background image

The sensor  must be programmed to the Household Alert

®

  Long Range

Receiver before they can communication. You may program the sensors

to one of the 4 zones. Follow the instructions below:

1. Plug in an AC adapter to the receiver.

2. The green LED will be on indicating it is turned on.

3. Open the back cover and there is a learn button. Press and hold this

learn button for 5 seconds, until both green LED and zone 1 red LED

 You may now release the learn button.

4. If you would like to program the sensor to zone 1, activate the

sensor while the zone 1 red LED is 

 Press the SET button

on the back of the sensor to activate it.

5. If you would like to program the sensor to other zones, press the

learn button again, until the red LED 

 at the zone you want to

program the sensor to, then activate the sensor.

6. Once the sensor is programmed, the green LED will be steadily on

and none of the red zone LEDs will be on.

Note: Each zone can program up to 4 sensors. If you try to program a

 sensor into a zone, the 

 programmed sensor will be erased.

Erasing a sensor

 

You  cannot  erase  a 

  sensor. You  must  erase  all  sensors  from

the receiver, then program the ones you would like to keep. To erase

all the sensors from the receiver:

1. Remove the adapter from the receiver.

2. Open the back cover, press and hold the learn button. Do not

    release the learn button until step 4.

3. While holding onto the learn button, plug in the adapter to the receiver.

4. You may  release the learn button when the LEDs on the receiver are on.

5. You have erased all sensors from the receiver.

1. INTRODUCTION

Deluxe Home Monitoring Kit

 

 

Model

 

HA-400

In this package, you should find two Window/Door Sensors, a Motion Sensor, 

a Household Alert   Long Range Receiver, an adapter, ball-head joint, screws 

and other mounting accessories.

Please follow the instructions below to setup your motion sensor and

the  receiver.

Adapter

2  pcs  3 x 18 screws

(Included)

 Indoor/Outdoor

Motion Sensor

Ball-head joint

Plug in the adapter to the receiver

Insert 9V alkaline battery (option) to the sensor

2.

 

PROGRAMMING  MOTION SENSOR

 

3. MOTION SENSOR INSTALLATION

A ball-head joint is necessary to mount the sensor at a desire location.

A height of 7 ft is recommended, depending on your application. Once a

location is selected, mount the ball-head joint to this location by screws

provided. Once the ball-head joint is mounted to the wall, slide the back

of the sensor into the ball-head joint. The mounting angle can be

adjusted. Please refer to “Walk Test” to determine the best mounting

angle.

After mounting the sensor at the desired location, it is

important to perform a walk test in order to determine

 if the sensor is detecting the things you want to detect.

In order to control how far the sensor can “see”, this can be done by

adjusting the angle of the sensor.  To reduce the detection range, simply

move  the  sensor  downward. To  increase  the  range,  move  the  sensor

up to around 12 degrees.  This will give the maximum range.  However,
this may not be desired if the sensor is placed outdoors, since

 

a false

trigger may occur if the sensor is set to detect motion in a distance.

 

You should walk in the area that you would like the sensor to monitor.

Place the slide switch on the side of the receiver to “Alert” position. The

receiver will beep if the sensor detects your movement. If the receiver

does not respond, adjust the mounting angle accordingly. After motion is

detected once, the sensor will not be triggered unless no motion is

detected  for  20  seconds.  Therefore,  wait  for  at  least  20  seconds  during

walk  testing  between  2  activations.

Perform walk test in the undesired area to ensure movement cannot be

detected.

Household Alert

®

Long Range Receiver

SET Button

7 ft

Tips:  The  sensor  should  not  face  towards  direct  sunlight,  placing  near

heat or cold producing  devices (i.e. A/C or furnance  vents, fans, ovens,

heaters  etc.)  that  may  cause false triggers.

Move the sensor downward to

reduce the range.

Move the sensor up to around

12 º to give maximum range.

The sensitivity of the motion sensor is adjustable. Change the setting by

placing the connector on either the ”High” (connector position “1”) or

“Low” (connector position “2”) position. When the sensitivity is set to

“Low”, more movement is required to trigger the sensor. It is recom-

mended to set the sensitivity to “Low” and perform a “Walk Test”. If the

walk test result is 

 the sensitivity does not require to be

adjusted further. If the walk  test

result shows the sensitivity is too

low, then you can change the

sensitivity setting to “High”. Please

perform the walk test after changing

the  sensitivity  setting.

1 - High             2 - Low

 Learn Button

Mounting

Accessories

2 x Magnet Sensor

The Deluxe Home Monitoring Kit is designed to monitor movement or any 

door and window around your house. The  motion sensor can be placed either 

indoor or outdoor. Once motion is detected or a window/door is opened, the

receiver will flash along with alert beeping or alarm.

®

SENSOR SENSITIVITY

WALK TEST

MOUNTING

Page 1 of 3

Reviews: