TROUBLESHOOTING

Inflator does not turn on:

1.  The fuse, located in the plug adapter, may have 

blown. Unscrew the tip of the plug adapter, remove 
fuse and inspect. If necessary, replace fuse with 
one of the same size and amperage.

2.  Check vehicle's power outlet fuse; it should be a minimum of 15 amps.
3.  Check receptacle and plug terminals for dirt (particularly tobacco). Use a non-conductive 

probe (not fingers or metal) to dislodge and remove debris.

4.  Push the power plug firmly into the receptacle and twist it back and forth.

Inflator runs but does not inflate:

1.  Be sure the air hose connector is tightly screwed onto the valve stem.
2.  Check tire for leaks. Check hose for breaks and leaks at fittings.

Inflator runs slowly:

1.  The inflator may have overheated from excessive use. Shut it off and allow it to cool for 

25 minutes. 

2.  The voltage may be too low. Check the condition of your vehicle's battery.

NOTE:

  If  tire  is  totally  deflated,  it  is  possible  that  the  tire  could  separate  from  the  rim 

allowing air to leak out when trying to inflate. In the event this occurs, it may be necessary 
to jack up the tire prior to inflation. 

Warranty: For the period of one year from date of purchase, manufacturer guarantees that this Product will meet the 
specifications when used as directed. Manufacturer’s sole liability and Customer’s sole remedy under any warranty 
claim is limited to a Manufacturer’s coupon for a replacement product upon return of unit and proof of purchase.
QUESTIONS OR COMMENTS: Call 

+1-805-489-0490

 or visit www.slime.com

ITW Global Tire Repair • 

125

 Venture Drive, Suite 

210

, San Luis Obispo, CA 

93401

 USA

Slime® 

is a 

trademark of Illinois Tool Works, Inc., registered in the U.S. and other countries.

Summary of Contents for 40050

Page 1: ...PART 40050 01 17 17 CARS LIGHT TRUCKS SUVS TIRE INFLATOR ATTENTION READ ALL INSTRUCTIONS CAREFULLY FAILURE TO FOLLOW WARNING INSTRUCTIONS CAN RESULT IN FIRE PERSONAL INJURY OR PROPERTY DAMAGE ...

Page 2: ... into 12V power outlet AIR ADAPTER STORAGE Inflatables adapters snap in place for easy access FLOATY BALL TECH SPECS IDEAL USES TIRE INFLATION TIME CFM AIR HOSE LENGTH POWER CORD LENGTH POWER SOURCE GAUGE LIGHT 0 35 PSI Standard Tire P195 65 R15 Tires 8 min 0 49 13 9 LPM 2 ft 0 6m 10 ft 3m 12 volt accessory power outlet Dial gauge LED AIR HOSE ...

Page 3: ...ating You may need to be in accessory or on position Please make sure emergency brake is set and car is in park Always ensure air hose chuck touches the core of the valve stem for proper inflation 2 DO NOT use inflator continuously for more than 10 minutes Allow unit to cool approximately 25 minutes between uses Do not leave inflator unattended 3 ALWAYS use a pressure gauge to check tire pressure ...

Page 4: ...ted from excessive use Shut it off and allow it to cool for 25 minutes 2 The voltage may be too low Check the condition of your vehicle s battery NOTE If tire is totally deflated it is possible that the tire could separate from the rim allowing air to leak out when trying to inflate In the event this occurs it may be necessary to jack up the tire prior to inflation Warranty For the period of one y...

Page 5: ...ATENCIÓN LEA TODAS LAS INSTRUCCIONES CON ATENCIÓN SI NO SIGUE LAS INSTRUCCIONES DE ADVERTENCIA PUEDE CAUSAR INCENDIO LESIONES A PERSONAS O DAÑOS MATERIALES AUTOS CAMIONES LIGEROS SUV INFLADOR DE LLANTAS ...

Page 6: ...es inflables se insertan en su lugar para fácil acceso GLOBO ESFERA MEDIDOR DE CUADRANTE Rango de 0 a 100 PSI ESPECIFICACIONES USOS IDEALES TIEMPO DE INFLADO DE LLANTAS PCM LONGITUD DE MANGUERA DE AIRE DE ROLLO LONGITUD DEL CORDÓN DE CORRIENTE FUENTE DE ENERGÍA INDICADOR LUZ Llantas 8 min 0 49 13 9 LPM 2 ft 0 6 m 10 ft 3 0 m Toma de corriente para accesorio de 12 voltios Indicador de cuadrante en ...

Page 7: ...do Puede ser necesario tenerlo en la posición de accesorios o encendido Asegúrese de haber puesto el freno de emergencia y de tener la palanca de cambios en la posición de estacionado park Siempre asegúrese de que el mandril de la manguera toque el centro del vástago de la válvula para inflar correctamente 2 NO USE el inflador continuamente durante más de 10 minutos Permita que la unidad se enfríe...

Page 8: ...de estar sobrecalentado debido a uso excesivo Apáguelo y espere 25 minutos para que se enfríe 2 El voltaje puede ser demasiado bajo Revise la condición de la batería de su vehículo NOTA Si la llanta está totalmente desinflada es posible que esté separada del aro y éste permite que el aire se escape cuando trata de inflarla Si ocurre esta situación puede ser necesario levantar la llanta con un gato...

Reviews: