19
Installation Manual
Note:
●
All wires of indoor unit and outdoor unit should be connected by a professional.
●
If the longth of power connection wire is insufficient, please contact the supplier for a new one. Avoid extending the wire by yourself.
●
For the air conditioner with plug, the plug should be reachable after finishing installation.
●
For the air conditioner without plug, an air switch must be installed in the line. The air switch should be all-pole partingand the
contact parting distance should be more than 3mm.
(5)
Put wiring cover back and then tighten the screw.
(6)
Put back the cover and panel.
(3)
Bind them evenly.
(4)
The liquid pipe and gas pipe should be bound separately at the end.
Note:
●
The power cord and control wire can't be crossed or winding.
●
The drain hose should be bound at the bottom.
Outdoor unit connection
L
N
S
yellow-
green
Button
Screw
Clasp
Clasp
8. Band up pipe
(1)
Bind up the connection pipe, power cord and drain hose with the band.
(2)
Reserve a certain length of drain hose and power cord for installation when binding them. When binding to a certain degree,
separate the indoor power and then separate the drain hose.
drain hose band
connection pipe
indoor power cord
gas
pipe
indoor and
outdoor power cord
liquid pipe
drain hose
band