Sky Control SC2100 Configuration Manual Download Page 42

Setting up CAN

CAN bus is used for connection of CAN sensors 

and CAN modules.  The device has two inde-

pendent CAN nodes: CAN1 and  СAN2.

Before using CAN sensor module, CAN bus must 

be configured in order to operate with this CAN 

sensor module. Configuration of the CAN bus is 

The following operations can be carried out on 

CAN bus node:

 

Refresh

 - updates the current information 

on the status of the node;

 

Config - launches configuration process of 

the node for CAN sensor modules con-

nected to it, the old configuration is lost;

 

Delete

 - removes selected CAN sensor 

module from the configuration (list) of CAN 

sensor modules;

 

Apply

 - saves the list of CAN sensor mod-

ules in flash memory;

 

Restart

 - restarts the CAN bus node.

To set up a CAN bus node for operation  with 

the CAN sensor module, connect CAN module 

to CAN network and run corresponding con-

figuration procedure in the web-interface using 

command Config. The configuration process 

is displayed at the bottom of the tab and lasts 

made through tab “Preferences” >> “CAN con-

fig”, which in turn has two identical tabs - one 

for each node.

E

ach station tab contains current information on 

the status of the node and a list of  CAN sensor 

modules connected to this node.

aprox. 2 minutes.   Detected modules will be 

added to the list of modules during the configu

-

ration process. After completing configuration 

the node returns to its normal operation.  Sen-

sors of detected CAN modules are added to the 

tree of elements. 
The names of the sensors are automatically set 

in the form {module name}{serial number}-

{type of sensor} and can be edited.
If you need to remove CAN sensor module from  

the configuration list use command Delete, then 

use command Apply to apply the changes you 

made and restart the node using command 

Restart.

40

Quick Configuration

Summary of Contents for SC2100

Page 1: ...IP Monitoring systems SC8100 SC8110 SC2100 SC2110 Configuration manual ...

Page 2: ......

Page 3: ...ator account username and password User access Settings recovery Password recovery Interface overview Network settings Determination of IP address Setting up time Time zone Time synchronization Creating floor map plan Sensor configuration Creating groups of elements Creating notifications Notification via E mail Notification via SNMP Trap Notification via SMS Macros in the notification text Front ...

Page 4: ...odem SMS notifications SMS commands Sending SMS from PC Setting up CAN Setting up dynamic DNS 34 35 35 35 37 37 40 41 Description HTTP upgrade FTP upgrade Upgrade via USB Restoring an appliance Disposal Battery replacement Fuse replacement Cleaning Upgrade and restore options Warranty Cleaning battery fuse disposal and replacement 42 42 42 43 43 45 45 45 46 47 Warranty period 02 ...

Page 5: ...on module SC408 and how to mount and use embedded modules SC16 SC920 After performing configuration proce dures described in this manual you can access the system from Firefox Safari and Chrome browser perform additional configuration tasks and begin to monitor the environment Analog sensors Current loop converter 4 20 mA SC420 Temperature sensor SC500 Outdoor temperature sensor SC501 Related docu...

Page 6: ...n sensor SC540 Vibration sensor SC541 Chain con nection possible Smoke sensor SC560 Chain con nection possible PIR sensor SC570 Analog sensors Leak sensor SC590 Cable leak sensor SC591 CAN modules Airflow and tempera ture unit SC450 Analogue sensor mod ule SC408 Analogue CAN 04 Introduction ...

Page 7: ...Embedded modules Dry contacts unit SC16 GSM modem SC920 CAN sensors PIR vibration tem perature CAN sensor SC470 Smoke humidity and temperature CAN sen sor SC460 05 Introduction ...

Page 8: ...S Linux 2 6 38 RAM 64Mb ROM 128Mb FLASH Software Built in software for events processing Alert types FTP Syslog SMTP or SNMP SMS GSM modem is ordered separately Pings Built in function for ping LEDs 4 green ACT CN1 CN2 ERR LEDs latching relais 4 4 8 Clock Built in clock with time synchronization Watchdog Built in watchdog timer Power SC8100 SC8110 SC2100 SC2110 SC1108 Power input 12V Fuse at the i...

Page 9: ...nsing Storage humidity 0 to 95 non condensing Other Features SC8100 SC8110 SC2100 SC2110 SC1108 Installation 19 19 Desktop 19 19 Dimensions L x W x H in mm 440 44 75 440 44 75 215 44 65 440 44 65 440 44 85 Weight 1 5 kg 1 5 kg 1 2 kg 1 2 kg 1 8 kg Scalability modules are ordered separately SC8100 SC8110 SC2100 SC2110 SC1108 Extension modules SC408 SC450 Allows to increase the number of sensors in ...

Page 10: ...modules connect in a chain Fuse protection on each line Air flow heat sensors Response time 2 min recovery time 1 min Temperature measurement range 40 100 C accuracy 2 C Other Features SC408 SC450 Installation At the bottom there are four mounting holes for mounting screws Dimensions L x W x H in mm 110 68 40 86 48 25 Weight 0 6 kg 0 6 kg Extension modules All Sky Control main master modules allow...

Page 11: ... connect a USB camera or to restore an appliance 4 Reset resets the appliance 5 SD SD card connector with ejector needed to store data 6 LEDs ACT indicates appliance status CN1 indicates CAN1 bus traffic CN2 indicates CAN2 bus traffic ERR indicates error and traffic 7 CAN two equivalent digital connectors RJ12 for the connection of CAN sensors and CAN extensions on a CAN bus with auto sensing 8 TR...

Page 12: ... 11 Outputs 1 4 4 relays status indicators 12 1 Wire RJ9 connector for 1 Wire Proximity type or I touch readers with auto sensing 13 SMA connector used when GSM mo dem is installed inside of the appliance to connect GSM antenna 14 PWR for connection of external power 12V Internal input Back panel SC8100 Back panel SC8110 Back panel SC2110 10 Physical description ...

Page 13: ... RLY1 RLY4 4 relays output connec tors The relays maximum power output 5A 240V 19 DC 12V backup power socket to con nect a battery or a battery backup Back panel SC450 Back panel SC2100 Back panel SC408 11 Physical description 20 Dry contacts empty slot for dry con tacts module SC16 used to connect dry contacts on doors windows etс 21 Fan sensors 1 6 Inputs for airflow sensors ...

Page 14: ...ntory Inventory Master module SC8100 SC8110 SC2100 SC2110 Extension module SC408 SC450 19 rack brackets 2 pcs SC8100 SC8110 SC2110 M3 x 8 Phillips flat head screws 6 pcs SC8100 SC8110 SC2110 Inventory 1 8 m EU Schuko C13 power cord SC8100 SC8110 SC2110 1 8 m IEC C13 C14 power cord SC8110 RJ45 1m patch cable SC8100 SC8110 SC2100 SC2110 USB miniUSB cable SC8100 SC8110 SC2100 SC2110 RJ11 6P4C 2m CAN ...

Page 15: ...C8110 SC2100 SC2110 Warranty card SC8100 SC8110 SC2100 SC2110 Self adhesive rubber foot 4 pcs SC8100 SC8110 SC2100 SC2110 SC408 SC450 Inventory Backup battery 3 5mm terminal plug SC8100 SC8110 SC2100 SC2110 12V adapter SC2100 SC408 SC450 Dry contacts board embedded module SC16 M3 5mm bolts 3pcs SC920 SC16 BH10 cable SC16 GSM modem SC920 embedded module SC920 13 Package content ...

Page 16: ...Inventory Antenna SC920 Antenna wire with spac ers SC920 BH16 cable SC920 Airflow sensor TS1 2 pcs SC450 Relay terminal plugs 3 pcs SC16 14 Package content ...

Page 17: ...nt temperature corresponds to the values listed under Specifications Keep in mind that the temperature of the unit increases in cramped conditions please keep track of the temperature on the internal temperature sensor Try to install the unit in such a way as to allow for normal air circulation required for the normal functionality of the unit To avoid equipment damage fasten all the screws all th...

Page 18: ...alog sensor by a supplied RJ 11 6P4C cable to any of 8 analog ports A1 A8 Determination of the sensor type and connec tion will occur automatically This procedure applies to the following sensors which are supported by the appliance and are connected to the analog ports Type Analog sensors Current Loop transceiver SC420 Temperature sensor SC500 Outdoor temperature sensor SC501 Humidity sensor SC51...

Page 19: ...sen sor One chain can have up to 10 sensors CAN sensors and CAN modules connection Connect CAN sensors to any CAN port CN1 or CN2 on the monitoring system using a CAN FTP cable supplied CAN sensors can also be connected to the port of another CAN sensor or CAN module which are connected on the CAN bus Determination of the module and its con nection is done through web interface 17 Installation Thi...

Page 20: ...ll mounting Dimensions for wall mounting General connection diagram p 19 SC450 airflow and temperature unit installation Connecting 1 Wire reader I Touch or 1 Wire Proximity readers can be con nected to the port 1 Wire using RJ9 4P4C connector The reader is determined automati cally Only SC8100 and SC8110 have 1 Wire port Check the PCB DIP switch 2 should be in ON position 18 Installation ...

Page 21: ...ata wire of I BUTTON reader is connected to the BUS contact on RJ9 connector Connecting Proximity reader Proximity readers have 3 wires 1 Power 12V 2 Ground GND 3 Data wire BUS Proximity reader s GND is connected to the GND pin on RJ9 connector Proximity reader s data wire is connected to the BUS contact Proximity reader s power connects to the 12V pin on RJ9 connector ...

Page 22: ...elay terminal plug the load to the left 1 or right 3 clamps of the plug Insert the plug into the relay socket terminal RLY1 RLY4 By command relay will switch on or off the load The maximum pos Connecting the load to SC8100 To connect an external load сonnect power cable from the load to the output Output 1 4 of the appliance By command relay will switch on or off the load Do not insert the termina...

Page 23: ...ve the possibility to install Dry Contacts module It is a device mounted and connected inside of master unit Can be used together with any contacts for example with door or window contacts circuit breakers etc Inventory Components Dry contacts board BH10 cable Relay terminal plugs Screw M3 5mm 21 Installation Allows to control 16 dry contacts ...

Page 24: ...eves 4 Connect 16 wire BH16 flat cable sup plied with dry contacts module to the connector on the module card and on the appliance motherboard Close and fasten the cover 5 Check if all the cables are connected Carefully place top cover back so that all cover wings fit in and all cutoff points match the panel holes Then use 3 screws to close the enclosure Check whether the burrs prevent dry contact...

Page 25: ...rnet for sending SMS notifications and SMS commands 23 Installation Inventory GSM board Antenna Antenna wire BH16 cable M3 5mm bolts 3pcs Inventory Installation To install and to connect extension units switch off appliance unplug from the out Antenna GSM or Dry Contacts module are installed inside Carefully open the let or disconnect the power connector box by unplugging if necessary any cables t...

Page 26: ...connector gold plated washer and nut from the supply holding SMA con nector with one key securely tighten the nut with the other key 5 Connect 16 pin flat cable to the connectors on the modem card and on the appliance motherboard Close and fasten the cover If necessary install the SIM card into the appropriate hole 3 4 6 Carefully place top cover back so that all cover wings fit in and all cutoffp...

Page 27: ...em Connecting USB camera If necessary by means of supplied cable USB A MiniUSB AB you can connect any USB camera of class Linux UVC Webcam which supports MPEG USB camera is connected to HS port Determination of camera and connection will occur automatically USB camera can also be connected to USB A port however it will have a lower resolution Do not use any USB exten sion cables when connecting th...

Page 28: ...nt switched off 2 Hostname skycontrol 3 IP address 192 168 0 193 4 Network mask 255 255 255 0 5 Broadcast 192 168 0 1 6 Gateway 192 168 0 255 7 Primary DNS 192 168 0 1 To start working with the appliance your PC must be in the same network as the new appliance To do this please set up on your PC subnet mask 255 255 255 0 and IP address 192 168 0 XXX where XXX number from 0 to 192 from 194 to 254 a...

Page 29: ...e and edit notifications Timers Create and edit timers Pings Create and edit pings IP cameras Create and edit IP cameras System set tings Manage interface settings Download backup Backup device settings Synchronize time Set and synchronize system time Reboot System reboot Logic schemes Create and edit logic schemes System log Clear log Access control Manage user access permissions Serial Com ports...

Page 30: ...l view of the interface is shown below 28 Initial Configuration USB and wait The update process is displayed on the front panel with flashing LED ERR If successful the ERR LED will go off and ACT LED will blink for a while with increased frequency If unsuccessful ERR LED will remain lit Remove USB flash drive and reboot the system Test the appliance 2 Tab Floor map Cameras panel For pictures trans...

Page 31: ...29 Initial Configuration ...

Page 32: ...b Pref erences Network Change the network settings to the needed values and click Save Setting up time Available network device settings Enable DHCP Enable or disable DHCP connection Hostname Host name of the device IP address IP address of the device Network mask Netmask Broadcast Broadcast address Gateway Default gateway Primary DNS Primary DNS System time in the panel Sytem info corresponds wit...

Page 33: ...ick on the icon select Delete Sensor configuration To configure a sensor click on the sensor ele ment in the tree or on the sensor icon in the toolbar You can view or edit parameters of sen sor in the window Properties in the bottom left corner of the interface You can change the size of the window by dragging it with your mouse Change the needed settings and click Update at the bottom of the Prop...

Page 34: ...face select the needed element In the dialog box specify a group name fill in the description and press Save Left click on the menu item Fill in the form in the window that appears and press Save To test the notification you can press Send test message It is possible to add the following notification via E mail Add Mailer Email notification via SNMP trap Add Mailer SNMP trap notification via SMS A...

Page 35: ... e g 25 or 465 Login Password SMTP server username and password Mail from Sender s e mail address sky25test gmail com Mail to Recipient s e mail address sky25test gmail com Message Text of the message Parameter Description Name The name of the element in the system SNMP server Name or SNMP server IP address 192 168 1 10 SNMP port SNMP port usually 162 Community Community name public Version Versio...

Page 36: ... System time 3 Creating ping Ping is a utility used to test the reachability of a host an a network In the absence of connection ping registers from a normal state to a state of alarm After you restore the connection ping Creating timer Timer allows you to plan the events in the sys tem When timer is triggered it goes from the normal state into alarm state When timer is turned off it goes back to ...

Page 37: ... go to Preferences select Logic schemes and click on the item Add Edit Deactivate or Delete When editing or adding a logic scheme specify the logic scheme name Create a set of conditions IF Select name of element in Element and state of element in State as a condition for logic To add an additional condition use AND or OR in the field Operator If a sensor with an analog output changes its state ve...

Page 38: ...K Bring the key next to Proximity reader or touch the reader with the key New key will be regis tered and dialog box will disappear Default key name newkey can then be edited If the key is not registered or you have decided not to register the key click OK Access control 2 Create E mail and SMS notifications Follow the steps in section Creating notifi cations 3 Go to Preferences Select Logic schem...

Page 39: ...dem is used to send sms notifications and to receive sms commands warning occurence of a one time error that does not affect the overall operation of the GSM modem alarm occurence of error that does not allow further operation of GSM modem Network status network status registered in Operator registered in network Operator registered registered in network not registered not registered in home netwo...

Page 40: ...nsors control relays or outlets Phone numbers from which the SMS com mands will be sent should be added to the list of allowed numbers in the modem properties Right click on modem icon Edit GSM modem Allowed numbers In response to each SMS command a response SMS will be sent In case of an error an SMS will be sent with information about the error and an example of command An SMS can contain only o...

Page 41: ...ending SMS from PC You can use an external program to send SMS directly from your PC An example of such program and example of code in C can be found here ftp ftp sky control com drivers sms The zip file Adobe AIR contains application and an example of code in C To follow the example please use the following command in console gcc O2 o sendsms sendsms c To send SMS you can use a free software such...

Page 42: ...CAN module to CAN network and run corresponding con figuration procedure in the web interface using command Config The configuration process is displayed at the bottom of the tab and lasts made through tab Preferences CAN con fig which in turn has two identical tabs one for each node Each station tab contains current information on the status of the node and a list of CAN sensor modules connected ...

Page 43: ...ng device Preferences Network Select Enable DynDNS Select service No ip www no ip com type in Login Password and Hostname which you put in no ip com Save settings Save The device should update the IP address for the Hostname host after 1 minute You can check this in the no ip com service After some time the service will match IP address and Hostname Using the Hostname in the browser open the web i...

Page 44: ... version 2 03 to 2 1 0 logic schemes and sensor parameters are lost To clear browser history in Mozilla Firefox follow Tools Clear Resent History To clear browser history in Google Chrome follow Settings History Clear All Brows ing data To clear browser history in other browsers see browser help section To update the software via interface HTTP go to folder System menu in the web interface select ...

Page 45: ...r ences will be destroyed forever if a full software recovery is used Attention Subfolder C extract firmware must contain firmware zip file If the appliance has a GSM modem it must be turned off disconnect modem cable from modem connector J5 Close the cover of appliance turn the power on connect cable USB A miniUSB port to PC USB input and NS input of appliance The PC will detect the new USB devic...

Page 46: ...f the appliance has GSM modem con nect modem cable back to modem connector J5 Close the cover turn the power on and test the system Attention Before starting operation make sure you press the appliance Reset button or turn on off the power otherwise the program will not be able to connect appliance Disconnection and connection of con nector labeled J5 Modem should be performed only when the power ...

Page 47: ...evice without power supply for a long period of time or when using the device after a long period of no use or when using after the warranty period has expired Battery replacement is only possible when the power is turned off on the device In order to do this open the enclosure carefully push aside the old battery and remove it Check the place of battery installation for the absence of water stain...

Page 48: ...damage the parts 46 Cleaning disposal replacement 3 If the fuse holder is cold then put it in a warm place for some time if you have such possibility 4 When it warms up remove the fuse by hands or pushing it out with a screwdriv er and insert a new fuse Then return the fuse holder in place Cleaning Use a soft dry cloth to clean the appliance ...

Page 49: ...date of original purchase or the rated life of the unit depending on which will end sooner Warranty is included in the appliance inventory Please carefully read the terms of the war ranty Save your warranty and the documents of sale in a safe place These documents will be required for exercise of warranty service 47 Warranty ...

Page 50: ......

Page 51: ......

Page 52: ...wiki skycontrol com forum skycontrol com Documentation Support www skycontrol com ...

Reviews: