Skuttle Indoor Air Quality Products Compustat SEH-7100-000 Safety And Installation Instructions Manual Download Page 3

 
 
NOTE: 

The humidifier control will operate properly with either a switched or continuous power source. Whether you are using 
accessory terminals or an external transformer, a minimum 

10 VA

 is required 

 

S

TEP

 9:

  

Connecting to the Humidifier 

Strip the wires used for all the humidifier control terminal connections 1/4".  
 

If furnace accessory terminals are used

, wire the solenoid valve directly to the “Out” terminals on the humidifier con-

trol. Also attach a jumper wire to the Wire Connector, as shown in Figures 6 and 7. Do not use a Model A50 relay.  

NOTE: 

See the furnace manual for operation of accessory terminals.  

 

If an external transformer is used

, connect a Model A50 relay in series with the solenoid valve and the “Out” terminals 

on the humidifier control. This will allow the humidifier to operate only when the furnace blower is on. (See Figure 6-8 to 
determine the correct wiring for your model humidifier).  

 
 
 

MODELS 

2000 
2001 

55 

MODELS 

45 
86 
90 

190 

Figure 8 

MODELS 

60 

2002 

Figure 6 

Figure 7 

 

 

Summary of Contents for Compustat SEH-7100-000

Page 1: ...a heat call is satisfied to prevent high temperatures from damaging the control Do not set the humidity so high that condensation forms on windows or walls Indoor condensation may result in damage to the home These instructions are for installation of the Skuttle Compustat humidifier control only For installation of a Skuttle humidifier refer to the instructions packaged with the humidifier STEP 1...

Page 2: ...Compustat for Manual Operation STEP 6 Route the Sensor Wire to the Selected Location Run wire between the humidifier control and the outdoor sensor lead If the sensor is out doors snap the probe end of the sensor into the sensor shield and attach it to an exterior wall The probe must be completely covered by the shield NOTE The outdoor temperature sensor wire must not exceed 30 feet in length CAUT...

Page 3: ...he Out terminals on the humidifier con trol Also attach a jumper wire to the Wire Connector as shown in Figures 6 and 7 Do not use a Model A50 relay NOTE See the furnace manual for operation of accessory terminals If an external transformer is used connect a Model A50 relay in series with the solenoid valve and the Out terminals on the humidifier control This will allow the humidifier to operate o...

Page 4: ... Guide below 5 Set the humidifier control If the home is occupied set the humidifier control knob to 5 For manual operation set the knob to 35 If the home is vacant turn the humidifier control knob counterclockwise 4 to Off 6 Tell the homeowner to refer to the Compustat Operating Instructions for direction regarding initial adjustment Troubleshooting Guide applies to automatic and manual operation...

Page 5: ...e verify that the humidifier will shut off after approxi mately one minute Check the resistance of the sensor See previous section For automatic applications Make sure the outdoor temperature sensor is mounted completely outside the house i e not recessed into the hole on the North Northeast or North west side away from direct sunlight Turn the humidifier control knob counterclockwise 4 to the Off...

Page 6: ...101 Margaret Street Marietta OH 45750 Phone 800 848 9786 Fax 740 373 9565 Email customerservice skuttle com Web www skuttle com ...

Reviews: