![Skytec TEC6200 Operation Manual Download Page 3](http://html1.mh-extra.com/html/skytec/tec6200/tec6200_operation-manual_1291459003.webp)
OPERATION
1. Connect loudspeaker system (MINIMUM load 4 ohms) with sufficient handling capacity to the output terminals of the amplifier.
2. Connect output from mixer ( or any other suitable signal source) to the appropriate input sockets of the power amplifier.
NOTE. All inputs are UNBALANCED and connections for the XLR input are Pin 1 = Gnd, 2=+IN, 3= Gnd.
3. Connect the power cord to the mains.
4. Turn gain controls to minimum , switch on the amplifier and the red power LED will illuminate.
5. Adjust gain controls to required level. NOTE. If the audio input signal is too high, distortion will result and the CLIP indicator will light.
If the clip LED is lit permanently or flashes, the gain level should be reduced.
6. Protect LED. These power amplifiers feature a unique short circuit relay protection system. When the output is shorted the amplifier
will go into protect mode with the yellow LED illuminating. Switch OFF the unit and remove the short circuit. Switch ON the amplifier
and the output will be returned immediately.
For reliable and trouble free operation, please observe the following points:
• Ensure all input / output connections are correct and secure.
• The handling capacity of the loudspeakers is adequate for the output of the amplifier.
• Always site the amplifier in a well ventilated location
• Protect unit from severe shocks
3
TEC6200
TEC6300
TEC6500
TEC6950
Stereo output power RMS @ 0.1% THD
2 x 100W
2 x 150W
2 x 250W
2 x 500W
Maximum output power
2 x 200W
2 x 300W
2 x 500W
2 x 950W
Single channel driven 4
Ω
load
110W
165W
270W
540W
Load impedance minimum
4
Ω
4
Ω
4
Ω
4
Ω
Input connectors
RCA phono socket
RCA phono socket
1/4” (6.3mm) jack socket
Combination XLR/jack
(mono)
(1=Gnd, 2=+IN, 3=Gnd)
(mono)
Output connectors
1/4” (6.3mm) jack socket (mono)
Speakon (+1 /-1)
Input sensitivity
775mV
4dBBu (1.2V)
Input impedance
10K
10k
Frequency response
20Hz-20kHz ±3dB
THD +N
<0.05% @ 1kHz and rated power single channel
Signal to noise ratio
> 90dB
Cross-talk
> 50dB @ 1kHz
Protection
Protection against short circuit and DC on output
Indicators
Power on, CLIP-L, CLIP-R, PROTECT
Cooling
80mm fan
80mm fan
80mm fan
80mm fan
Mains power
230V, 50Hz
Power consumption
550VA
750VA
1100VA
2100VA
Fuses AC mains
T3.15A
T3.15A
T5A
T10A
DC
T3.15A
T3.15A
T5A
T12.5A
Dimensions (WxDxH)
482 x 88 x 330mm (2U)
482 x 88 x 335mm
Weight
10kg
10.3kg
10.5kg
14kg
Summary of Contents for TEC6200