4.5  code with the wireless panel 

Enter the wireless system setting status. chose the panel remote code mode, 
trigger the arm or disarm key in the keypad, then the panel will get the wireless 
signal , then press the save key in the panel. ( please  refer to remote code in panel manual)

    Our wireless products have stable performance. But, it will be limited in some range for
    their low transmitting ability. As follow
    1.the receiver will be blocked or it is out of the scape of the frequency
    2.usally test the collision and take protect methods
    3.when the power is not stable or the senors is power short, it will be signal fault.

5

clean and  protect

   

when it is dirty, please clean it by sponge using mixed cleaner and water. Note: 
please do not make much water leak into the shell to damage the circuit board

6

 product work shortage

-2-

4.3 bypass zone

 it is available when  in the dual-way mode

ENTER

987699

13

OK

enter the zone number by two digits

OK

1

OK

will sound "didi...." , It is successful.

4.4 Dual-way communication mode

( it is our factory default setting)

ENTER

987699

15

OK

1

OK

                      

0

OK

1

OK

The working mode of the keypad

one way

used as a re

mote controller

dual-way communication

 Set the door sensor enable or diable( the function has not used yet
 Set the tamper is enable or disable

ENTER

987699

15

OK

3

OK

                      

0

OK

1

OK

 Disable

Enable

 NOTE

disarm

key can be used as 

inquiry 

key when it is at the status of 

                 dual-way communication

press once 

will display the panel status

                 ( as many zone alarm,can press

disarm

to enquiry

.

Note

set the zone attribute to be 1, it is bypass;set to be 0, cancer the bypass.

4.2 set the password:(the passwords for user 2~ user 10 are empty for our factory default setting

Change the user password

 ENTER 

987699

OK

                

OK

enter new user 

                                                   password

OK

Change administrator password

ENTER

987699

12

OK

enter 6 digits new 

                                                  administrator password

OK

2

11

Finish setting, press 

BACK

to back the program status, or the system will back 

after 30S itself.