Figure 3
. MT (Match Throw) plumbing diagram.
Cradle Bracket
Cradle Bracket
Incoming Gas Line
Key Valve
NOTE: It is required to install seperate key valves
when lighting a MT model to ensure each burner is
lit safely.
Two key valves are required to enable safe lighting of individual burners or you will void the warranty. Without them you
risk delayed ignition of the one burner not being lit at the same time. It is highly recommended to keep the key valves with
in 6-feet of each other and on the same side. See Match Throw lighting instructions below.
REV. 4-6-16
Model
Model
Minimum Rough Opening
Total Btu’s
NG
Total Btu’s
LP
FPB-36LTFS
+ FPB-36LTFS
=
76.25” long x 6.875” wide
110,000
110,000
FPB-36LMT
+ FPB-36LMT
=
76.25” long x 6.875” wide
104,000
104,000
FPB-36LTFS
+ FPB-30LTFS
=
70.25” long x 6.875” wide
97,000
97,000
FPB-36LMT
+ FPB-30LMT
=
70.25” long x 6.875” wide
97,000
100,000
FPB-36LTFS
+ FPB-24LTFS
=
64.25” long x 6.875” wide
90,000
90,000
FPB-36LMT
+ FPB-24LMT
=
64.25” long x 6.875” wide
87,000
90,000
FPB30L-TFS
+ FPB30L-TFS
=
64.25” long x 6.875” wide
84,000
84,000
FPB30L-MT
+ FPB30L-MT
=
64.25” long x 6.875” wide
90,000
90,000
FPB30L-TFS
+ FPB24L-TFS
=
58.25” long x 6.875” wide
77,000
77,000
FPB30L-MT
+ FPB24L-MT
=
58.25” long x 6.875” wide
80,000
80,000
FPB-24LTFS
+ FPB-24LTFS
=
52.25” long x 6.875” wide
70,000
70,000
Table 1
IMPORTANT:
Ensure you have proper gas pipe sizing when combining two burners together. Gas pipe
sized too small will cause improper operation from both burners.
Linear Burner Possible Configurations
MATCH THROW (MT) LIGHTING INSTRUCTIONS
ON
O
FF
Figure 4.
Key Valve Face
READ ALL WARNINGS AND SAFETY INFORMATION IN INSTALLATION MANUAL
BEFORE ATTEMPTING TO LIGHT FIRE PIT
CAUTION
: Ensure you have leak tested the fire pit before operating.
TURNING ON FIRE PIT
1. Insert key into shut-off valve and secure into square end (see Figs. 4 & 5).
2. Light a long match or butane lighter and hold it near the center of the burner.
3. Turn the key counter-clockwise in gas valve (until it stops) to allow gas to flow and
simultaneously apply the long burning match or Butane lighter as close to the end
burner as possible to light the fire pit. See Fig. 10.
4. Gas should ignite within 10 seconds or less. If fire pit does not light within 10 seconds
turn key clockwise to turn
OFF
the gas supply. Ensure there is not too much media on
top of the burner that might inhibit gas flow and try again in 5-minutes.
5. Repeat steps 1 - 4 with the second burner.
MATCH THROW (MT) INSTALLATION