background image

†Zurn® is a registered trademark of Zurco, Inc. Use of “Zurn” is for identification purposes only 

and does not imply affiliation, endorsement, or association between Sloan and Zurco, Inc.

SLOAN • 10500 Seymour Avenue • Franklin Park, 

IL 60131

Phone: +1.800.982.5839 • Fax: +1.800.447.8329 • sloan.com

© 2021 SLOAN VALVE COMPANY 

   

 

 

 

 

Code No. 0816721 –– Rev. 11 (04/21)

The information contained in this document is subject to change without notice.

Item #  Part # 

Description

Items Included with RESS Retrofit and Complete Sloan ECOS Flush Valves

  1 

WES-55-A* 

Cover/Ring/Sensor Assembly - 1.6/1.1 Dual Flush WC

   

WES-60-A*      Cover/Ring/Sensor Assembly - 1,6/1.1w/†Zurn ring Dual Flush WC

   

WES-57-A* 

Cover/Ring/Sensor Assembly 1.28/1.1 - Dual Flush

           EBV-341-A*     Cover/Ring/Sensor Assembly  0.5 & 0.25 Urinal

           EBV-381-A*     Cover/Ring/Sensor Assembly  0.125 Urinal

  2A  EBV-191-A 

Cover Assembly - Dual Flush 

   2B    EBV-142-A       Cover Assembly - Single Flush 

   3A  WES-23-A 

Button Cover Assembly with Screws - Dual Flush

  3B  EBV-130-A 

Single Button Repair Kit

  4 

EBV-131 

Lens Window Cover

  5 

EBV-14 

Locking Ring

   

EBV-30 

Locking Ring - for †Zurn valves

  6 

EBV-196-A*  Module - ECOS Electronic 1.6/1.1 gpf Dual Flush

    

EBV-1054-A*  Module - ECOS Electronic 1.28/1.1 gpf Dual Flush

           EBV-387-A*     Module - ECOS Electronic 0.5 & 0.25 Urinal

           EBV-386-A*     Module - ECOS Electronic 0.125 Urinal 

    7 

EBV-134         Cover Rest Plate

  8 

EBV-145-A 

Inside Cover Assembly (includes solenoid)

 9  EBV-136-A  Solenoid

  10  EBV-1020-A  Flex Tube Diaphragm Assembly 1.6 

           EBV-1024-A  Flex Tube Diaphragm Assembly 1.28

           EBV-1023-A  Flex Tube Diaphragm Assembly 0.5

           EBV-1025-A  Flex Tube Diaphragm Assembly 0.25 & 0.125

   11   

Flush Volume Regulator (included in 10)

  12  EBV-1017-A  Handle Cap (RESS Retrofit Models only)

  13  EBV-91 

Range Adjustment Tool

  14  EBV-22 

Strap Wrench

  15  EBV-137 

7/64” Hex Wrench

  16  WES-19 

English Operation Instruction Plate

    

WES-22 

Spanish Operation Instruction Plate

Items Included with Complete Sloan ECOS Valves Only

  17  H-633-AA 

† † Sweat Solder Kit

  18  H-700-A 

† † Bak-Chek

®

 Control Stop

   19  H-1010-A 

Vandal Resistant Stop Cap

  20  EBV-36-A 

Valve Body

    21A  V-600-AA 

1½” (38 mm) x 10” (254 mm) Vacuum Breaker 

(Model 8110 & 8111)

   

V-600-AA 

1½” (38 mm) x 23” (584 mm) Vacuum Breaker (Model 8115)

   

V-600-AA 

1½” (38 mm) x 26” (660 mm) Vacuum Breaker (Model 8116)

   21B  V-600-AA 

¾” (19 mm) Vacuum Breaker (Model 8186) (Urinal Models)

   22A  F-5-AT 

1½” Spud Coupling Assembly (Water Closet Models)

  22B  F-5-AW 

¾” Spud Coupling Assembly (Model 8186) (Urinal Models)

5

1

7

8

9

10

20

14

15

13

11

6

12

16

4

19

21A

21B

2

22A

22B

3A

3B

17A

18A

PARTS LIST

Manufactured in the U.S.A. by Sloan Valve Company under one or more of the 

following patents: U.S. Patents. 4,839,039; 5,195,720; 5,295,655; 5,542,718; 

5,558,120; 5,564,460; 5,887,848; 5,967,182; 6,212,697; 6,382,586; 6,619,614; 

6,685,158; 6,691,979; Des. 411,609. 
Other Pats. Pending. BAK-CHEK

®

, CID

®

, COURTESY FLUSH

®

, PARA-FLO

®

, PERMEX

®

TURBO-FLO

®

.

When further assistance is required, 

please contact Sloan Technical Support at: 

+1.888.SLOAN.14 (+1.888.756.2614) or visit us online at: sloan.com

*-BT Sloan Connected Product Models Available

This equipment has been tested and found to comply with the limits 

for a class B digital devices, pursuant to Part 15 of the FCC Rules. 

These limits are designed to provide reasonable protection against 

harmfull interference in a residential installation. This equipment 

generates, uses, and can radiate radio frequency energy and, if not 

installed and used in accordance with the instruction manual, may 

cause harmul interference to radio or television reception, which 

can be determined by turning the equipment off and on, the user is 
encouraged  to try to correct the interference by one or more of the 

following measures: 

FCC INFORMATION TO USERS

                            Reorient or relocate the receiving antenna
                            Increase the separation between the equipment and receiver
                            Connect the equipment into an outlet on a circuit different from 
                            that to which the receiver is connected
                            Consult the dealer or an experienced radio/TV technician for help

•   

•   

•   

•   

† † Contact Tech Support for Available Sizes

Summary of Contents for ECOS HET 8100 Series

Page 1: ...WHEN INSTALLING A FLUSHOMETER IT IS IMPORTANT THAT THE FLUSH MODEL MATCHES THE REQUIREMENTS OF THE PLUMBING FIXTURE FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS The Sloan ECOS is designed to oper...

Page 2: ...allation Model 8110 8111 Reference for RESS C Retrofit Model 8115 8116 valves are designed for installations where the water supply is roughed in 24 27 610 mm 686 mm above the top of the water closet...

Page 3: ...Sweat solder the Adapter to pipe WITH THE EXCEPTION OF CONTROL STOP INLET DO NOT USE PIPE SEALANT OR PLUMBING GREASE ON ANY VALVE COMPONENT OR COUPLING IMPORTANT BAK CHEK CONTROL STOP COVER TUBE IRON...

Page 4: ...and Spud Flange over Vacuum Breaker Tube B Insert Tube into Fixture Spud C Hand tighten Spud Coupling onto Fixture Spud G 44 FRICTION RING C L SUPPLY ADJUSTABLE TAILPIECE C L FIXTURE CONTROL STOP O RI...

Page 5: ...fitting the Optima Plus onto a Zurn valve body a special Locking Ring must be used identified by a machined groove around the ring Order the Optima Plus with the Z variation to receive the unit suppli...

Page 6: ...w may not satisfy the needs of the fixture Proper adjustment is made when plumbing fixture is cleansed after each flush without splashing water out from the lip AND a quiet flushing cycle is achieved...

Page 7: ...xture Replace with proper G2 ECOS model or refer to the G2 ECOS Conversion Guide to convert existing unit to the proper model D Dirt in diaphragm bypass Clean under running water or replace flex tube...

Page 8: ...ete Sloan ECOS Valves Only 17 H 633 AA Sweat Solder Kit 18 H 700 A Bak Chek Control Stop 19 H 1010 A Vandal Resistant Stop Cap 20 EBV 36 A Valve Body 21A V 600 AA 1 38 mm x 10 254 mm Vacuum Breaker Mo...

Reviews: