Using supplied battery compartment hex wrench, remove battery
compartment from the Side Mount unit.
Remove batteries from compartment tray.
Install 4 new C-cell batteries into compartment tray (note position of
batteries in tray), and reinstall compartment tray into the Side Mount
unit.
The Side Mount unit comes preset from the factory. If special
circumstances require adjustment of the activation distance, please
contact Sloan.
The Side Mount unit calibrates upon power up, GREEN and RED
LEDs flash once. The unit will actuate a flush followed by 5 flashes
of GREEN LED. The unit will then perform calibration, a 20 second
sequence, where the GREEN LED flashes quickly. Finally the unit
will start normal operation.
Manual flush button on Side Mount unit allows manual activation
when desired.
DO NOT USE
abrasive or chemical cleaners (including chlorine bleach) to clean side mount unit or flushometer that may
dull the luster and attack the finish. Use ONLY mild soap and water, then wipe dry with clean cloth or towel.
While cleaning the bathroom tile, protect the side mount unit from any splattering of cleaner. Acids and cleaning fluids will
discolor or remove chrome plating.
DO NOT USE
abrasive or chemical cleaners (including chlorine bleach) to clean sensor window that may distort or ruin
the sensor.
1. RED LED continuously flashes when target is present.
The battery is low. Refer to battery replacement instructions.
2. RED LED flashes 4 times after a target has been present for 8 seconds. RED LED flashes once when a target is not present.
The battery is low. Refer to battery replacement instructions.
3. RED LED flashes continuously after calibration.
The unit has failed to calibrate. The optics window is obscured. Remove power, clean window and remove any objects
(barrels, toolboxes, etc.) within close proximity of unit.
Repeat power-up sequence. If unit fails, consult Sloan Technical Support.
When assistance is required, please contact Sloan Technical Support at:
1-888-SLOAN-14 (1-888-756-2614)
-
-
+
+
-
-
+
+
TOP
VIEW
-
-
+
+
-
-
+
+
TOP VIEW
BATTERY REPLACEMENT
TROUBLESHOOTING
CARE AND CLEANING