SKYJACK, Page 9
Safety Rules
Section 1 - About Your Aerial Platform
Electrocution Hazard
This aerial platform is not electrically insulated. Maintain a Minimum Safe Approach Distance (MSAD) from energized
power lines and parts as listed below. The operator must allow for the platform to sway, rock or sag. This aerial
platform does not provide protection from contact with or proximity to an electrically charged conductor.
Per ANSI A92.6-2006 8.10(7)
“The operator shall perform only that work for which he or she is qualified, in compliance with all applicable
safety related work practices intended to prevent electric shock covered by the Code of Federal Regulations
(CFR) 1910.333. The operator’s level of competence shall be established only by persons qualified to do so.
Operators shall maintain the appropriate minimum approach distance (MAD) from energized power lines and parts
covered by CFR 1910.333 (c).”
Unqualified persons must maintain a minimum approach distance of 10 feet from any energized power line up to
50 kV. Energized power lines over 50 kV require a greater minimum approach distance to be maintained. Refer to
CFR 1910.333.
As per CSA B354.2-01
“The operator shall maintain the minimum safe approach distance (MSAD) from energized conductors at all times
in accordance with the authority having jurisdiction.”
As per AS 2550.1-2002
Elevating Work Platforms must remain 6.4 m from electrical distribution lines up to 133 kV and 8 m from transmission
lines greater than 133 kV. State regulations may take precedence over these approach distances.
DO NOT USE THE AERIAL PLATFORM AS A GROUND FOR WELDING.
DO NOT OPERATE THE AERIAL PLATFORM DURING LIGHTNING OR STORMS.
Voltage Range
Minimum Safe Approach Distance
(Phase to Phase)
(Feet)
0 to 300V
Avoid Contact
Over 300V to 50KV
10
Over 50KV to 200KV
15
Over 200KV to 350KV
20
Over 350KV to 500KV
25
Over 500KV to 750KV
35
Over 750KV to 1000KV
45
60023AD-ANSI
DANGER
FAILURE TO AVOID THIS HAZARD WILL RESULT IN DEATH OR SERIOUS INJURY!
Avoid Power Lines
Minimum Safe Approach Distance
ANSI/SIA A92.6-2006 & CSA B354.2-01 Requirements