Loss of more than one-third of the original diameter of the outside wires due to abrasion, corrosion,
scrubbing, flattening, or peening.
Heat damage caused by a torch, or any damage caused by contact with electrical wires.
Damage caused by improper grounding when welding from a suspended platform.
Evidence that the secondary brake has been activated during an over speed condition and has
engaged the suspension rope.
Examples of wire rope defects that require the rope to be replaced
Broken or damaged tips
Broken strands
Crushing
Kinking
“Milking”
Heat, Chemical or Electrical damage
Bird caging