background image

6

Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com

Rev. 0.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 5, 2021

3.5.  ClockBuilder Desktop Software Description

There are several programs to control the Si5356 device. These are available by clicking 

Start 



Programs 



Silicon Laboratories 



ClockBuilder Desktop Software X.X

, where X.X is the software

version number. There is a detailed user guide accessible here and in the 

Help

 

 

Help Menu

 option of the

software.

3.6.  USBXpress Driver Installation

The EVB uses the Silicon Laboratories' USBXpress driver to allow the EVB to communicate with the computer via
USB.

The driver is installed after the EVB software is installed. Click 

Install

 to run the driver installation. Clicking 

Cancel

will not install any files, and the EVB will not work with the software.

Figure 4. Driver Installer Dialog

Note:

If the driver has already been installed on the computer before, it will not be reinstalled, and a message box will appear
as shown in Figure 5.

Figure 5. Driver Already Installed

The installer will copy the necessary driver files and update the operating system. However, for every different EVB
connected to the same computer, the hardware installation wizard will run to associate this driver with the new
EVB. Let the wizard run with its default settings. Figure 6 shows a successful driver installation.

Table 1. Programs

Program

Description

ClockBuilder Desktop

This automatically programs the necessary registers based on the customer's 
desired frequency plan for the Si5356 device.

Bit Field Programmer

This utility provides access to each bit field in the register map of the device; no 
masking and shifting is required to decode each setting or control in the register 
map.

Register Programmer

This provides low-level control of the device with individual 8-bit register accesses.

Summary of Contents for Si5356

Page 1: ...z quad frequency 8 output clock generator EVB Features Fully powered from a single USB port On board 25 MHz XTAL allows standalone asynchronous operation GUI programmable VDD supply allows device to operate from 3 3 V 2 5 V or 1 8 V core GUI programmable VDDO supplies allows each of the four banks of outputs to have its own supply voltage selectable from 3 3 V 2 5 V and 1 8 V GUI controlled voltag...

Page 2: ...n controls the voltage regulators monitors the INTR pin and controls the three status LEDs There are five programmable voltage regulators VDD VDDOA VDDOB VDDOC VDDOD which supply power to the Si5356 device VDD and VDDO jumpers allow the option of powering the device from external supplies or as a convenient point for measuring current I2 C jumpers allow disconnecting the Si5356 from the I2 C bus t...

Page 3: ... swings below ground level 2 2 2 On board XTAL The on board 25 MHz allows the Si5356 EVB to generate asynchronous clocks To use this option select the XTAL input from the Si5356 ClockBuilder Desktop software 2 3 Outputs CLK0 CLK7 Each of the eight output clocks can be accessed using SMA connectors The outputs are dc coupled no in line dc blocking capacitors between the output pin and the SMA conne...

Page 4: ...amework is required before installing and running the software Details and installation information about the NET Framework are available via a shortcut in the NETFramework directory or at the following web site http www microsoft com downloads details aspx FamilyId 262D25E3 F589 4842 8157 034D1E7CF3A3 displaylang en There are multiple versions of the NET Framework available from Microsoft and the...

Page 5: ...021 3 4 ClockBuilder Desktop Software Uninstall Instructions Close all the programs and help files before running the uninstaller to ensure complete removal of the software The driver software must be uninstalled separately See 3 6 USBXpress Driver Installation for details To uninstall the software use the Add and Remove Programs utility in the Control Panel as shown in Figure 3 Figure 3 Uninstall...

Page 6: ...iles and the EVB will not work with the software Figure 4 Driver Installer Dialog Note If the driver has already been installed on the computer before it will not be reinstalled and a message box will appear as shown in Figure 5 Figure 5 Driver Already Installed The installer will copy the necessary driver files and update the operating system However for every different EVB connected to the same ...

Page 7: ...76 3000 Fax 781 376 3100 sales skyworksinc com www skyworksinc com 7 Rev 0 2 Skyworks Proprietary Information Products and Product Information are Subject to Change Without Notice November 5 2021 Figure 6 Successful Driver Installation ...

Page 8: ...ed via the Add and Remove Programs utility in the Control Panel Locate the entry called Silicon Laboratories USBXpress Device Click the button and it should show the version and location of what it will remove Figure 7 Driver Uninstall Location The USBXpress installation files are located with the ClockBuilder Desktop Software The driver files for the EVB may be reinstalled from this location or b...

Page 9: ...J1 SMA CLK0 J1 SMA CLK0 R17 2 15K R17 2 15K R20 1K R20 1K R16 2 15K R16 2 15K R4 0 R4 0 U1 Si5356 U1 Si5356 EPAD 25 CLK4 14 I2C_LSB 3 OEB 6 CLKIN 4 SSC_DIS 5 XB 2 XA 1 CLK3 17 CLK2 18 CLK1 21 CLK0 22 VDD 24 VDDOA 20 VDDOB 16 VDDOC 15 VDDOD 11 VDD 7 INTR 8 SCL 12 SDA 19 GND 23 CLK7 9 CLK6 10 CLK5 13 J5 SMA CLK3 J5 SMA CLK3 R23 0 R23 0 R2 0 R2 0 J7 HEADER 2x3 J7 HEADER 2x3 1 3 2 4 5 6 J10 SMA CLK7 J...

Page 10: ... 0 1uF C10 0 1uF C18 0 1uF C18 0 1uF R44 220 R44 220 S1 SW PUSHBUTTON S1 SW PUSHBUTTON R43 220 R43 220 R29 2K R29 2K C20 1uF C20 1uF R30 2K R30 2K R41 1K R41 1K C15 1uF C15 1uF D3 MMBD3004S 7 F D3 MMBD3004S 7 F R28 1K R28 1K U5 C8051F340 U5 C8051F340 VDD 10 REGIN 11 GND 7 VBUS 12 D 8 D 9 P0 0 6 P0 1 5 P0 2 4 P0 3 3 P0 4 2 P0 5 1 P0 6 48 P0 7 47 P1 0 46 P1 1 45 P1 2 44 P1 3 43 P1 4 42 P1 5 41 P1 6 ...

Page 11: ...NC O2 17 SDO O1 16 VLOGIC 10 CSB AD0 13 RESB AD1 14 SHDN_B 15 VDD 7 DIS 9 SDI SDA 11 CLK SCL 12 VSS 18 C39 1uF C39 1uF TP13 GND RED TP13 GND RED C25 10uF C25 10uF U15 MAX8869 U15 MAX8869 GND 10 IN 4 OUT 12 RSTB 6 SET 11 SHDNB 7 IN 5 IN 3 IN 2 OUT 13 OUT 14 OUT 15 SS 8 NC 16 NC 9 NC 1 EPAD 17 C22 1uF C22 1uF R49 10 R49 10 C33 10uF C33 10uF C49 1uF C49 1uF TP12 GND RED TP12 GND RED R55 10K R55 10K U...

Page 12: ...met B45196H5106M309 5 17 C22 C23 C24 C26 C28 C29 C31 C32 C34 C35 C36 C39 C44 C45 C47 C49 C52 1 µF 10 V 10 C0603 Venkel C0603X7R100 105K 6 6 C37 C38 C41 C42 C50 C53 0 01 µF 10 V 20 C0402 Venkel C0402X7R100 103M 7 1 D1 RED LED S GW KA Panasonic LN1271RAL 8 2 D2 D3 MMBD3004S 7 F 300 V SOT23 AKC Diodes Inc MMBD3004S 7 F 9 2 D4 D5 GREEN LED S GW AK Panasonic LN1371G 10 8 J1 J2 J3 J5 J6 J8 J9 J10 SMA SM...

Page 13: ...5 R2512 Venkel CR2512 2W 10R0D 27 4 R52 R53 R55 R56 10 k 5 R0402 Venkel CR0402 16W 103J 28 1 R57 47 5 k 1 R0603 Venkel CR0603 10W 4752F 29 1 R58 15 4 k 1 R0603 Venkel CR0603 10W 1542F 30 1 S1 SW PUSHBUTTON 12 Vdc SW PB MOM Mountain Switch 101 0161 EV 31 1 TP4 Black TESTPOINT Kobiconn 151 203 RC 32 1 U1 Si5356 3 3 V QFN24N4X4P0 5 Skyworks Si5356 A A GM 33 1 U2 25 MHz XTAL4N3 2X2 5 FA238 Epson FA 23...

Page 14: ...SPC Technology 2397 41 4 Richco NSS 4 4 01 42 10 Jumpers Sullins SPC02SYAN 43 1 C21 10 µF 25 V 20 6032_EIAC Kemet B45196H5106M309 44 1 J4 SMA SMA EDGE 5 Johnson Components 142 0701 801 45 1 R7 0 R0402 Venkel CR0402 16W 000 46 13 TP1 TP2 TP3 TP5 TP6 TP7 TP8 TP9 TP10 TP11 TP12 TP13 TP14 RED TESTPOINT Kobiconn 151 207 RC Table 2 Si5356 EVB Bill of Materials Continued Item Qty Reference Value Voltage ...

Page 15: ... and Product Information are Subject to Change Without Notice November 5 2021 DOCUMENT CHANGE LIST Revision 0 1 to Revision 0 2 Changed Any Rate Clock Generator to ClockBuilder Desktop throughout Changed MultiSynth Clock Programmer to ClockBuilder Desktop throughout Updated Figure 3 on page 5 Removed Uninstaller Option figure Updated Figure 8 on page 8 ...

Page 16: ...RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Skyworks products are not intended for use in medical lifesaving or life sustaining applications or other equipment in which the failure of the Skyworks products could lead to personal injury death physical or environmental damage Skyworks customers using or selling Skyworks products for use in such applications do so at the...