Voltage Requirements
11 to 30 VDC nominal (airplane power)
Absolute Maximum Voltage
40 VDC
Power Requirements
1 A at 14 VDC, 0.5A at 28 VDC when charging
TEMPERATURE RANGE
– OPERATIONAL
Batteries Installed
-20 °C to 60 °C
Batteries Removed
-30 °C to 60 °C
Batteries Charging
0 to 45 °C
TEMPERATURE RANGE
– STORAGE
Batteries Installed
-20 °C to 50 °C
Batteries Removed
-40 °C to 85 °C**
** Storage at high temperatures for an extended period of time will decrease the life time of onboard components
including the internal battery.
NOTE:
Operation with extended temperature range:
The limiting factor for the operational temperature range of the unit is the temperature rating of the Li-Ion batteries.
When using the unit at extreme temperatures, STS recommends removing the batteries (see DOC 0595 Battery
Removal Instructions) allowing the unit to run within a wider temperature window. Please also refer to DOC 0595
for proper handling procedures of the circuit board