Main 720.328.3425 Fax:720.228.2400
Parameter address: 0x0005
Length (bytes): 32 (20 hex)
Default value is “SkyeModule
Nova
” (in hex)
Read/write
13.3.7
Host Interface Type
Identifier for the type of host interface being used.
Parameter address: 0x0006
Length (bytes): 1
Default value: 0x01 (TTL Serial)
Valid host interface values are:
o
0x01
–
TTL Serial
o
0x03
–
SPI
o
0x05
–
I
2
C
o
0x06
–
USB
o
Any other values are invalid and are ignored.
Read/write
13.3.8
Interface Baud Rate
Sets the baud rate of the host interface.
Works for the TTL Serial host interface only.
Parameter address: 0x0007
Length (bytes): 1
Default value: 0x02 (38,400)
Valid baud rate values are:
o
0x01
–
19200
o
0x02
–
38400
o
0x03
–
57600
o
0x04
–
115200
o
0x05
–
1 MBaud
o
Any other value
–
9600
Read/write
13.3.9
User Port Direction
Sets the direction of the GPIO pins of the reader.
Parameter address: 0x0008
Length (bytes): 1
Default value: 0x00
Default value is 0x00 (GPIO pins are outputs).
A one in the bit position indicates that the corresponding GPIO pin is an input.