 - USER GUIDE & DATA SHEET

WEIGHT & DIMENSIONS

UNIT DIMENSIONS & MASS

 (Approximate) 

SHIPPING DIMENSIONS & MASS

 (Approximate – Shrink Wrapped 

Model Number

SkyHydrant

MAX

  (SH1200)

SkyHydrant

GEM  

(SH600)

Model Number

SkyHydrant

MAX

  (SH1200)

SkyHydrant

GEM

  (SH600)

Height (cm)

143

82 

Depth (cm)

18

18

Width (cm)

25

25

Mass (kg-dry)

13

9

Mass (kg-wet)

32

21

Height (cm)

150

90

Depth (cm)

20

20

Width (cm)

28

28

Mass(kg-dry)

18

12

FILTRATE QUALITY

TERMINOLOGY

IMPORTANT OPERATING INFORMATION

Ppm 

Parts per Million

NTU 

Nephelometric Turbidity Units (a measurement of turbidity)

Um =  Micron
M =  Metre

•  The filter sub-modules located inside the SkyHydrant is to remain in a wet environment to avoid the 

membrane drying which would result in total and permanent loss of performance. If long-term storage is 
necessary after operation, the unit is to be rinsed with a solution of sodium hypochlorite (100ppm) and stored 
at a temperature not above 40˚C, out of direct sunlight.

•  When SkyHydrants are being used for the first time it is recommended that a chlorinated backwash be carried 

out before the filtrate is used.

•  The filter sub-module is resistant to oxidising agents such as chlorine, chloramines, bromine, bromamine, 

and potassium permanganate. Maximum exposure of sub-modules to bromine, bromamine, potassium 
permanganate, and other oxidants should be checked prior to starting operation.

•  The SkyHydrant comprises a single MEMCOR

®

 membrane sub-module located inside in a low-pressure 

housing. The unit is suitable for operation under low positive or negative head pressure. Raw water flows 
along the length of the hollow fibres before being forced through the walls of the fibre to produce a filtrate 
virtually free of suspended solids. The unit removes virtually all solids and bacteria and significantly 
reduces virus levels.   Filtrate flow rate is controlled manually.

Parameter

Bacteria

Virus

Coliform

Cryptosporidium

Parameter

Giardia

Algae

Turbidity

Log Reduction Value

>6 99.9999%

>3 

99.9%   

>6 99.9999%

>6 99.9999%

Log Reduction Value

>6 99.9999%

>6 99.9999%

<0.02

Summary of Contents for SkyHydrant-GEM

Page 1: ......

Page 2: ...TABLE OF CONTENTS Operating Instructions 01 How the SkyHydrant Works 04 How to Maintain Water Quality 06 Ultrafiltration Removal Criteria 08 Data Sheet 11 Operating Log 15...

Page 3: ...GEM Nominal 6 000 litres per day SkyHydrant MAX Nominal 12 000 litres per day Height 143 cm Depth 18 cm Width 25 cm Mass dry 13 kg Mass wet 32 kg Height 82 cm Depth 18 cm Width 25 cm Mass dry 9 kg Mas...

Page 4: ...nwind the head shaft a few turns anticlockwise to release pressure and remove the two temporary bolts used during shipping Next screw the two cleaning handles into the top of the SkyHydrant making sur...

Page 5: ...ulations of contaminate Do this by moving the cleaning handles on top of the unit back forth at least daily and throughout the day This is necessary to maintain the correct flow of drinking water and...

Page 6: ...al Clean follow Steps M1 to M8 After completion the unit can be returned back to producing drinking water again C1 C2 C3 C4 C5 C6 C7 C8 Solution Cleaning Using Citric Acid Undertake Monthly Citric aci...

Page 7: ...ying water directly to houses through a distribution network Never pump or connect mains water pressure directly to the ultrafiltration unit without using a suitable water pressure regulating or contr...

Page 8: ...oduced from the SkyHydrant can be stored in tanks and connected to taps or be piped to household supplies PERFORMANCE MONITORING At start up it is recommended the flow rate of the SkyHydrant be measur...

Page 9: ...d approximately 1 teaspoon of chlorine powder to 5 litres of water and flush through pipes or wash drinking water containers It is also recommended to regularly flush a chlorinated solution through th...

Page 10: ...event the growth of unwanted organisms and pathogens in the stored water To achieve this as a guide add about 3 4 teaspoon of chlorine powder at 65 available chlorine or 1 teaspoons of chlorine powder...

Page 11: ...ved TSS is similar to turbidity 4 IRON AND MANGANESE if first oxidised or if colloidal can be removed by ultrafiltration 5 ARSENIC MANGANESE if first oxidised can be removed by ultra iltration The Wor...

Page 12: ...alinity and salts are not removed by ultrafiltration include Salinity WHO safe drinking standard Max 250 mg L Chloride and Sodium WHO safe drinking standard Max 600 mg L Conductivity WHO safe drinking...

Page 13: ...YHYDRANT USER GUIDE DATA SHEET T4 T1 T2 STEP ONE STEP TWO CONNECT CONNECT HANDLES CONNECT LEGS WALL BRACKETS OPTIONAL U LT R A F I LT R AT I O N U N I T ACCESSORY KIT U L T R A F I L T R A T I O N U N...

Page 14: ...sources The treatment systems must provide pathogen free water economically and with minimal operator attendance SkyHydrant Water Filtration Units require no power or replacement filters and can be o...

Page 15: ...The secret to the successful operation of the SkyHydrant is the effectiveness of its patented backwash system which uses a mechanical agitation process to clean membrane surfaces Backwashing is initia...

Page 16: ...Feed Temperature Range Temperature Range for Tansportation and Storage Feed pH Range Maximum Housing Operating Pressure Membrane Module Details Materials of Construction Module Housing Assembly Valve...

Page 17: ...C out of direct sunlight When SkyHydrants are being used for the first time it is recommended that a chlorinated backwash be carried out before the filtrate is used The filter sub module is resistant...

Page 18: ...15 SKYHYDRANT USER GUIDE DATA SHEET TIME DATE DRINKING WATER PRODUCTION L MANUAL CLEANING UNDERTAKEN CHEMICAL CLEANING UNDERTAKEN AMOUNT CHLORINE USED OTHER INFORMATION OR NOTES OPERATING LOG...

Page 19: ...16 SKYHYDRANT USER GUIDE DATA SHEET...

Page 20: ......

Reviews: