Test Results

After a test has been performed, the test results will be indicated on the front panel display.

PASS:  

If the DUT passes the test, you will hear a short audible beep and the display will 

indicate the test results.

FAIL:

   If a failure occurs, you will hear a long audible alarm and the red flashing indicator 

will light up. To stop the alarm press the red RESET button.   

Summary of Contents for 2900 Series

Page 1: ...R DEATH THESE SAFETY PROCEDURES MUST BE STRICTLY OBSERVED WHEN HANDLING AND USING A TEST INSTRUMENT SAFETY CHECKLIST KEEP unqualified unauthorized personnel away from the test area ARRANGE test stations in a safe and orderly manner NEVER touch products or connections during a test STOP the test first in the event of a problem NEVER perform a Ground Bond test on energized circuitry or equipment BE ...

Page 2: ...ard through the setup menus UP DOWN ARROW KEYS Use these keys to cycle through the test parameter setup EXIT KEY Use this key to exit any menu HIGH VOLTAGE OUTPUT TERMINAL Provides the high voltage used during a Hipot test Connector used to attach the high voltage test lead adapter box high voltage lead or test fixture high voltage lead to the instrument HIGH VOLTAGE INDICATOR Indicator flashes to...

Page 3: ...ge the fuse unplug the power mains cord and turn the fuse receptacle counterclockwise The fuse compartment will be exposed Please replace the fuse with one of the proper rating INPUT POWER RECEPTACLE Standard IEC 320 connector for connection to a standard NEMA style line power mains cord VOLTAGE SELECT SWITCH Sets the line voltage configuration of the instrument In the left position it is set for ...

Page 4: ... style line power mains cord into the input power receptacle on the rear panel of the instrument and plug the male end of the cord into a grounded power source 3 Connect the Interlock Disable key to the Remote Input connector on the back panel of the instrument This is required in order to run a test 4 Turn the instrument power switch ON Upon power up you will see the Slaughter company name model ...

Page 5: ...reen 4 Editing Test Parameters Default test type parameters are shown below Input Voltage 115 or 230 volts AC country specific Lock OFF Test W I 2975 AC Dielectric Withstand Test Mode Voltage Output 1 240 volts AC High Current Trip HI LMT 10 mA Low Current Trip LO LMT 0 mA Ramp Timer 0 1 second Dwell Timer 1 second AC Output Freq 60Hz Continuity OFF DC Dielectric Withstand Test Mode Voltage Output...

Page 6: ...second black return lead 102 069 904 to the front panel continuity check terminal and connect the other end of the lead to the third prong on the line cord coming from the DUT Connect either the high voltage lead 102 055 913 or high voltage probe 102 050 913 whichever one you are using for your application into the high voltage terminal located on the front panel and connect the other end of the c...

Page 7: ...t panel return output terminal and connect the other end of the lead to the dead metal on the chassis of the DUT Connect the high voltage lead from the adapter box to the front panel high voltage terminal Connect the continuity lead from the adapter box to the front panel continuity check terminal Plug your DUT into the adapter box 1 2 3 4 RESET POWER TEST SET EXIT HIPOT TESTER CAUTION 5KVAC MAX 6...

Page 8: ...x_Support Test Results After a test has been performed the test results will be indicated on the front panel display PASS If the DUT passes the test you will hear a short audible beep and the display will indicate the test results FAIL If a failure occurs you will hear a long audible alarm and the red flashing indicator will light up To stop the alarm press the red RESET button ...

Reviews: