4.5 Adjusting the jumper and connection in the winch motor
Set the jumper on the PCB to give actuator the desired
function.
LED indication
OK = slow flashing
Error = quick flashing (10 times/second)
H1 Actuator controller or +24 V DC supply
H2 Actuator controller
H3 0 V
H6 +24 V DC supply
H7 0-10 V position feedback
H8 0 V
H9 Open collector (transistor output) is used for fan with motor
controller.
H10/11a and H12a relay output is used for fan without motor