SKYJACK, Page 20
February 2008
Mid Size & Full Size RT’s
Engine Powered
Section 2 - Operation
Component Identification
2.5-11 Folding Guardrail System
This system, when folded down, reduces the height
of the retracted aerial platform for transporting and
traveling through doorways only. Refer to
for guardrail folding procedure.
DETENT BALL
Clear of side of
pivot bracket
1
Correct position of locking pin
Figure 2-11. Guardrail Locking Pin
wARNiNG
The scissor assembly must be fully
lowered before raising or lowering the
guardrails.
wARNiNG
Before operating this aerial platform
check the guardrail system for loose
or missing locking pins. The guardrail
system must be upright and all pins must
be locked in place. Death or serious injury
could result if the guardrail system is not
upright or properly locked.
2.5-12 Lanyard Attachment Anchorage
Use this as an attachment point for safety belt/harness
tethers. Do not attach belts/harnesses to any other point
on the platform. Do not use this point to lift, anchor,
secure or support the platform or any other apparatus
or material.
Figure 2-12. Lanyard Attachment Ring
wARNiNG
The lanyard attachment anchorage
is used for travel restraint, within the
limits of the platform only. It is not a fall
arresting device! Used as such could
result in death or serious injury.
2.5-13 AC Outlet on Platform
This outlet is a source of 110V power on the platform.
Figure 2-13. AC Outlet on Platform