Soap Dispenser Installation

NOTE: ESD-2100 Shown, instructions applicable for all Sloan soap dispensers

Installing the Touchfree Counter Mounted System

Prior to beginning installation, study the exploded view of the Touchfree Counter-Mounted System and locate all the
pieces. Also, look beneath the countertop to and a suitable place for mounting of the Battery Box (9) so that it will not
interfere with system components or plumbing.

Feed the Data Cable 5a and the
shank of the Dispenser Assembly
1 through the hole in the
countertop. Point the spout of the
Dispenser into the sink bowl.

From underneath the counter,
feed the Lock Washer 3 and then
the Mounting Nut 3a over the
Data Cable 5a and onto the
threaded shank of the Dispenser
Assembly 1. Tighten the nut
securely.

Align the indent inside the top of
the Motor Assembly/Bottle
Support 7 with the indent on the
shank of the Dispenser Assembly
1 and firmly push the Motor
Assembly/Bottle Support up, onto
the shank.

NOTE

: Hold the Data Cable firmly

out of the way as you push up on
the Motor Assembly/Bottle
Support. Continue pushing
upward until the vertical slots in
the Dispenser shank and the
Motor Assembly/Bottle Support
line up.

Secure the Motor Assembly/Bottle
Support 7 to the Dispenser
Assembly 1 shank by pushing the
Retaining Clip 4 into place
through the vertical slots, until it
goes all the way through the Motor
Assembly.

NOTE:

 Motor Assembly Bottle

Support will rotate 360° to avoid
any obstruction.

Remove the cover from the
Battery Box 8 by loosening the
two captive screws on the Battery
Box cover. Position the Box on a
convenient (vertical or horizontal)
surface under the counter top that
will allow access for battery
changing. Attach the Box to the
surface using the two screws 10
and anchors (if attaching to a
plaster or masonry surface).
Use the Wall Clip 11 to secure the
Power Cable to a wall or other
under-counter surface if desired.

Place four alkaline “D” Cell
batteries into the Battery Box 9
cover. The batteries must be
positioned according to the
diagrams shown on the inside of
the cover.

NOTE

: If the batteries are not

properly installed or the cover is
not properly positioned on the
Box, the System will not work.
Position the cover (with batteries
installed) on the Battery Box and
tighten the two captive screws.

IMPORTANT:

 Connect the two

halves of the Data Cable 5a 
and 5b
by visually lining up the white
stripes on each half and gently
pushing the cable connectors
together until the stripes touch.

Improperly assembled
connectors can cause unit to 
not function as intended.

After the batteries are installed in
the battery box, connect the two
halves of the power cable 6a and
6b . Allow 20 seconds before the
system is ready to dispense soap.

Summary of Contents for Optima ETF-80

Page 1: ...oftware from date of first purchase During this period Sloan Valve Company will at its option repair replace or refund the purchase price of any product which fails to conform with this warranty under normal use and service This shall be the sole and exclusive remedy under this warranty Products must be returned to Sloan Valve Company at customer s cost No claims will be allowed for labor transpor...

Page 2: ...ies a two inlet Quick Connect Bak Chek Filter Tee is provided and required as Illustrated Water temperature can be controlled by adjusting the supply stops When connecting the faucet to a single line water supply or a pre tempered water supply a single inlet Quick Connect Bak Chek Filter Tee must be used A Quick Connect Bak Chek Filter Tee must also be used when a Temperature Mixing Valve is inclu...

Page 3: ...lexible Supply Hose Flexible Supply Hose Flexible Supply Hose Faucet Faucet Faucet Single Inlet Filter Assembly Single Inlet Filter Assembly Manifold Assembly Quick Connect Clip Stops Stops Quick Connect Clip Quick Clip Assembly Quick Connect Clip Quick Connect Clip Quick Connect Clip Manifold Assembly Manifold Assembly Stops Control Module with Single Inlet Tee Filter Assembly and Below Deck Manu...

Page 4: ...ASKETS 2 HEX NUTS 2 RUBBER GASKET CHROME COVER PLATE QUICK CONNECT SPOUT HOSE ETF 80 Mid height hardwired EBF 85 Mid height battery FAUCET SENSOR CABLE TRIM PLATE FAUCET GASKET FAUCET RETAINER REVOLVING NUT MOUNTING STUD WATERWAY TUBE QUICK CONNECT SPOUT HOSE ETF 880 Mid height hardwired EBF 187 Mid height battery FAUCET FLAT WASHER LOCK WASHER NUT BASE GASKET TRIM PLATE SPACER MUST BE USED WITH T...

Page 5: ...t 3 5 8 92 mm 2 3 16 56 mm 4 1 2 114 mm 4 1 2 114 mm 6 5 16 160 mm 12 3 4 19 mm ETF 610 EBF 625 Single 3 1 2 89 mm 2 1 12 64 mm 4 1 2 114 mm 4 1 2 114 mm 2 3 16 56 mm 12 3 4 19 mm ETF 660 EBF 665 4 Centerset 3 3 4 95 mm 2 1 4 57 mm 5 1 4 133 mm 5 1 4 133 mm 1 1 2 38 mm 6 3 4 19 mm H G A B C E F H G B C E F H C E F B C B E F G H BELOW DECK CONTROL ROUGH IN DIMENSIONS OPTIMA CONTROL BOX MODEL IMAGE ...

Page 6: ...6 GOOSENECK DECK MOUNTED WALL MOUNTED FAUCET MODEL ROUGH IN DIMENSIONS WITHOUT TRIMPLATE 4 Electrical Box Plaster Ring or 2 Hole for Mounting bracket ...

Page 7: ...eing closest to the faucet and 5 being farthest from the faucet The factory default Sensor Range is 3 A To determine what the current Sensor Range setting is press the red Sensor button on the upper right hand corner of the Optima Control Box for 1 second Five seconds after pressing the button the green LED beside it will blink to indicate the Sensor Range setting For example if it is set at 2 the...

Page 8: ...t adjusted properly Adjust supply stops NOTE For some systems a thermostatic mixing valve may be required SLOAN 10500 SEYMOUR AVENUE FRANKLIN PARK IL 60131 Phone 1 800 982 5839 or 1 847 671 4300 Fax 1 800 447 8329 or 1 847 671 4380 www sloan com 2018 SLOAN Code No 0816843 Rev 1 06 18 If further assistance is required please contact Sloan Tech Support at 1 888 SLOAN 14 1 888 756 2614 DO NOT USE abr...

Page 9: ...ess otherwise noted Sloan Valve Company warrants its Products to be made of first class materials free from defects of material or workmanship under normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced for a period of three years 1 year for SF Faucets special finishes and PWT electronics and 30 days on ...

Page 10: ...hank by pushing the Retaining Clip 4 into place through the vertical slots until it goes all the way through the Motor Assembly NOTE Motor Assembly Bottle Support will rotate 360 to avoid any obstruction Remove the cover from the Battery Box 8 by loosening the two captive screws on the Battery Box cover Position the Box on a convenient vertical or horizontal surface under the counter top that will...

Page 11: ...ck for bent contact pins inside connector 6b If unit is multi activating check for bent contact pins inside connector 6b Refill Removal Grasp the empty Refill Bottle 9 with one hand and use the other hand to push the Green release latch on the Motor Assembly Bottle Support 7 to the right counterclockwise as seen from above Grasp the empty Refill Bottle 9 with one hand and use the other hand to pus...

Page 12: ...4 Parts Breakdown SLOAN 10500 SEYMOUR AVENUE FRANKLIN PARK IL 60131 Phone 1 800 9 VALVE 9 or 1 847 671 4300 Fax 1 800 447 8329 or 1 847 671 4380 www sloan com ...

Reviews: