SPECIAL  FEATURES

05

6X80 Plus

6X80 Plus

Data Store/Load

The  charger  can  store  up  to  10  different  charge/discharge  profiles  for 
your convenience. You can keep the data pertaining to program setting 
of the battery of continuous charging or discharging. Users can call out 
these data at any time without any special program setting. 

Terminal Voltage Control(TVC)

The charger allows user to change the end voltage.

Lipo Battery Meter

The  user  can  check  battery's  total  voltage,  the  highest  voltage,  the 
lowest voltage and each cell's voltage.

Motor RPM Tester

Users connect the sensor motor and charger with sensor wire, set the 
pulse width and test the RPM of the motor.

Servo Tester

Connect  the  servo  and  the  charger  with  wire,  change  the  pulse  width 
value and check whether the servo works or not.

Re-Peak Mode of NiMH/NiCd Battery

In  re-peak  charge  mode,  the  charger  can  peak  charge  the  battery 
once,  twice  or  three  times  in  a  row  automatically.  This  is  good  for 
making  certain  the  battery  is  fully  charged,  and  for  checking  how  well 
the battery receives fast charges. 

Delta-peak Sensitivity for NiMH/NiCd

Delta-peak  sensitivity  for  NiMH/NiCd  battery:  The  automatic  charge 
termination  program  based  on  the  principle  of  the  Delta-peak  voltage 
detection.  When  the  battery's  voltage  exceeds  the  threshold,  the 
process will be terminated automatically. 

SPECIAL  FEATURES

Automatic Charging Current Limit

You  can  set  up  the  upper  limit  of  the  charging  current  when  charging 
your  NiMH  or  NiCd  battery,  it  is  useful  for  the  NiMH  battery  of    low 
impedance and capacity in the 'AUTO' charging mode.

Capacity Limit

The  charging  capacity  is  always  calculated  as  the  charging  current 
multiplied  by  time.  If  the  charging  capacity  exceeds  the  limit,  the 
process  will  be  terminated  automatically  when  you  set  the  maximum 
value.

Temperature Threshold*

The battery's  internal chemical reaction will cause the temperature of 
the battery to rise. If the temperature limit is reached, the process will 
be terminated.

Processing Time Limit: 

You  can  also  limit  the  maximum    process  time  to  avoid    any  possible 
defect.

PC Control Software “Charge Master”

The  free  “Charge  Master”  software  gives  you  unparalleled  ability  to 
operate  the  charger  through  the  computer.  You  can  monitor  pack 
voltage,  cell  voltage  and  other  data  during  the  charging,  view  charge 
date  in  real-time  graphs.  And  you  can  initiate,  control  charging  and 
update firmware from “Charge Master”.

This  function  is  available  by  connecting  optional  temperature  probe,  which  is 
not included in the package.

*

Summary of Contents for 6x80Plus

Page 1: ...Meter Motor RPM Tester Servo Tester Professional Balance Charger Discharger Lithium Battery Meter Motor RPM Tester Servo Tester Version 1 0 Printed in China 2012 All specifications and figures are subject to change without notice Manufactured by SKYRC TECHNOLOGY CO LTD www skyrc com 7504 0301 01 ...

Page 2: ...fan speed is controlled by internal temperature sensor It also adds lithium Batt Meter Motor RPM Tester and Servo Tester functions It is convenient for user to get some useful information with this charger It can be dangerous to mis handle batteries and battery chargers as there is always a risk of batteries catching fire and exploding Please BE SURE to read these INSTRUCTIONS WARNING and SAFETY N...

Page 3: ...on to achieve the maximum safety and minimize the trouble All the settings can be configured by users Internal Independent Lithium Battery Balancer SKYRC 6x80 Plus employs an individual cell voltage balancer It isn t necessary to connect an external balancer for balance charging Balancing Individual Cells Battery Discharging During the process of discharging SKYRC 6x80 Plus can monitor and balance...

Page 4: ...ic charge termination program based on the principle of the Delta peak voltage detection When the battery s voltage exceeds the threshold the process will be terminated automatically SPECIAL FEATURES Automatic Charging Current Limit You can set up the upper limit of the charging current when charging your NiMH or NiCd battery it is useful for the NiMH battery of low impedance and capacity in the A...

Page 5: ...es A battery fitted with an integral charge circuit or a protection circuit A battery pack which consists of different types of cells including different manufacturers A battery that is already fully charged or just slightly discharged Non rechargeable batteries pose an explosion hazard A faulty or damaged battery WARNING AND SAFETY NOTES Batteries installed in a device or which are electrically l...

Page 6: ...connection the battery s capacity is calculated by multiplying single the battery s capacity by the number of cells bearing in mind that total voltage stays the same If the voltage is imbalanced it may cause a fire or explosion Lithium batteries are recommended to charge in series WARNING AND SAFETY NOTES WARNING AND SAFETY NOTES Discharging The main purpose of discharging is to clean the residual...

Page 7: ...id short circuits between the banana plugs always connect the charge leads to the charger first and only then to the battery Reverse the sequence when disconnecting the pack Using terminal clip attaching to car battery Balance socket The balance wire attached to the battery must be connected to the charger with the black wire aligned with the negative marking Take care to maintain correct polarity...

Page 8: ...0A NiMH DISCHARGE 0 1A CUT 1 0V NiMH CYCLE CHG DCHG 1 PROGRAM SELECT LiPo BATT LiPo BALANCE 2 0A 7 4V 2S LiPo CHARGE 2 0A 7 4V 2S LiPo FAST CHG 2 0A 7 4V 2S LiPo STORAGE 2 0A 7 4V 2S LiPo DISCHARGE 2 0A 7 4V 2S ENTER START PROGRAM SELECT Lilo BATT Lilo BALANCE 2 0A 7 2V 2S Lilo CHARGE 2 0A 7 2V 2S Lilo FAST CHG 2 0A 7 2V 2S Lilo STORAGE 2 0A 7 2V 2S Lilo DISCHARGE 2 0A 7 2V 2S ENTER START PROGRAM ...

Page 9: ...on PROGRAM These programs are only suitable for charging and discharging lithium batteries with a nominal voltage of 3 7V 3 6V and 3 3V per cell These batteries need to adopt different charge technique which is termed as constant voltage CV and constant current CC method The charge current varies according to the battery capacity and performance The final voltage of charge process is also very imp...

Page 10: ... Charged capacity Number of cells Charging time Charging current Battery voltage S is the number of cells set by you at the previous screen If both numbers are identical you can start charging process If not press button to go back to previous screen to recheck the number of cells of the battery pack before going ahead This screen shows the real time status during charge process Press button once ...

Page 11: ...bers are identical you can start charging process If not press Mode Stop button to go back to SELECT SELECT Mode Stop Press Dial Press Dial 18 19 6X80 Plus 6X80 Plus LITHIUM BATTERY LiPo LiFe LiIon PROGRAM Number of cells Elapsed time Charge or discharge current Supplied capacity Current voltage battery This screen shows the real time status charging Press Mode Stop button once to stop the charge ...

Page 12: ...Press START ENTER dial to store the value SELECT Mode Stop Battery type 3 seconds Mode Stop Press Dial Press Dial NiMH 2 0A 9 52V AUT 000 13 00000 CHARGING BATTERY IN RE PEAK CHARGE MODE NIMH NICD Re peak Charge Mode NiMH and NiCd batteries only In re peak charge mode the charger can peak charge the battery once twice or three times in a row automatically This is good for confirming the battery is...

Page 13: ...e from 2 to 20V Pb batteries are totally different from NiMH or NiCd batteries They can only deliver relatively lower current comparing to their capacity and similar restrictions definitely apply to charge So the optimal charge current will be 1 10 of the capacity Pb batteries must not be charged rapidly Always follow the instruction supplied by the battery manufacturer CHARGING OF PB BATTERY Batt...

Page 14: ...CT SELECT SELECT SELECT Press Dial Battery type Elapsed time Discharge current Battery voltage Discharged capacity The screen displays the current state of discharge You can alter the discharge current by pressing Start Enter dial during the process Once you find the desired current value by rotating the dial store it by repressing the dial To stop discharging press Mode Stop button once The audib...

Page 15: ...ELECT SELECT SELECT SELECT SELECT SELECT BATTERY MEMORY SET Press Dial Set the cut off temperature which can be adjusted 20 C 68 F 80 C 176 F 26 27 6X80 Plus 6X80 Plus LITHIUM BATTERY METER PROGRAM SELECT Li BATT METER Press the Start Enter dial to enter the Lithium Battery Meter program 4 19 4 15 4 18V 0 00 0 00 0 00V The screen indicate each cell s voltage MAIN 12 52V H4 190V L4 160V The screen ...

Page 16: ... Switch on the ESC The left side of the first line shows the pulse width and the second line shows the RPM of the motor corresponding to different pulse width The value of pulse width can be changed by rotating the Start Enter dial 1 2 3 4 5 6 7 PROGRAM SELECT MOTOR RPM TESTER SELECT PULSE WIDTH 1500 RPM 00000 SELECT This diagram shows the correct connect way to test motor RPM 28 29 6X80 Plus 6X80...

Page 17: ...o allow a full charge of the battery Safe timer Calculation When charging NiMH or NiCd batteries divide the capacity by current then divide the result SELECT SELECT SELECT SELECT SELECT SELECT 30 31 6X80 Plus 6X80 Plus Capacity Cut Off ON 5000mAH Key Beep ON Buzzer ON Capacity Current Safety Time 2000mAh 2 0A 2000 2 0 1000 11 9 84 minutes 3300mAh 3 0A 3300 3 0 1100 11 9 92 minutes 1000mAh 1 2A 100...

Page 18: ...0 Plus It incorporates a variety of functions for the systems to verify processes and the state of the electronics In case of an error the screen will display the cause of error and emit an audible sound Incorrect polarity connected The battery is interrupted CONNECT ERROR CHECK MAIN PORT The Battery connection is wrong The cell number is wrong CELL NUMBER INCORRECT Voltage of one cell in the batt...

Page 19: ... 20V 525g 135x112x60 9mm Discharge current power 1 2 3 4 THE SET CONTAINS 1 SKYRC 6x80 Plus Charger 2 XH Adaptor 3 Power Cord 4 18AWG Wire Charging Cable 34 35 6X80 Plus 6X80 Plus TP FP Adaptor Temp Sensor Cable EH Adaptor XH Adaptor Dean charging cable HP PQ Adaptor Tamiya charging cable TRAXXAS charging cable Glow charging cable Crocodile clip charging cable Futaba RX charging cable RECOMMENDED ...

Page 20: ... maintaining the device For this reason we are obliged to deny all liability for loss damage or costs which are incurred due to the incompetent or incorrect use and operation of our products or which are connected with such operation in any way Unless otherwise prescribed by law our obligation to pay compensation regardless of the legal argument employed is limited to the invoice value of those SK...