Skylab VG05 User Manual Download Page 8

 

Skylab M&C Technology Co., Ltd 

 

 

                 

 

 

  8 / 30

                                                                                                                                     

VG05-DA-001,A/0 

VG05-DA-001,A/

3. Hardware Guide 

3.1 VG05 Power on 

VG05 will power on as soon as any one of its 2 batteries is correctly installed. By default , 2 

CR14250 battery will be pre-

installed before it arrives at customers’ hand.   

If you need to change its batteries, please follow the instruction below. 

a.  Remove 4 screws with a Phillips screwdriver 

 

 

 

Summary of Contents for VG05

Page 1: ...User Manual Document Information Title VG05 Bluetooth Beacon User Manual Document type Datasheet Document number SL 19040126 Revision and date V1 01 10 June 2019 Disclosure restriction Public Revisio...

Page 2: ...third parties of this document or any part thereof without the express permission of SKYLAB is strictly prohibited The information contained herein is provided as is and SKYLAB assumes no liability fo...

Page 3: ...05 Power on 8 3 2 VG05 Installation instructions 9 4 Software Application Guide 12 4 1 Download APP 12 4 2 Scan Bluetooth 4 2 Beacon 12 4 3 Connect Bluetooth 4 2 Beacon 13 4 4 Configuration Introducti...

Page 4: ...Skylab M C Technology Co Ltd 4 30 VG05 DA 001 A 0 VG05 DA 001 A 0 List Device Name Device No Number Remark Bluetooth 4 2 Beacon VG05 1 PCS Battery CR14250 2 PCS Inside VG05...

Page 5: ...ing information can be read by Skylab_xbeacon APP which is designed by Skylab R D Team 1 1 VG05 Internal Module Introduction VG05 is based on Nordic Bluetooth 4 2 chip It is powered by 2 CR14250 batte...

Page 6: ...ss Features Wireless Standards Bluetooth 4 2 Frequency Range 2400MHz 2483 5MHz Data Rates 250kbps 1Mbps 2Mbps Modulation Technique GFSK Modulation Wireless Security AES HW Encryption Transmit Power Tx...

Page 7: ...ery life days 4 70 100 8 70984 276 400 2 23146 1076 500 1 799568 1334 1000 0 935784 2565 0 50 100 5 82984 412 400 1 51146 1588 500 1 223568 1961 1000 0 647784 3705 4 35 100 4 38984 547 400 1 15146 208...

Page 8: ...ower on VG05 will power on as soon as any one of its 2 batteries is correctly installed By default 2 CR14250 battery will be pre installed before it arrives at customers hand If you need to change its...

Page 9: ...l of the VG05 follow the Battery polarity on the bottom of the battery cell and replace its 2 CR14250 Li Batteries c Close the bottom shell with its rubber needling aligned to the sink around the side...

Page 10: ...Skylab M C Technology Co Ltd 10 30 VG05 DA 001 A 0 VG05 DA 001 A 0 a Clean up VG05 bottom side screw side b Tear off 3M round tape from the oil paper and sticky it to the bottom side...

Page 11: ...make VG05 bottom side and 3M tape fully bonded d Remove the protective oilpaper on the other side of the 3M tape and install VG05 to target installation location if there is dust or grease stain in th...

Page 12: ...uide 4 1 Download APP Skylab_xbeacon hasn t been put into the market yet Please contact our salesman for this APP 4 2 Scan Bluetooth 4 2 Beacon Open the APP if cell phone ask for permission to open bl...

Page 13: ...o Ltd 13 30 VG05 DA 001 A 0 VG05 DA 001 A 0 4 3 Connect Bluetooth 4 2 Beacon Click the Bluetooth 4 2 Beacon to be connected enter the password within 30 seconds in order to obtain operating privileges...

Page 14: ...cted UUID 128 bit identifier according to ISO IEC11578 1996 standard 32 hexadecimal digits Major set 16 bit identifier 0 65535 Minor set 16 bit identifier 0 65535 Measured Power Signal strength at 1 m...

Page 15: ...nfiguration will take effect after the bluetooth connection is disconnected 4 5 Modify Bluetooth 4 2 Beacon Name Click the Device Name the following UI will be opened Then enter a length of less than...

Page 16: ...30 VG05 DA 001 A 0 VG05 DA 001 A 0 4 6 Modify UUID Click the UUID the following UI will be opened Then and then enter a 32 byte string of sixteen as the UUID of VG05 in the following Enter an UUID bo...

Page 17: ...logy Co Ltd 17 30 VG05 DA 001 A 0 VG05 DA 001 A 0 4 7 Modify User service data Click the User service data the following interface will be opened Then enter a Hexadecimal string of 24 word Then click...

Page 18: ...Co Ltd 18 30 VG05 DA 001 A 0 VG05 DA 001 A 0 4 8 Modify Major Minor Click the Major Minor the following UI will be opened Then set a value between 0 65535 as the Major Minor value of the device Then c...

Page 19: ...9 Modify Measured Power Click the Measured Power the following UI will be opened Then select a measured power range from 100dBm to 30dBm The default is 61dBm Then click confirm to modify Measured Pow...

Page 20: ...DA 001 A 0 4 10 Modify Transmitting Power Click the Transmitting Power the following UI will be opened Then set a transmitting power which can be set to 30dBm 20dBm 16dBm 12dBm 8dBm 4dBm 0dBm 4dBm and...

Page 21: ...1 Modify Advertise Interval Click the Advertise Interval the following UI will be opened Then set a advertise interval Broadcasting interval can be set to 100ms 200ms 300ms 400ms 500ms 600ms 700ms 800...

Page 22: ...VG05 DA 001 A 0 VG05 DA 001 A 0 4 12 Modify Password Click the Password the following UI will be opened Then and then enter the 4 characters as a connection password in the Password box the default is...

Page 23: ...y Co Ltd 23 30 VG05 DA 001 A 0 VG05 DA 001 A 0 4 13 Switch mode Click switch mode on the upper right corner the mode selection window will be openend Then you can choose iBeacon or Eddystone mode Defa...

Page 24: ...ansmit Power VG05 transmit power Advertise Interval VG05 advertise interval Battery Capacity VG05 battery Capacity Password VG05 connection password URL modify the Frame field information in Eddystone...

Page 25: ...chnology Co Ltd 25 30 VG05 DA 001 A 0 VG05 DA 001 A 0 4 15 Modify URL Click URL the following UI will be opened Then intput at most 16 characters as broadcasting URL Then click confirm to modify 4 16...

Page 26: ...Skylab M C Technology Co Ltd 26 30 VG05 DA 001 A 0 VG05 DA 001 A 0 Click Other setting the following UI will be opened The following three options are UID EID and TLM Select and set UID information...

Page 27: ...Skylab M C Technology Co Ltd 27 30 VG05 DA 001 A 0 VG05 DA 001 A 0 NameSpace 10 bytes and Instance 6 bytes are set respectively Select and set EID information...

Page 28: ...Skylab M C Technology Co Ltd 28 30 VG05 DA 001 A 0 VG05 DA 001 A 0 Set EID information maximum 8 bytes Select and set TLM information...

Page 29: ...C Technology Co Ltd 29 30 VG05 DA 001 A 0 VG05 DA 001 A 0 Select Encrypted TLM specification suggested and input encrypted TLM data at most 12 byte 16 bit Salt 2 byte and 16 bit Message Integrity chec...

Page 30: ...y Co Ltd Address 6 Floor No 9 Building Lijincheng Scientific Technical park Gongye East Road Longhua District Shenzhen Guangdong China Phone 86 755 8340 8210 Sales Support Phone 86 755 8340 8510 Techn...