![Skov DOL 53X Technical User Manual Download Page 6](http://html1.mh-extra.com/html/skov/dol-53x/dol-53x_technical-user-manual_1289296006.webp)
6
Technical User Guide
DOL 53X/DOL 63X Upgrade Kit from DOL 234F
2.2 Electric Connection
Qualified personnel in accordance with the applicable national and international standard EN
60204-1 and any other EU standards that are applicable in Europe must perform installation,
service and fault finding of al electrical equipment.
The installation of a supply isolator is required for each motor and power supply, so maintenance
of electrical equipment can be carried out in a dead environment. Supply isolator is not supplied
by SKOV A/S.
2.3 Replace panel with CPU Module
Before
After
1)
Disconnect power to the computer.
2)
Remove the screws (
A
) and loosen the panel with CPU module.
3)
Remove the flat cable (
B
).
4)
Mark wires for the power supply (
C
) and remove them.
5)
Remove the connector for the power supply (
C
)
6)
Remove screws for the power supply (
C
) and remove them.
7)
Mount the new power supply with four screws and connect the connector.
8)
Connect the flat cable from the CPU module (
B
).
9)
Load system software, see
Technical User Guide, Loading System Software
.
10)
Mount the screws (
A
).
If no changes are made to the settings/installation, the jumpers on the main modules should not be moved. If changes are
made, the installation must be made as shown in the menu
Show installation
.
2.4 Make Setup and Connection of DOL 53X / DOL 63X
1)
Switch the power to the computer on.
2)
Make the setup of DOL 53X / DOL 63X in accordance with the noted settings from DOL 234F.
3)
Make the settings in DOL 53X / DOL 63X
Technical /
Setup / Installation
based on the settings noted from
DOL 234F.