background image

Code No. 0816843

Rev. 1 (06/18)

INSTALLATION INSTRUCTIONS FOR OPTIMA SENSOR ACTIVATED LAVATORY FAUCETS 

WITH THE OPTIMA CONTROL BOX

GOOSENECK DECK MOUNTED OPTIMA FAUCETS

ETF-600 

Low-height, hardwired

EBF-650 

Low-height, battery

 

ETF-610 

Low-height,hardwired

EBF-615 

Low-height, battery

ETF-660 

Low-height,     

hardwire with side sensor

EBF-665

 Low-height,

battery w/side sensor

 

ETF-80 

Mid-height, hardwired

EBF-85 

Mid-height, battery

 

ETF-880 

Mid-height, hardwired

EBF-187 

Mid-height, battery

 

DECK MOUNTED OPTIMA FAUCETS

ETF-770 

Hardwired with 

side sensor

EBF-775

 Battery with

side sensor

 

ETF-700 

Hardwired

EBF-750 

Battery

 

ETF-700-S 

Hardwired 

with surgical bend

EBF-750-S 

Battery 

with surgical bend

      WALL MOUNTED OPTIMA FAUCETS

ETF-500 

Hardwired

 

EBF-550 

Battery

ETF-800 

Hardwired

EBF-850

 Battery

 

LIMITED WARRANTY

Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and workmanship  
for a period of three (3) years (1 year for SF faucets, special finish and PWT electronics and 30 days on PWT software) from date of first purchase. During this period, Sloan Valve  
Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under normal use and service. This shall be the sole  
and exclusive remedy under this warranty. Products must be returned to Sloan Valve Company, at customer’s cost. No claims will be allowed for labor, transportation or other costs.  
This warranty extends only to persons or organizations who purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does  
not cover the life of the battery.

THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES 
OF ANY MEASURE WHATSOEVER.

TABLE OF CONTENTS

1

ETF-500-S 

Hardwired

with surgical bend

 

EBF-550-S 

Battery

with surgical bend

CONTROL BOX FOR ALL FAUCETS

Control Box w/ 0.5 gpm Turbine

EFP-40-A

Control Box w/1.5 gpm Turbine

EFP-11-A

Control Box w/o Turbine

EFP-39-A

• Prior To Install ..........................................................................  2.

• Mixing Valve Installation ...........................................................  2.

• Important ................................................................................  2.

• Quick Connect Tee ...................................................................  2.

• Tools Required .........................................................................  2.

• Deck Mounted Rough-in ..........................................................  4.

• Wall Mounted Rough-in ............................................................  5.

• Dimensional Data ....................................................................  5.

• Troubleshooting Instructions .....................................................  7.

• Care and Cleaning Instructions .................................................  8.

Summary of Contents for Optima ETF-80

Page 1: ...oftware from date of first purchase During this period Sloan Valve Company will at its option repair replace or refund the purchase price of any product which fails to conform with this warranty under normal use and service This shall be the sole and exclusive remedy under this warranty Products must be returned to Sloan Valve Company at customer s cost No claims will be allowed for labor transpor...

Page 2: ...ies a two inlet Quick Connect Bak Chek Filter Tee is provided and required as Illustrated Water temperature can be controlled by adjusting the supply stops When connecting the faucet to a single line water supply or a pre tempered water supply a single inlet Quick Connect Bak Chek Filter Tee must be used A Quick Connect Bak Chek Filter Tee must also be used when a Temperature Mixing Valve is inclu...

Page 3: ...lexible Supply Hose Flexible Supply Hose Flexible Supply Hose Faucet Faucet Faucet Single Inlet Filter Assembly Single Inlet Filter Assembly Manifold Assembly Quick Connect Clip Stops Stops Quick Connect Clip Quick Clip Assembly Quick Connect Clip Quick Connect Clip Quick Connect Clip Manifold Assembly Manifold Assembly Stops Control Module with Single Inlet Tee Filter Assembly and Below Deck Manu...

Page 4: ...ASKETS 2 HEX NUTS 2 RUBBER GASKET CHROME COVER PLATE QUICK CONNECT SPOUT HOSE ETF 80 Mid height hardwired EBF 85 Mid height battery FAUCET SENSOR CABLE TRIM PLATE FAUCET GASKET FAUCET RETAINER REVOLVING NUT MOUNTING STUD WATERWAY TUBE QUICK CONNECT SPOUT HOSE ETF 880 Mid height hardwired EBF 187 Mid height battery FAUCET FLAT WASHER LOCK WASHER NUT BASE GASKET TRIM PLATE SPACER MUST BE USED WITH T...

Page 5: ...t 3 5 8 92 mm 2 3 16 56 mm 4 1 2 114 mm 4 1 2 114 mm 6 5 16 160 mm 12 3 4 19 mm ETF 610 EBF 625 Single 3 1 2 89 mm 2 1 12 64 mm 4 1 2 114 mm 4 1 2 114 mm 2 3 16 56 mm 12 3 4 19 mm ETF 660 EBF 665 4 Centerset 3 3 4 95 mm 2 1 4 57 mm 5 1 4 133 mm 5 1 4 133 mm 1 1 2 38 mm 6 3 4 19 mm H G A B C E F H G B C E F H C E F B C B E F G H BELOW DECK CONTROL ROUGH IN DIMENSIONS OPTIMA CONTROL BOX MODEL IMAGE ...

Page 6: ...6 GOOSENECK DECK MOUNTED WALL MOUNTED FAUCET MODEL ROUGH IN DIMENSIONS WITHOUT TRIMPLATE 4 Electrical Box Plaster Ring or 2 Hole for Mounting bracket ...

Page 7: ...eing closest to the faucet and 5 being farthest from the faucet The factory default Sensor Range is 3 A To determine what the current Sensor Range setting is press the red Sensor button on the upper right hand corner of the Optima Control Box for 1 second Five seconds after pressing the button the green LED beside it will blink to indicate the Sensor Range setting For example if it is set at 2 the...

Page 8: ...t adjusted properly Adjust supply stops NOTE For some systems a thermostatic mixing valve may be required SLOAN 10500 SEYMOUR AVENUE FRANKLIN PARK IL 60131 Phone 1 800 982 5839 or 1 847 671 4300 Fax 1 800 447 8329 or 1 847 671 4380 www sloan com 2018 SLOAN Code No 0816843 Rev 1 06 18 If further assistance is required please contact Sloan Tech Support at 1 888 SLOAN 14 1 888 756 2614 DO NOT USE abr...

Page 9: ...ess otherwise noted Sloan Valve Company warrants its Products to be made of first class materials free from defects of material or workmanship under normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced for a period of three years 1 year for SF Faucets special finishes and PWT electronics and 30 days on ...

Page 10: ...hank by pushing the Retaining Clip 4 into place through the vertical slots until it goes all the way through the Motor Assembly NOTE Motor Assembly Bottle Support will rotate 360 to avoid any obstruction Remove the cover from the Battery Box 8 by loosening the two captive screws on the Battery Box cover Position the Box on a convenient vertical or horizontal surface under the counter top that will...

Page 11: ...ck for bent contact pins inside connector 6b If unit is multi activating check for bent contact pins inside connector 6b Refill Removal Grasp the empty Refill Bottle 9 with one hand and use the other hand to push the Green release latch on the Motor Assembly Bottle Support 7 to the right counterclockwise as seen from above Grasp the empty Refill Bottle 9 with one hand and use the other hand to pus...

Page 12: ...4 Parts Breakdown SLOAN 10500 SEYMOUR AVENUE FRANKLIN PARK IL 60131 Phone 1 800 9 VALVE 9 or 1 847 671 4300 Fax 1 800 447 8329 or 1 847 671 4380 www sloan com ...