SLEIPNER MOTOR AS Side-Power Automatic Main Switch Installation Manual Download Page 3

 3

5169

2

2020

-

It is the installers responsibility 

When installing Side-Power equipment to follow the outlined regulations/ classifi cation rules (electrical/ mechanical) according to 

international or special national regulations. Instructions in this guide cannot be guaranteed to comply with global electric/ mechanic 

regulations/ classifi cation rules.

To follow all health and safety laws in accordance with their local outlined regulations/ classifi cation rules. 

Before installation, it is important that the installer reads this guide to ensure necessary acquaintance with this product. 

The recommendations made in this manual are guidelines ONLY, and Sleipner Motor AS (Side-Power) strongly recommend that 

before installation, advice is obtained from a naval architect familiar with the particular vessel and regulations/ classifi cations.

    This manual is intended to support educated/ experienced staff  and is therefore not suffi  cient in all details for professional 

installation. 

(NB: These instructions are only general instruction. If you are not skilled to do this work, please contact professional 

installers for assistance.)

    All electrical work must be done by a licensed professional. 

Faulty installation of the tunnel, thruster or panel will render all warranty given by Sleipner Motor AS void.

MC_0038

MC_0273

Considerations and Precautions

EN

•  Install the automatic main switch as close to the battery(ies) as possible.

•  Do not connect the Sleipner automatic main switch with other products than appropriate original Sidepower control panels or other Sidepower control  

  devices. (NB: Sleipner products are specifi cally designed with a separate fi fth control cable for the automatic main switch.)

•  The automatic main switch must be installed so that it keeps dry at all times.

•  The automatic main switch can NOT be fi tted in spaces requiring Ignition protected equipment.

•  Ensure to use the correct fuse for the main switch depending on the thruster model installed.

IMPORTANT

This manual is to be used in addition to the regular installation manual for the Sidepower thruster. This manual is intended for professionals only.

Summary of Contents for Side-Power Automatic Main Switch

Page 1: ...Made in Norway Sleipner Motor AS 2020 SLEIPNER MOTOR AS P O Box 519 N 1612 Fredrikstad Norway www side power com Document id Revision Date 5169 2 Installation Manual Automatic Main Switch S Link 2020...

Page 2: ...l health and safety requirements according to DIRECTIVE 2013 53 EU DIRECTIVE 2014 30 EU DIRECTIVE 2014 35 EU MC_0020 Installation Instructions Considerations and Precautions 3 Measurements 4 Specifica...

Page 3: ...nal installation NB These instructions are only general instruction If you are not skilled to do this work please contact professional installers for assistance All electrical work must be done by a l...

Page 4: ...6 L Length 205 8 1 W Width 79 3 11 W Width including fasteners 90 3 54 a Attachment hole from the top 51 5 2 03 b Attachment hole from the bottom 92 8 3 65 c Attachment hole from the side 37 5 1 5 d D...

Page 5: ...5 5169 2 2020 MG_0327 Manual over ride button Push to shut OFF Pull to activate ON Fuse holder Main cable s from battery ies Main cable s to the thruster Automatic Main Switch EN...

Page 6: ...el bolts Fitting the thruster cables 5 Remove the nuts and washers 6 Fit the cable cables as shown directly onto the pre fitted conductor 7 Assemble the washers in the sequence shown 8 Tighten the end...

Page 7: ...for deciding the main cable sizes the lengths are the total of positive and negative from the battery Please refer to the graphic for special considerations relating to your model MG_0328 12 24V 5A S...

Page 8: ...off switch is not required The S Link cable must be connected to the S Link network on the Automatic Main Switch assigned to be bow or stern IMPORTANT Fit only one thruster to each automatic main swi...

Page 9: ...ctivate Fuse is blown Replace the fuse or check if the main cable from the battery and main cable to the thruster Communication fail The panel has no communication with the main switch Check S link or...

Page 10: ...nt supplier that the installation instructions of the Installation and Operation Manual have been complied with and that the defect remains e warranty service shall be performed only by the Warrantor...

Page 11: ...11 5169 2 2020 MC_0037 Notes EN...

Page 12: ...cument was correct at the time it was published However Sleipner Motor AS can not accept liability for any inaccuracies or omissions it may contain Continuous product improvement may change the produc...

Reviews: