15
Installation of the Unit
2. Electrical Wiring
(1). For solid core wiring (Fig.13)
1). Cut the wire end with a wire cutter or wire-cutting pliers, then strip the insulation about
25mm (15/16") .
2). Using a screwdriver, remove the terminal screw(s) on the terminal board.
3). Using pliers, bend the solid wire to form a loop suitable for the terminal screw.
4). Shape the loop wire properly, place it on the terminal board and tighten securely with
the terminal screw using a screwdriver.
(2). For strand wiring (Fig.13)
1). Cut the wire end with a wire cutter or wire-cutting pliers, then strip the insulation about
10mm (3/8") .
2). Using a screwdriver, remove the terminal screw(s) on the terminal board.
3). Using a round terminal fastener or pliers, securely clamp a round terminal to each
stripped wire end.
4). Position the round terminal wire, and replace and tighten the terminal screw with a
screwdriver.(Fig.14)
(3). How to fix connection cord and power cord by cord clamp
After passing the connection cord and power cord through the insulation tube, fasten it with
the cord clamp.(Fig.15)
Solid wire
Strand wire
Solderless terminal
Insulation laver
Fig.14
Fig.13
Fig.15
Screw with
special washer
Wire
Wire
Terminal
board
Round
terminal
Round
terminal
Insulation tube
Insulation tube
Cord clamp