background image

3inch Helical Rotor Pumps Series

- 1 -

Summary of Contents for 3SPC3.2/36-D36/400

Page 1: ...3inch Helical Rotor Pumps Series 1 ...

Page 2: ...ible Pump Performance 2 The 3SSH1 6 80 D36 400 Description 5 1 Model Instruction 5 2 Material of Parts 5 3 Performance Chart 5 4 Curve 6 5 Pump Performance 6 6 Pumps Outline Dimension 6 3 The SK 197K1500 36 Controller General Information 7 1 Features 7 2 The Technical Parameters of The SK 197K1500 36 Solar Controller 8 3 The operation mode of The SK 197K1500 36 Solar Controller 9 4 The Connect Way...

Page 3: ... not open or remove the front cover when operation Otherwise it may cause an electrical shock Before testing the pump must be installed can not make the pump dry run for a long time In order to test the pump the maximum dry run time is not more than 15s If the pump turning is reversed it can change any two lines of the pump s three power lines When the water pump is due to the light shadow it will...

Page 4: ... take water pumped to a reservoir for later use and water sources are those natural or special such as river lake well or waterway etc A float switch can be installed in the water tower to control the pump operation And install a low level probe in well to detect the well water so that when the water shortage pump is stopped Figure 1 shows a typical diagram of the pumping system The major parts an...

Page 5: ...oil Permanent Magnet Brushless DC Motor Without Hall Controller 32bit MCU FOC Sine Wave Current MPPT Controller Shell Die castAluminum IP67 Outlet Stainless Steel Pump Body Stainless Steel Motor Body Stainless Steel Bear NSK Helical Rotor 316 Stainless Steel Screw 316 Stainless Steel Cable 3 Meters Three core copper cable 1 5mm3 2 3 Performance Chart Item Parameter Values 1 Rate Voltage 36VDC 2 Ra...

Page 6: ...rve TOTAL HEAD H m FLOW RATE m3 h Figure2 Pump Curve 2 5 Pump Performance Model Power W Voltage Vdc Max Flow m3 h Max Head M Outlet in Outline in 3SSH1 6 80 D36 400 400 36 1 6 80 0 75 3 2 6 Pumps Outline Dimension Figure3 outline Dimension 6 ...

Page 7: ...with auto reversing torque High Voltage Surge Low Input Voltage Open motor circuit Short circuit Over heat NOTE This controller provides motor overload protection by preventing motor current from exceeding rating current and by limiting the duty cycle in the event of low water level This controller does not provide over temperature sensing of the motor System Diagnostics The SK 197K1500 36 solar p...

Page 8: ...oller is optional not mandatory 3 2 The Technical Parameters of The SK 197K1500 36 Solar Controller Item Technical Parameters Voltage Rate Voltage 36 VDC Max Open Voltage 80 VDC Under Protection Voltage 17 VDC Over Protection Voltage 68VDC Current Rate Current 12A Over Protection Current 15A Peak Protection Current 18A MCU and Controller Mode 32bit MCU FOC Sine Wave Current MPPT Shell Die cast Alu...

Page 9: ...e run with the lowest speed The display the run with the highest speed Power Connect to Power display Running Pump is Running display Nate1 MPPT Controller running with MPPT Function display Well Without water in the well display Tank Pull water in the Tank display MPPT Maximum Power Point Tracking When the controller Power ON The system Auto work with MPPT MPPT FUNCTION SETTING When the light Pus...

Page 10: ...p TL and TH open circuit The pumps run WL and COM short circuit The pumps stop WL and COM open circuit The pumps run Nate when the WL and COM from short to Open the pumps will delay 10min to run U V W Connect to Pumps Solar Energy Plate Connection Method 3 4 2 The operation of The Tank Level Switches 1 PumpRunning 2 PumpRunning 3 PumpStopping 4 PumpStopping 5 PumpRunning 10 ...

Page 11: ...itches 3 4 4 The operation of Well Level Switches 1 The pumps RUNNING the Switches OFF 2 The pumps STOPPING the Switches ON 3 The pumps will delay 10min to RUNNING the Switches from ON to OFF The Pressure Switches ON The pump STOP The Pressure Switches OFF The pump RUNNING 11 ...

Page 12: ...d Connection way 4 1 Configured by 18Vmp Voc 22V Solar Panel INPUT Solar Panel Vmp 18Vdc Solar panel VOC 22Vdc Solar panel Power 150W Solar panel Quantity 4PCS OUTPUT Vmp 36Vdc VOC 44Vdc Power 600W MAX 4 2 Configured by 30Vmp Voc37V Solar Panel INPUT N A OUTPUT 12 ...

Page 13: ...ical Rotor Pumps Series 4 3 Configured by 36Vmp Voc44V Solar Panel INPUT Solar Panel Vmp 36Vdc Solar panel VOC 44Vdc Solar panel Power 300W Solar panel Quantity 2PCS OUTPUT Vmp 36Vdc VOC 44Vdc Power 600W MAX 13 ...

Page 14: ...ture high temperature may cause the controller stop to protect itself 2 Location Selection The SK 917K Series solar pump controller is intended for operation in ambient temperatures up to 60 but in order to avoid overheating caused by the failure it is recommended to install the controller in the shadow position The SK 917K Series solar pump controller must be installed into a control box which ha...

Page 15: ...550 550 36 3 2 54 1 3 3SPC3 2 80 D54 750 750 54 3 2 80 1 3 3SPC3 3 106 D72 1100 1100 72 3 3 106 1 3 4SSH3 0 80 D48 650 650 48 3 80 1 4 4SSH3 6 100 D72 1000 1000 72 3 6 100 1 4 4SSC4 2 25 D36 300 300 36 4 2 25 1 5 4 4SSC4 0 42 D36 500 500 36 4 0 42 1 25 4 4SSC6 0 58 D60 750 750 60 6 0 58 1 5 4 4SSC3 6 138 D72 1000 1000 72 3 6 138 1 25 4 4SSC5 2 110 D72 1000 1000 72 5 2 110 1 5 4 4SSC15 38 D72 1000 ...

Reviews: