background image

Terminal Voltage Control (TVC)

The charger allows user to set the charge/discharge end voltage.

Battery Meter

The user can check Lithium battery's total voltage, the highest voltage, the lowest voltage and each 
cell's voltage; and can check Nickel and Pb battery's total voltage.

Re-Peak Mode of NiMH/NiCd Battery

In re-peak charge mode, the charger can peak charge the battery once, twice or three times in a row 
automatically. This is good for making certain the battery is fully charged, and for checking how well 
the battery receives fast charges.

Delta-peak Sensitivity for NiMH/NiCd

Delta-peak  sensitivity  for  NiMH/NiCd  battery:  The  automatic  charge  termination  program  based  on 
the principle of the delta-peak voltage detection. When the battery's voltage exceeds the threshold, 
the process will be terminated automatically.

Automatic Charging Current Limit

You can set up the upper limit of the charging current when charging your NiMH or NiCd battery, it is 
useful for the NiMH battery of low impedance and capacity in the 'AUTO' charging mode.

Capacity Limit

The charging capacity is always calculated as the charging current multiplied by time. If the charging 
capacity exceeds the limit, the process will be terminated automatically when you set the maximum 
value.

Temperature Threshold*

The  battery's  internal  chemical  reaction  will  cause  the  temperature  of  the  battery  to  rise.  If  the 
temperature limit is reached, the process will be terminated.

Processing Time Limit

You can also limit the maximum process time to avoid any possible defect

PC Control Software “Charge Master”

There is a mini USB port in the charger which can be used to connect it to the PC. You need optional 
USB  cable  (USB A  Male  to  Mini  B  Male)  which  is  not  included  in  the  package.  The  free  “Charge 
Master”  software  gives  you  unparalleled  ability  to  operate  the  charger  through  your  computer.  You 
can monitor pack voltage, cell voltage and other data during the charging, view charge date in real-
time graphs. And you can initiate, control charging and update firmware from “Charge Master”.

When your charger is connected to computer, the “Charger Master” takes over the control of charger.  
You can control and operate the charger via the “Charger Master” only.

Multi-Language and Four Color Theme Optional

There are two languages and four kinds of color theme stored in the charger and users could select 
the display language and color theme as basing on personal preference.

Inner resistance of battery pack

Measure Inner resistance of battery pack inclusively all connectors and leads. 

MAIN

 

FEATURES

WARNING  AND  SAFETY NOTES

These warnings and safety notes are particularly important. Please 
follow  the  instructions  for  maximum  safety;  otherwise  the  charger 
and the battery can be damaged or at worst it can cause a fire.

The

 

allowable DC input

 

voltage is 11-18V DC

.

The

 

allowable

 

AC input voltage is 100-240V AC

.

Never  leave  the  charger  unattended  when  it  is  connected  to  its  power  supply.  If  any 
malfunction  is  found,  TERMINATE  THE  PROCESS AT  ONCE  and  refer  to  the  operation 
manual.
Keep  the  charger  well  away  from  dust,  damp,  rain,  heat,  direct  sunshine  and  vibration. 
Never drop it.

This  charger  and  the  battery  should  be  put  on  a  heat-resistant,  non-flammable  and  non-
conductive  surface.  Never  place  them  on  a  car  seat,  carpet  or  similar  surface.  Keep  all 
flammable volatile materials away from the operating area.

Make  sure  you  know  the  specifications  of  the  battery  to  be  charged  or  discharged  to 
ensure it meets the requirements of this charger. If the program is set up incorrectly, the 
battery  and  charger  may  be  damaged.  Fire  or  explosion  can  occur  due  to  overcharging. 
This warranty is not valid for any damage or subsequent damage arising as a result of a 
misuse or failure to observe the procedures outlined in this manual. 

To avoid short circuiting between the charge lead, always connect the charge cable to the 
charger first, then connect the battery. Reverse the sequence when disconnecting.

Never

 

attempt to charge or discharge the following

 

types of batteries:

A battery fitted with an integral charge circuit or a protection circuit

A battery pack which consists of different types of cells (including different manufacturers)
A battery that is already fully charged or just slightly discharged

Non-rechargeable batteries (pose an explosion hazard)
A faulty or damaged battery

Batteries installed in a device or which are electrically linked to other components

Batteries  that  are  not  expressly  stated  by  the  manufacturer  to  be  suitable  for  the 
currents the charger delivers during the charge process

Please

 

bear

 

in

 

mind

 

the

 

following

 

points

 

before

 

commencing

  

charging

:

Did you select the appropriate program suitable for the type of battery you are charging?
Did you set up adequate current for charging or discharging?
Have you checked the battery voltage? Lithium battery packs can be wired in parallel and 
in series, i.e. a 2-cell pack can be 3.7V (in parallel) or 7.4V (in series).
Have  you  checked  that  all  connections  are  firm  and  secure?  Make  sure  there  are  no 
intermittent contacts at any point in the circuit.

Be very careful to choose the correct voltage for different types of battery otherwise you may cause 
damage to the batteries.  Incorrect settings could cause the cells to fire or explode.

Standard Battery Parameters

LiPo

LiIon

LiFe

NiCd

MiMH

Pb

3.7V/cell

3.6V/cell

3.3V/cell

1.2V/cell

1.2V/cell

2.0V/cell

4.2V/cell

4.1V/cell

3.6V/cell

1.5V/cell

1.5V/cell

2.46V/cell

3.7V/cell

3.8V/cell

3.3V/cell

n/a

n/a

n/a

3.0-3.3V/cell

2.9-3.2V/cell

2.6-2.9V/cell

0.1-1.1V/cell

0.1-1.1V/cell

1.8V/cell

Nominal Voltage
Max Charge Voltage

Storage Voltage
Min. Discharge Voltage

T

6755

T

6755

05

04

WARNING  AND  SAFETY NOTES

You can download 

Charge Master

 software from our website  www.skyrc.com

Users can control and monitor the charge through computer when  

Charge Master

 software is installed.

This function is available by connecting optional temper ture probe which is not included in the package.

a

Fire Hazard!

WARNING

Summary of Contents for T6755

Page 1: ...in China 2013 All specifications and figures are subject to change without notice Manufactured by SKYRC TECHNOLOGY CO LTD www skyrc com 7504 0339 01 55 55 7 7 3 2 3 2 TOUCH SENSITIVE TOUCH SENSITIVE...

Page 2: ...ol charge discharge station with battery management suitable for use with all current battery types With integral equalizer for six cell Lithium Polymer LiPo Lithium Ferrum LiFe and Lithium Ion LiIon...

Page 3: ...t need to worry about any damage caused by improper input voltage Internal Independent Lithium Battery Balancer SKYRC T6755 Charger employs an individual cell voltage balancer It isn t necessary to co...

Page 4: ...arger unattended when it is connected to its power supply If any malfunction is found TERMINATE THE PROCESS AT ONCE and refer to the operation manual Keep the charger well away from dust damp rain hea...

Page 5: ...plosion Lithium batteries are recommended to charge in series Discharging The main purpose of discharging is to clean the residual capacity of the battery or to reduce the battery voltage to a defined...

Page 6: ...sequence when disconnecting the pack 3 Balance Socket Using terminal clip attaching to car battery WARNING Failure to connect as shown in this diagram will damage this charger The balance wire attache...

Page 7: ...alancing to stimulate the battery s activity The user can check Nickel battery s total voltage LiPo Lilon LiFe CHARGE DISCHARGE STORAGE FAST CHG BAL CHARGE VOLT METER CHARGE AUTO CHG DISCHARGE CHARGE...

Page 8: ...erate the charger through the computer You can monitor pack voltage cell voltage and other data during the charging process view charging data in real time graphs And you can initiate control charging...

Page 9: ...program Please touch and to get the right battery cells count and desired charge discharge current NOTE 2 CALL OUT The basic settings of the profiles are displayed and you could touch the settings ba...

Page 10: ...e terminated ENTER CAPACITY CUT OFF 5000 mAh 120 Min TEMP CUT OFF 45 C 113 F NEXT HOME SAFETY PROTECTION SAFETY TIME OFF Please touch and screen to make the functions ON or OFF And touch and to get th...

Page 11: ...ECTION ERROR BATTERY WAS FULL It incorporates a variety of functions for the systems to verify processes and the state of the electronics In case of an error the screen will display the cause of error...

Page 12: ...EN60335 2 29 FCC FCC Part 15 Limits Limitation of voltage charges voltage fluctuations and flicker in public low voltage supply systems for equipment with rated current 16A per phase and not subject t...