Repair Parts and Maintenance Guide
The information contained in this document is subject to change without notice.
Code No.
Description
0344067
ELG SENSOR ASM 0.5 LPF
ELG
SENSOR ASM
SELECTION GUIDE
$&7,9$7,21$66(0%/<5(3$,5.,7
3,6721$66(0%/<5(3$,5.,7
1.
BATTERY REPLACEM
ENT
-
-
+
+
+
-
When required, replace batteries with four (4) Alkaline AA-Size Batteries.
NOTE: WATER DOES NOT HAVE TO BE TURNED OFF TO REPLACE BATTERIES. USE ALKALINE BATTERIES FOR PROPER UNIT
OPERATION.
A.
Loosen Set Screw at bottom of Wall Plate &
Remove Wall Plate
B.
Disconnect Battery Pack from Sensor
Assembly
.
C.
Remove battery box from inside the Wall Box
D.
Remove the battery box cover by loosening screw using a Philips head screwdriver.
E.
Replace the batteries with 4 new AA Alkaline batteries as shown.
F.
Reinstall the Battery cover and using a screwdriver tighten the screw until the battery cover is tightly secure.
G.
Insert the Battery Compartment into the Battery Compartment Slot of the Wall Box.
H.
Connect the Battery Pack to the connector located on the Sensor Assembly
I.
Install Wall Plate and secure with Set Screw.
2
0344080
ELG SENSOR ASM 1 LPF
0344081
ELG SENSOR ASM 1.5 LPF
2
.
FILTER CLEANING AND REPLACEMENT
A.
Loosen Set Screw at bottom of Wall Plate &
Remove Wall Plate
B.
Turn off water and activate Solenoid Valve to release water
pressure.
C.
Disconnect Battery Pack and Solenoid Coil from Sensor .
D.
Unscrew Inlet and Outlet Coupling from Solenoid Valve and
remove Solenoid Valve from Wall Box.
E.
Remove Filter Assembly and rinse out or replace with new Filter
Assembly.
F.
Reinstall Filter Assembly into Valve Body.
G.
Make sure Outlet Seal is installed in outlet end of Valve Body.
H.
Reinstall Solenoid Valve into Wall Box. Make sure arrow on Valve
Body faces direction of water flow.
I.
Reconnect all Couplings and Electrical Connections.
J.
Install Wall Plate and secure with Set Screw.
Sensor Urinal Flush Valve (Hardwired/Battery)