background image

16

<3>Select

Right Fiber

, Press and hold the

button to move the fiber to the right

screenposition(As shown in Figure10.3.2).

Figure 10.6.1

Figure 10.6.2

Figure 10.5.1

Figure 10.5.2

<6>Select

X Window

,and then press and hold the

or

to make the center

line of the fiber in the X window overlap the horizontal auxiliary line in the X

window(As shown in Figure10.6.2).

Figure 10.4.1

Figure 10.4.2

<5>Select

Right fiber

and press and hold the

or

to align the left and right

fibers displayed in the Y window horizontally(As shown in Figure10.5.2 ).

<4>Select

Left fiber

and press and hold the

or

to align the left and right

fibers displayed in the X window horizontally(As shown in Figure10.4.2 ).

Figure 10.3.1

Figure 10.3.2

Summary of Contents for SS413F Series

Page 1: ...Shenzhen SKYSHL Technology Co Ltd Version V2020 08 ...

Page 2: ...Interface Description 5 5 Power supply 6 6 Cleaning operation before splicing 8 7 Regular maintenance 9 8 Basic Splicing Procedures 11 9 ARC Calibration 14 10 Manually adjust the fiber position 15 11 Cutting Length of Optical Fiber 18 12 Common troubleshooting 18 Appendix A Warranty period and conditions 20 ...

Page 3: ...ess splice loss light weight portable applicable to backbone network metropolitan network and FTTH project In order to complete accurately the splice operation please read carefully this user s manual SS413F Video youtu be llfhWtie48c 2 Product specifications 1 Applicable optical fibers SM G 652 G 657 MM G 651 DS G 653 NZDS G 655 and user defined optical fibers Splice loss 0 02dB SM 0 01dB MM 0 04...

Page 4: ...Heater mode 40 groups user mode 11 groups factory mode Connection storage Built in memory is capable to save latest 10000 splices Store 100 groups of splice images X Y fiber splicing images Electrode life 5500 times times of arc Lithium battery Continuous splicing heating more than 350 times typical environment Power saving function In Power Save Mode Under typical circumstances can save 15 batter...

Page 5: ...Name of main components of fusion splicer Left fiber clamp Heating groove Heater right press plate Heater transparent window cover Heater left press plate 3 2 Descriptions of the keypad of fusion splicer Right fiber clamp V groove Electrode 3 ...

Page 6: ...oving cursor Rightward movement of fiber Invalid Increasing the amount of parameters moving cursor Invalid Return to readiness screen Return to readiness screen Return to higher level menu screen Invalid Invalid Invalid Confirming option function Parameter modification Enter splice mode menu Open the function to move motor by buttons at pause Invalid Enter lower level menu operation screen Start s...

Page 7: ...g up at current Bottom of screen Indicating Keypad operation on current screen 4 3 Heater mode 4 4 Arc Calibration 4 2 Splice options 4 2 1 Operation Options Top right corner of the screen Indicating the present power supply mode of power adapter 4 1 Standby Interface of fusion splicer Level 1 Menu 5 ...

Page 8: ...d to install lithium batteries Adapter AC input Only AC power cord attached to the adapter is used and the input voltage is AC100 240V 50 60HZ The grounding terminal of AC power line input must be grounded effectively Adapter DC output Use only the DC power cord attached to the adapter Output voltage DC13 5V 4 8A Insert DC power cord into the POWER INPUT port at the bottom of splicer The splicer s...

Page 9: ...s off the charging time is up to 3hours 30minutes 40minutes and the battery is surplus The amount of capacity determines the length of charging time Battery maintenance Please store lithium batteries in a cool dry and safe environment Do not place the lithium battery near high temperature flammable and explosive gases or liquids If the lithium battery needs to be stored for a long time more than o...

Page 10: ...sion splicer has low voltage alarm function When the lithium battery group power is below a certain value the fusion splicer screen will show low battery warning window as shown below At this point the user should promptly use the power adapter or charge the lithium battery or hold down button to turn off the fusion splicer Otherwise it will shut down automatically after about 30 seconds 6 Cleanin...

Page 11: ...pecific lens paper into a stick fold and tear out then clean the mirror objective lens surface with the rough edge of the stick 7 Regular maintenance Cleaning objective lens SS413F has no mirror only camera In routine maintenance the ear syringe may be used for blowing off the dust from the surface of the mirror and the objective lens of the fusion splicer When cleaning be careful not to bump into...

Page 12: ...nt of electrode Electrodes will be worn out after long term use plus silicic oxide accumulates on the tip it also requires regular cleaning It is recommend to replace the electrode when the electrode rod exceeds its service life If the machine continues in service without changing the electrode it will increase splice loss and reduce the strength after fusion splicing Use of lithium batteries Lith...

Page 13: ...een observation of optical fiber welding 11 7 Place optical fibers in V groove of the SS413F 8 Basic Fusion Procedures Youtube Video https youtu be A6uZtgps8Ok The end of the optical fiber is placed between the V groove edge and the center of the electrode Electrode center V groove edge Auto SM fusion mode is Recommended for SM G 652 G 657 Standard 60mm heater mode is recommended for the length of...

Page 14: ... fiber is connected with 250 μm bare fiber Open the wind cover and wait for the automatic reset of the fusion splicer until the machine is at readiness status Put respectively the prepared fibers into The bottom of left and right V grooves of the fusion splicer When the windproof cover is closed the splicer will automatically complete fusion between the following different kinds of optical fibers ...

Page 15: ...ng The clamp must meet the industry standard FTTH hot melt quick connector Need a SOC fiber fixing clip optional the leather cable is connected with the leather cable 250μm bare fiber is connected with the leather cable ...

Page 16: ... may lead to increased splicing loss of the l splicer Arc calibration can effectively reduce the splicing loss It is recommended to do an ARC calibration before the first use after getting the machine 1 Select Arc Calibration from the main menu page 3 Closing the cover will automatically start the arc calibration 4 If Step1 Arc Calibration Not Finished or Step2 Arc Calibration Not Finished is disp...

Page 17: ...to adjust the position of the fiber Due to the dust on the construction site the initial position of the motor changed When the fiber is welded the motor stroke cannot reach the alignment position which leads to the wrong position of the fiber and welding cannot be performed After cleaning the dust in the V groove the fusion splicer still can not be welded so we need to manually adjust the positio...

Page 18: ...f the fiber in the X window overlap the horizontal auxiliary line in the X window As shown in Figure10 6 2 Figure 10 4 1 Figure 10 4 2 5 Select Right fiber and press and hold the or to align the left and right fibers displayed in the Y window horizontally As shown in Figure10 5 2 4 Select Left fiber and press and hold the or to align the left and right fibers displayed in the X window horizontally...

Page 19: ...iliary line As shown in Figure10 8 2 Figure 10 7 1 Figure 10 7 2 7 Select Y Window and then press and hold the or to make the center line of the fiber in the Y window overlap the horizontal auxiliary line in the Y window As shown in Figure10 7 2 Figure 10 9 1 Figure 10 9 2 9 Select Y Window and then press the or key to overlap the center of the gap between the left fiber and the right fiber in Y W...

Page 20: ...s too low 1 Clean the fiber 2 Cut the end face of the fiber again and make sure the end face of the fiber is flat 3 Replace with new electrodes 4 Stable electrode Maintenance Electrode Stabilize Electrode Unfused 1 Too high pre arc intensity 2 Propulsion speed is too slow 3 Advance blocked 1 Do arc calibration 2 Stable electrode Maintenance Electrode Stabilize Electrode 3 Clean V groove Variable d...

Page 21: ...Gk The end of the fiber has burrs Fiber end face protrusion Blurred fiber image 1 Camera is dirty 1 Clean the camera Defect Reason Measures Cannot start the machine 1 The battery is too low 2 No battery installed 3 The adapter has no power 1 Replace the battery or charge the machine 2 Install the batteries in the machine 3 Connect the power supply to the adapter Fiber is not automatically spliced ...

Page 22: ...label on the enclosure of the fusion splicer and disassemble and repair the machine without authorization The user tears up warranty void after tearing up the label label on the enclosure of the lithium battery Consumable parts such as arc electrode cutter blade fusion splicer carrying case etc Exemption clauses For the use of non original battery battery charger power adapter and so on not provid...

Page 23: ...oblems occur How is the current situation The character and image information of optical fiber on the display when the machine fails 4 List of parts in the machine Symbols and Sign High voltage warning sign there is high voltage please do not touch it High temperature warning sign high temperature exists please do not touch it The company s product performance and properties are improving and subj...

Page 24: ......

Reviews: