The Instructions are for Freedom Units made with the IDEC PLC unit
Page 6
January, 2022
Delay Time setting to expire and then spraying for the duration of the
Spray Time setting. This will repeat indefinitely.
Proper Automatic Sequence of Operation
1.
The proximity sensor detects machine cycles as they occur (mold
open).
2.
The control box PLC tracks the number of cycles (Counter 1 &
Counter 2) between applications of material through the spray
nozzles.
3.
When the number of cycles selected is reached (and the
proximity switch detects the mold open), the Delay Time 1 &
Delay Time 2 begin timing before the spray nozzles actuate and
release the spray.
4.
Upon reaching the set Delay Time, the spray head valves will
open and release the spray for the duration of time called for by
the Spray Time 1 & Spray Time 2 settings.
The
Red Indicator Light
on the top of the spray unit serves two
functions. When the pressure in the supply cylinder becomes low, the
red light will turn on and illuminate steadily. This indicates that the
cylinder is nearing empty and needs to be replaced. Depending on the
Spray Time duration setting, there will be approx. 15-20 sprays
remaining when light turns to a steady red. The
Red Indicator Light
will also illuminate when the spray heads are releasing spray. The
light will turn on solid when the pressure pot is empty (if using the
pressure pot option).
For Manual Spray Head Activation
From the main Time/Date screen, hit the left arrow button and
release.
The below screen with 4 arrows will display on the screen. The top
right of display screen will show 9/9: