...

Page 3: ...f the pipe C Remove mud guard by removing the 2 50 mm long truss head screws and discard mud guard NOTE WALL PLATE OPENING MUST BE OF 5 6 X 5 6 142 X 142 MM D Install wall bracket onto flushometer usi...

Page 4: ...racket i Align the 4 slots on the Sensor Assembly with the mounting pegs on the Wall Bracket ii Slide the Sensor Assembly all the way down For Hardwire connection use i Using a wire stripper strip the...

Page 5: ...tart up routine is complete B After the start up routine is complete in the first ten 10 minutes of operation a visible Red LED flashes in the Sensor Window of the TruFlush Flushometer when a user is...

Page 6: ...TTLE WATER FLOW MAY NOT SATISFY THE NEEDS OF THE FIXTURE PROPER ADJUSTMENT IS MADE WHEN PLUMBING FIXTURE IS CLEANSED AFTER EACH FLUSH WITHOUT SPLASHING WATER OUT FROM THE LIP AND A QUIET FLUSHING CYCL...

Page 7: ...m Urinal Models 15 to 34 381 mm to 864 mm The Factory setting should be satisfactory for most installations If the range is too short i e not picking up users or too long i e picking up opposite wall...

Page 8: ...assembly to the solenoid and then press the Override Button to relieve pressure H Disconnect Flushometer solenoid connector from the Sensor Assembly pull on end connector to prevent damage to wires li...

Page 9: ...ee Section 6 Q Put down the Sensor Assembly Override Button R Install Wall Plate See Section 7 13 TROUBLESHOOTING A Sensor Flashes Continuously Only When User Steps Within Range i Unit in Start Up mod...

Page 10: ...Valve Assembly 0 5 gpf 1 9 Lpf 3400108 TRF 8196 0 25 LP Sensor Valve Assembly 0 25 gpf 1 0 Lpf 3400109 TRF 8196 0 125 LP Sensor Valve Assembly 0 125 gpf 0 5 Lpf VALVE ASSEMBLY SELECTION GUIDE Filter S...

Page 11: ...No 1 See Table Valve Assembly Less Plate Page 10 2 See Table Piston Assembly Page 10 3 See Table Activation Assembly Page 10 4a Wall Plate Assembly Sensor Closet 4b Wall Plate Assembly Sensor Urinal...